12.07.2015 Views

Exhibits J, Grade Crossings Standards Manual - Metrolink

Exhibits J, Grade Crossings Standards Manual - Metrolink

Exhibits J, Grade Crossings Standards Manual - Metrolink

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

5’-0" MIN.6"(TYP)(TYP)NOTES:VEHICULAR GATE ARM2’-0" WIDE STOP LINEAT RIGHT ANGLE TOTRAVELED WAY PERCH. 8 CA MUTCDSTEEL TUBE RAIL(TYP) SEE NOTE 4CURB AND GUTTER5’-0"MIN.(TYP)8’-0"15’-0"12’-0" MIN.AS AUTHORIZEDBY SCRRA2’-0" CLR.FROM FACEOF DEVICE1’-0"2’-6" 4’-0"(TYP)C TRACKL(TYP)2’-0"4’-0"CONCRETE CROSSINGPANELS (TYP)10’-0" (TYP)0" CF10’-0"(TYP)1’-6"FULL HT.CURBCURB LINE DETAIL CALTRANS 27BWITH RPM (RAISED PAVEMENT MARKER)TYPE G SUPPLEMENT (TYP)CURB LINE (4" SOLID WHITERETRO REFLECTIVE STRIPE)2’-0"MIN.(TYP)1. THESE STANDARDS ARE NOT INTENDED TO REPLACEEXISTING REGULATORY STANDARDS, NOR TO BE ASUBSTITUTE FOR ENGINEERING KNOWLEDGE,EXPERIENCE AND JUDGMENT, BUT ARE REQUIREMENTS,WHICH ARE MOST IMPORTANT FOR SAFE CONSTRUCTION,MAINTENANCE AND OPERATION OF PEDESTRIAN FACILITIESAT HIGHWAY-RAIL GRADE CROSSINGS. SINCE THE ACTUALDESIGN WILL TYPICALLY BE SITE SPECIFIC, INFORMATIONSHOWN ON THIS DRAWING WILL BE MODIFIED AS NECESSARYIN CLOSE COLLABORATION WITH SCRRA.2. FOLLOW CALIFORNIA MUTCD FOR STRIPING, SIGNING, ANDOTHER TRAFFIC WARNING DEVICES.3. REFER TO THE FOLLOWING FOR ADDITIONAL DESIGNINFORMATION:a. SCRRA ENGINEERING STANDARD ES4201 FOR CONCRETEPANELS AND PAVED END RAMP.b. SCRRA ENGINEERING STANDARD ES5101 FOR INTER-TRACK FENCE.5’-0" MIN.VAR.PCC SIDEWALK4’-6"45(TYP)4’-0"MIN.(TYP)PCCSIDEWALKc. SCRRA ENGINEERING STANDARD ES5107 FOR SECURITYACCESS GATE, K-RAIL AND BOLLARDS.d. SCRRA ENGINEERING STANDARD ES4001 FOR TRACKSECTIONS AND ASPHALT CONCRETE PAVEMENT DETAILS.21’-0" (8’ GATE)18’-0" (5’ GATE)21’-0" (8’ GATE)18’-0" (5’ GATE)AUDIBLE DEVICE2’ WIDE DETECTABLEWARNING STRIP (TYP)STEEL TUBE RAIL (TYP)SEE NOTE 4PEDESTRIAN GATEARM (TYP)SWING GATE(TYP)PEDESTRIAN WARNINGDEVICE (TYP)SIGNAL HOUSESECURITY ACCESS GATEPER ES2915 (TYP)X X X X X X X X X X X X XK-RAIL4’-6"MIN.(TYP)6’-0"MIN.8’-0" MAX.1’-6"TO BE DETERMINED(TYP)IN FIELD12" SOLIDWHITE STRIPEPAVED RAMPAC (TYP)4’-0" (5’ GATE)6’-0" (8’ GATE)2’-6"(TYP)1’-6"(TYP)4’-6"MIN.(TYP)(TYP)1’-6"(TYP)4’-6"MIN.1’-0"(TYP)X X X X X X X X X X X X456"e. SCRRA ENGINEERING STANDARD ES4002 FOR SWINGGATE DETAILS.f. SCRRA ENGINEERING STANDARD ES8308 AND ES8309FOR PEDESTRIAN WARNING DEVICES.g. CALTRANS STANDARD PLANS A20A FOR TRAFFICLINES (STRIPES) AND A88A FOR DETECTABLE WARNINGSURFACE (STRIPE).h. CALTRANS STANDARD PLANS A20B DETAIL 27B ANDA20C TYPE "G" FOR PAVEMENT MARKERS.i. APWA STANDARD PLAN 606-2, TYPE "B" FOR STEELTUBE RAIL. (ONE ADDITIONAL RAIL 4" FROM BOTTOM).4. FENCING AND STEEL TUBE RAIL LOCATIONS SHALL BEADJUSTED AS NECESSARY TO PROVIDE SCRRA MAINTENANCEVEHICLES ACCESS TO RIGHT-OF-WAY AND SIGNAL & TRACKFACILITIES WITH SCRRA APPROVAL.5. PREEMPTION AND TOTAL WARNING TIME SHALL TAKE INTOCONSIDERATION THE PEDESTRIAN WALKING DISTANCE ANDCLEARANCE TIME AND SHALL MEET THE REGULATIONSAND REQUIREMENTS OF THE AMERICAN WITH DISABILITIESACT (ADA) AND CA MUTCD.EXTEND 4’-0" WELDED WIREMESH FENCE AT LEAST 50’-0"BEYOND CROSSING (TYP)XX X XX X9’-6" 15’-0" MIN. 9’-6"BOLLARD (TYP)XLEGENDSTRIPINGDETECTABLE WARNING STRIPTO BE DETERMINEDTO BE DETERMINEDCONCRETEIN FIELDIN FIELDAC PAVEMENT (SHOWN FORPEDESTRIAN FACILITY ONLY)12 12 240DIRECTION OF TRAFFIC1"=12’PRE-FINAL SUBMITTALREV.DATEREVISIONS- - -- -DESCRIPTIONDES.ENG.DRAWN BY: A. CARLOS DATE:12/12/09APPROVED BYMANAGER: CIVIL ENGINEERINGDIRECTOR OF ENGINEERING AND CONSTRUCTIONTHE SOUTHERN CALIFORNIAREGIONAL RAIL AUTHORITYOR ITS OFFICERS OR AGENTSSHALL NOT BE RESPONSIBLEFOR THE ACCURACY ORCOMPLETENESS OF THISPLAN SHEETSOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY700 SOUTH FLOWER STREET, 26TH FLOORLOS ANGELES, CALIFORNIA 90017ENGINEERING STANDARDSPEDESTRIAN FACILITIES AT VEHICLE CROSSINGENTRANCE GATES ONLYSTANDARDSCALE:REVISION SHEETCADD FILE:4011NONE- 1 OF 1ES4011

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!