12.07.2015 Views

Specifications

Specifications

Specifications

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CProduct DimensionsCAABA = Height/DiameterB = Total LengthC =BHex Size on Main ComponentØ 2.000"+.010-.000PANEL MAX. PANEL MIN. PANELOPENING THICKNESS THICKNESSCOUPLING BODIES see drawing .50 .12OR INSERTSTERMINATIONIN-LINEBODIESTERMINATIONIN-LINEINSERTSTUBING/THREAD SIZE TERMINATION TYPE SHUTOFF A B C3/8" OD Flare compression CQGD06100106 1.96 4.211/2" OD Flare compression CQGD06100108 1.96 4.423/4" OD Flare compression CQGD06100112 1.96 4.491/2" Taper Male NPT CQGD06100208 1.96 3.81 1.00TUBING/THREAD SIZE TERMINATION TYPE SHUTOFF A B C3/8" OD Flare compression CQGD06200106 1.62 4.351/2" OD Flare compression CQGD06200108 1.62 4.453/4" OD Flare compression CQGD06200112 1.62 4.633/8" Taper Male NPT CQGD06200206‡ 1.62 3.81 1.001/2" Taper Male NPT CQGD06200208 1.62 3.95 1.003/4" Taper Male NPT CQGD06200212‡ 1.62 4.15 1.00Coupling BodiesCoupling InsertsCQG SERIES & ACCESSORIESAll measurements are in inches (millimeters) unless otherwise noted.Tubing must meet stated inside and outside diameters.Panel Mount AdaptorDESCRIPTIONPanel mount adapter kit (fits both bodies & inserts)PART NO.CQG06PMKIT01The ChemQuik ® Dual Containment System is an easy way to "double contain" critical chemicallines, protecting plant and personnel in case a primary process line ruptures or "sweats". Thesystem provides a protective secondary line to catch any fluid and routes it to a safe location.ChemQuik ® DualContainment Flare NutsThese fittings work with any ChemQuik coupling with fine thread flare terminations or a common flare style fitting. In addition, thepanel mount version can be mounted into a pump cabinet or other panel mount connection point. The primary linecan then be routed from the coupling directly to a pump, connected to a ChemQuik coupling or to afitting at the panel mount fitting.The “weep port" serves to vent the area between the primary and secondary lines so that pressure cannotbuild up in case of a primary line rupture. The leaking fluid can then be routed to acontainment vessel or to a leak detector.FLARE NUTCQDCNUT0408CQDCNUT0612CQDCNUT0812CQDCNUT1216DESCRIPTIONDual containment nut, 1/4" OD process line x1/2" OD secondary containment line.Dual containment nut, 3/8" OD process line x3/4" OD secondary containment line.Dual containment nut, 1/2" OD process line x3/4" OD secondary containment line.Dual containment nut, 3/4" OD process line x1" OD secondary containment line.FLARE FITTINGCQPMDCNUT0408CQPMDCNUT0612CQPMDCNUT0812CQPMDCNUT1216DESCRIPTIONPanel mount dual containment nut, 1/4" OD Processline x 1/2" OD secondary containment line.Panel mount dual containment nut, 3/8" OD Processline x 3/4" OD secondary containment line.Panel mount dual containment nut, 1/2" OD Processline x 3/4" OD secondary containment line.Panel mount dual containment nut, 3/4" OD Processline x 1" OD secondary containment line.| Call toll free 1-800-444-2474 or visit us at www.colder.comCopyright © 2011 by Colder Products Company. All rights reserved. Colder Products Company,Colder Products and CPC are registered trademarks with the US Patent & Trademark Office.97

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!