12.07.2015 Views

Exhibits J, Grade Crossings Standards Manual - Metrolink

Exhibits J, Grade Crossings Standards Manual - Metrolink

Exhibits J, Grade Crossings Standards Manual - Metrolink

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

FLASHING LIGHT SIGNALS WITH ENTRANCEAND EXIT GATES AND MEDIAN:ONE OR MORE TRACKS,TWO-WAY VEHICULAR TRAFFIC,TWO LANES EACH WAYWITH MEDIAN.RIGHT ANGLE CROSSING ACUTE ANGLE CROSSINGOBTUSE ANGLE CROSSING12" MAX.IGUX1 - 14'-6"* 15' -- MIN.12' MIN.1____ iV V.-.-.-.-.-.-------------.--- t. TRACK -------------.-.-.-.--i 4'-6"I MIN.4'-6" ~ p:: ~~:jMIN. 1I \7'96' I '(()\714'-6" Ir~ ~MIN.~I12" MAX.4'-6" IMIN. ~N'''ÛÛ'rli~.',,~'N_MIN.' "MAX~'h.12" MAX ' ~'6" I :12--------------.-t-~*15'12' MIN.4'-6" f-J~ \7()4'-6" IMIN. i-MIN.I _14'-6"M 6.oi i iii i-F 14'-6"tMIN.ri i ¡- 6' MIN. MIN. 12,1~'IN. *12"MAX.:)6.LX()~\7 /::4'-6" 1-- h IMIN.12" MAX.~()X- 14'-6"-- MIN.12" MAX.YVVÛÛ15'* 12' MIN. r --4'-6" r -14'-6" r-¡I MIN.I X()~1 MIN. I _6' MIN. -- hi ~ 12" MAX.U I : 6. (14'-6"MIN.6. 6. Ir-r~ ~4'-6"~12" MAX. MIN.* USE OF MINIMUM DIMENSIONS SHALL BE AUTHORIZED BYSCRRA MANAGER OF C&S ENGINEERING OR DESIGNATE.NOTES:1. TYPICAL LOCATION PLAN MAY VARY AS CONDITIONS REQUIRE.2. ALL DIMENSIONS ARE SHOWN IN FEET AND INCHES.3. ADDITIONAL MEDIAN WIDTH MAY BE REQUIRED TO PROVIDECLEARANCE FOR 24" BACKROUNDS, WINDGUARD OR GATECOUNTERWEIGHTS.4. BACKLIGHTS MAY BE ADDED AS CONDITIONS REQUIRE.5. ROADWAY GATE ARM LENGTH SHALL NOT EXCEED 32' MEASUREDFROM THE CENTER OF KINGPIN TO THE TIP OF GATE ARM.6. SEE STANDARD DRAWINGS ES8300 THROUGH ES8308 FORADDITIONAL INFORMATION.7. WHERE BOTH ENTRANCE GATES AND EXIT GATES ARE ALIGNEDON A MEDIAN, FRONT LIGHTS SHALL BE INSTALLED ON THEASSEMBL Y CLOSEST TO TRAFFIC APPROACHING IN THELAWFUL DIRECTION.8. DEVIATION FROM THIS STANDARD SHALL BE APPROVED BYSCRRA MANAGER OF C&S ENGINEERING OR DESIGNATE.REVISIONS I FINAl REVEW BY' C&SDRC I DATr, 11121/081THE SOUTHERN CALIFORNIAENGINEERINGREGIONAL RAIL AUTHORITY iieii METROLINKSTANDARDS 8375Al ,OR IT'S OFFICERS OR AGENTSlAGER, COWlACATIONS At SIGNAlS ENGf£ERtlSHALL NOT BE RESPONSIBLEFOR THE ACCURACY OR(.vl/1~ t( M..~e./ COMPLETENESS OF THISSOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY700 SOUTH FLOWER STREETREV. I DATE I DESCRTIO I DES. I ENG. 1 DIRCTOR, ENGEERIG AN CONSTRUTIO /' PLAN SHEET LOS ANGELES, CALIFORNIA 90017TYPICAL LOCATION PLANNONEFLASHING LIGHT SIGNALS WITH ENTRANCE 1 OF 1AND EXIT GATES AND MEDIANES8375

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!