Lightning- and surge protection<strong>EnerPro</strong> <strong>12V</strong> - <strong>60V</strong> -<strong>Tr</strong><strong>EnerPro</strong> DC/AC2-pole surge arrester acc. to EN T2 T3 (C+D); IEC SPD class II + III for low voltagefor protection of low voltage AC and DC power supply lines up to 6 A• High performance surge protective device for low voltage supply voltages of:nominal 12, 24, 36, 48, or 60 V DC 1)• With built in low - pass Filter• Unprotected and protected side strictly separated• Longitudinal and transverse surge voltage protection• High nominal impulse discharge current of 10x 20 kA (8/20 µs)• Operating current up to 6 A DC or AC• Direct mounting on mounting plate, or click on 35mm DIN rail (EN 50022)• Maintenance free execution1) other voltages on requestProduct description:The 2-pole <strong>EnerPro</strong>..V-<strong>Tr</strong> consists of a two stage protective circuit with gas filled arresters used as primaryprotection stage. The fine protection is effected exclusively by a RLC low-pass filter and a high performancesuppressor diode with Fail-safe function.There are no significant leakage currents due to the absence of varistors (MOV).Application:The <strong>EnerPro</strong>..V-<strong>Tr</strong> with low voltages from <strong>12V</strong> to <strong>60V</strong> has been designed for the protection of power supplieswith power consumption up to 6A, for highly sensitive electronic equipments.Due to their wide operating voltage range (from 12 V up to 60 V DC), their high impulse discharge capacity(line-to-ground: 20 kA at wave 8/20 µs) and to their easy installation on either mounting plate or 35mm DINrail, this SPD can be used universally also for AC current supplies.This SPD type serves as a. lightning and surge protection for DC or AC low voltage power supplies up to 6Apower consumption. For installation between the boundary 2-3, according to the LPZ conception of IEC EN62305 part 1-4. (VDE V 0185 Teil 1.-4)Protects People and Valuables


Technical DataApplicationSurge Protective Device for operating currents up to 6A with an impulse discharge current capability of 20 kA (8/20 µs)fulfil requirements acc. to IEC EN 61643 - 11.Type <strong>EnerPro</strong> <strong>12V</strong>-<strong>Tr</strong> 24V-<strong>Tr</strong> 36V-<strong>Tr</strong> 48V-<strong>Tr</strong> <strong>60V</strong>-<strong>Tr</strong>Article and order number 24 12 00 24 24 00 24 36 00 24 48 00 24 60 00Rated voltage (between 1- 2 resp. 1 p - 2 p ) U c [V-DC][V-AC]1282417362448306043Max. operating voltage(between 1- 2 resp. 1 p - 2 p )Umax [V-DC][V-AC]15102720402953378560Max. operating current Imax [A] 6 6 6 5 4Longitudinal DC resistance R [mΩ] ≤ 27Longitudinal inductance L [µH] ≤ 20Protection level line-ground at 1 kV/µs and Isn Urest [V] max. ≤800V………typical (90%) ≤650VProtection level line-line typ. at 1 kV/µs and Isn Urest [V] 20/27 37/55 55/85 85/110 95/1251) Short circuit) current extinction capability(line 1 – line 2) typ.1) Follow-on (short-circuit) current extinctioncapability (line-ground) typ.Nominal impulse discharge current10x at 8/20 µsIk [A-DC] ≤ 6 ≤ 6 ≤ 6 ≤ 1.0 ≤ 1.0Ik [A-DC] ≤ 1 ≤ 1 ≤ 1 ≤ 0.75 ≤ 0.75Isn [kA] 20Service life test current (500x at 10/700 µs) il [A] 200Max imp. discharge current at 10/700 µs Isgr [A] 1000Max. AC-discharge current (50 Hz / 5x 0.5 s) Iwn [A] 50Max. AC-current 50 Hz / 0.5 s Ig [A] 80Operating temperature range t [°C] - 25 ... + 85Wire cross-section [mm 2 ] Cu 2.5 rigid solid or 1.5 flexible stranded with isol. sleeve (for screwterminals)Housing size WxHxD (see drawing) [mm] 17.5x87x58 Polycarbonate-halogen-free / yellow (Polyurethane sealedprotection circuit)1) at higher short circuit currents, the follow-on (short circuit) current must be interrupted by an appropriate fuse (F) for extinguishing.(in alternating current mode the extinguishing capability is significantly higher than the short circuit currents indicated above)Dimensions (mm)Protection circuit Diagram17.528581<strong>EnerPro</strong>...V-<strong>Tr</strong>............1 pequipment2190 8765 87F+(−)−(+)4p221, 2 = unprotected side 1 p , 2 p = protected sidewidth of 17,5mm = 1 DIN - module size (1TE)<strong>EnerPro</strong> <strong>12V</strong>- <strong>60V</strong> -<strong>Tr</strong>08.02.2007) .pdf© copyright 2007 by LEUTRON <strong>GmbH</strong>Subject to technical modifications anddelivery possibilitiesLEUTRON <strong>GmbH</strong>Lightning- and Surge ProtectionHumboldtstrasse 30-32D-70771 Leinfelden-EchterdingenGERMANYTelephone +49 711 / 9 47 71-0Telefax +49 711 / 9 47 71-70Email: info@leutron.dewww.leutron.de

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!