12.07.2015 Views

Series of all-purpose physical and chemical environmental ... - Zycon

Series of all-purpose physical and chemical environmental ... - Zycon

Series of all-purpose physical and chemical environmental ... - Zycon

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

UtilityInstrumentation (LHU113)Temperature <strong>and</strong> humidity indicator-controller (for LHU-113)ModelOperating modeDisplaySettingProgram memory capacitySetting <strong>and</strong>indicationrangesSetting <strong>and</strong>indicationresolutionIndicationaccuracyInputControlCommunications (Options)Auxiliary functionsES-102Program operation, constant operation7 segment LED displayMechanical key input9 steps per pattern (Repetition: 1to 99 times)Temperature: 25 to +9013 to 194 FHumidity: 0 to 100rhTime: 0 to 99hrs 59min. 100 to 999hrs.Temperature: 0.10.18 FHumidity: 1rhTime: 1minute1hrs. for 100hrs. or moreTemperature: 0.5typ.0.9 FHumidity: 2rhtyp.Time:within 30 seconds per monthThermocouple type T (CopperCopper-Nickel)PID controlE-BUS, GP-IB, RS-232C, RS-485Input burn-out detection functionUpper <strong>and</strong> lower temperature &humidity limit alarm functionSelf-diagnostic function (watchdog timer)Alarm indication functionPower cut protection functionTimer function (automatic start/ stop)Refrigerator capacity automatic control <strong>and</strong> othersPID control temperature(& humidity) controllerThe PID controlled electronic temperature(& humidity) controller provideshighly accurate <strong>and</strong> automatic control <strong>of</strong><strong>all</strong> operations once the desiredtemperature (& humidity) is set.Program operationConstant or program operation can beselected for <strong>all</strong> inst<strong>all</strong>ed instrumentation.Program operation can run up to 9 stepsper pattern, set the timer for auto-start<strong>and</strong> auto-stop, <strong>and</strong> specify ramp settingfor each step. (Except LC) For example,the timer activates when the chamberreaches the set temperature <strong>and</strong> stopsautomatic<strong>all</strong>y when the set time haselapsed. Reliable performance fortesting, drying, sterilizing, <strong>and</strong> othertypes <strong>of</strong> treatments are assured. Alsoequipped with a display to show theremaining time.Upper temperature limitdeviation warningWhen the temperature is set, thewarning function is automatic<strong>all</strong>y set toactivate at 10adjustable*<strong>of</strong> thepreset temperature.*Only LC must be fixed with 10.*Specifications differ according to the models. .For further information, please contact us. ERC200MERC200MCDROMInst<strong>all</strong>ationTest setting & controlMonitoringProgram settingComplete safety featuresIn addition to a ground leakage breakerwhich also protects against overcurrent,some models feature an overheatprotector or thermal fuse as a secondarysafety device providing added protection.OutputWindows RPlatinous K <strong>Series</strong> Compact Ultra Low Laboratory ChamberTemperature ChamberRS232CRS485ConverterBench-top TypeTemperature& HumidityChamberEnvironmental TestingCentralized Control S<strong>of</strong>twareERC-100M/200M/300M(sold separately)The application s<strong>of</strong>tware makes it easyto monitor operation, central control,<strong>and</strong> remote control <strong>of</strong> up to 16 ESPECtest chambers.(monitoring only for 300M)*Applicable for Laboratory Chambers manufactured in 1999or after. (LC is not supported.)Chambers must be equipped with a communication port(optional) which corresponds with each s<strong>of</strong>tware.*S<strong>of</strong>tware: English/ Chinese (in simplified Chinese characters)/Japanese. (English/ Japanese only for 300M)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!