12.07.2015 Views

walsall Explosion Protected Electrical Equipment

walsall Explosion Protected Electrical Equipment

walsall Explosion Protected Electrical Equipment

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

EEx e and EEx i Terminal Boxes - Stainless and Mild SteelType FXL4 -380mm x 260mm x 150mm or 200mmEEx e and EEx i Terminal Boxes - Stainless and Mild SteelType FXL5 - 458mm x 382mm x 150mm or 200mmEEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 ATEX/GOST/ULEEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 ATEX/GOST/ULHAZARDOUS AREA SPECIFICATIONHAZARDOUS AREA SPECIFICATIONMarking to 94/9/ECType of protectionTemperature classArea classificationCertification NosIngress protectionPower dissipationII 2 GD, II 1 GD T6,T5,T4,T3EEx e II and EEx ia IICT6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C)Zones 0,1,2,21,22. Groups IIA, IIB, IICSira 99ATEX3199 and Sira 00ATEX3027UGOST ‘R’ POCC GB. гБ05.BO1131IP66,67 to EN60529:1992Maximum 21 Watts. Except for dust applicationswhere the maximum is 10.5 WattsMarking to 94/9/ECType of protectionTemperature classArea classificationCertification NosIngress protectionPower dissipationII 2 GD, II 1 GD T6,T5,T4,T3EEx e II and EEx ia IICT6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C)Zones 0,1,2,21,22. Groups IIA, IIB, IICSira 99ATEX3199 and Sira 00ATEX3027UGOST ‘R’ POCC GB. гБ05.BO1131IP66,67 to EN60529:1992Maximum 29 Watts. Except for dust applicationswhere the maximum is 14.5 WattsENCLOSURE SPECIFICATIONENCLOSURE SPECIFICATIONDimensionsMaterial boxMaterial gland plateFinishWeight emptyCover fixingGasketEarthingSecurityEntriesMounting380mm x 260mm x 150mm or 200mm1.5mm 316L, (1.4404) stainless steel or mild steel2.5mm 316L, (1.4404) stainless steel or mild steelStainless steel – electropolishedMild steel – Powder coated RAL 70326.5Kg and 7.0KgFully detachable hinged cover with captive M6 stainlesssteel hexagon head slotted screwsOne piece fire resistant closed cell neoprene for Ta -40˚COne piece silicon rubber for Ta -50˚C10mm brass internal/external earth stud as standardOptional earth stud welded to coverOptional earth stud welded to gland platePadlockable haspVia gland plates 1-4 or direct through bodyExternal lugs with 10mm clearance holesAll Dimensions in mmReturn flange sealingDimensionsMaterial boxMaterial gland plateFinishWeight emptyCover fixingGasketEarthingSecurityEntriesMounting458mm x 382mm x 150mm or 200mm1.5mm 316L, (1.4404) stainless steel or mild steel2.5mm 316L, (1.4404) stainless steel or mild steelStainless steel – electropolishedMild steel – Powder coated RAL 703210Kg and 11KgFully detachable hinged cover with captive M6 stainlesssteel hexagon head slotted screwsOne piece fire resistant closed cell neoprene for Ta -40˚COne piece silicon rubber for Ta -50˚C10mm brass internal/external earth stud as standardOptional earth stud welded to coverOptional earth stud welded to gland platePadlockable haspVia gland plates 1-4 or direct through bodyExternal lugs with 10mm clearance holesAll Dimensions in mmReturn flange sealingVerticle RailsHorizontal RailsORDERING INFORMATIONMaterialStainlessMild SteelStainlessMild SteelStainlessMild SteelStainlessMild SteelStainlessMild SteelA GUIDE TO PHYSICAL TERMINAL CAPACITYWDU 2.52x602x43GLAND PLATE OPTIONS Product Code (150mm deep) Product Code (200mm deep)NumberLocation EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal BoxFXLS410 FXLS420 FXLS430 FXLS410D FXLS420D FXLS430DFXLM410 FXLM420 FXLM430 FXLM410D FXLM420D FXLM430DFXLS411 FXLS421 FXLS431 FXLS411D FXLS421D FXLS431DFXLM411 FXLM421 FXLM431 FXLM411D FXLM421D FXLM431DFXLS412 FXLS422 FXLS432 FXLS412D FXLS422D FXLS432DFXLM412 FXLM422 FXLM432 FXLM412D FXLM422D FXLM432D0011223344WDU 4WDU 6 WDU 102x49 2x36 2x292x35 2x26 2x20Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded--BBABABBCDBCDABCDABCDEnclosure SizeGland Size mmSide A+BSide C+DA GUIDE TO ENTRY CAPACITY FOR GLAND PLATES*FXL4FXL4D20 25 32 20 25 3217 10 5 27 15 1118 12 6 28 15 11* More entries are available if direct entry is usedFXLS413 FXLS423 FXLS433 FXLS413D FXLS423D FXLS433DFXLM413 FXLM423 FXLM433 FXLM413D FXLM423D FXLM433DFXLS414 FXLS424 FXLS434 FXLS414D FXLS424D FXLS434DFXLM414 FXLM424 FXLM434 FXLM414D FXLM424D FXLM434DVerticle RailsHorizontal RailsORDERING INFORMATIONMaterialStainlessMild SteelStainlessMild SteelStainlessMild SteelStainlessMild SteelStainlessMild SteelA GUIDE TO PHYSICAL TERMINAL CAPACITYWDU 2.53x813x66GLAND PLATE OPTIONS Product Code (150mm deep) Product Code (200mm deep)NumberLocation EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal BoxFXLS510 FXLS520 FXLS530 FXLS510D FXLS520D FXLS530DFXLM510 FXLM520 FXLM530 FXLM510D FXLM520D FXLM530DFXLS511 FXLS521 FXLS531 FXLS511D FXLS521D FXLS531DFXLM511 FXLM521 FXLM531 FXLM511D FXLM521D FXLM531DFXLS512 FXLS522 FXLS532 FXLS512D FXLS522D FXLS532DFXLM512 FXLM522 FXLM532 FXLM512D FXLM522D FXLM532D0011223344WDU 4WDU 6 WDU 103x67 3x50 3x393x55 3x40 3x33Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded--BBABABBCDBCDABCDABCDEnclosure SizeGland Size mmSide A+BSide C+DA GUIDE TO ENTRY CAPACITY FOR GLAND PLATES*FXL5FXL5D20 25 32 20 25 3227 17 9 40 24 1727 17 9 40 24 17* More entries are available if direct entry is usedFXLS513 FXLS523 FXLS533 FXLS513D FXLS523D FXLS533DFXLM513 FXLM523 FXLM533 FXLM513D FXLM523D FXLM533DFXLS514 FXLS524 FXLS534 FXLS514D FXLS524D FXLS534DFXLM514 FXLM524 FXLM534 FXLM514D FXLM524D FXLM534DOptional Extras6mm earthing stud welded to cover<strong>Equipment</strong> mounting plate, mild steel powdercoatedBrass padlock with 2 keys10mm internal/external stainless steel earth studCES6XL4MPBP2SSETOptional Extras6mm earthing stud welded to gland plateRain canopyDocument walletGPS6XL4RCXL4DWOptional Extras6mm earthing stud welded to cover<strong>Equipment</strong> mounting plate, mild steel powdercoatedBrass padlock with 2 keys10mm internal/external stainless steel earth studCES6XL5MPBP2SSETOptional Extras6mm earthing stud welded to gland plateRain canopyDocument walletGPS6XL5RCXL5DW21 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 sales@<strong>walsall</strong>-ltd.com www.<strong>walsall</strong>-ltd.comtel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 sales@<strong>walsall</strong>-ltd.com www.<strong>walsall</strong>-ltd.com 22

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!