12.07.2015 Views

Excess Flow, Check, Filler & Vapor Equalizing Valves

Excess Flow, Check, Filler & Vapor Equalizing Valves

Excess Flow, Check, Filler & Vapor Equalizing Valves

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

RegO ® <strong>Excess</strong> <strong>Flow</strong>, <strong>Check</strong>, <strong>Filler</strong>, & <strong>Vapor</strong> <strong>Equalizing</strong> <strong>Valves</strong>Swing-Away Back Pressure <strong>Check</strong> <strong>Valves</strong> forContainer or Line ApplicationsUL®Designed to provide protection of a container opening when desired flowis always into the vessel. May also be used in the line applications whereflow must be limited to one direction.When used with the appropriate single check filler valve, the combinationforms a double check filler valve suitable for use in filling of bulk storagetanks.The swing-away check offers more efficient flow rates than conventionaldesigns. It swivels open vertically to reduce pressure drop across thevalve and improves flow rates.Part Number Inlet Connection Outlet Connection Wrench Effective Length Propane Liquid Capacity at Various Differential Pressures (GPM)Brass Steel F. NPTM. NPT Hex Flats (Approx.) 5 PSIG 10 PSIG 25 PSIG 50 PSIG6586D A6586D 2” 2” 2 7 ⁄8” 2 7 ⁄16” 190 270 420 600NOTE: Multiply flow rate by .94 to determine liquid butane capacity.Back Pressure <strong>Check</strong> <strong>Valves</strong> for FlangedInstallationDesigned to provide high flow capacity and allow more efficient tank fillingthan conventional designs. The unobstructed throat area reduces flowturbulence through the valve, thereby reducing pressure drop. Large flowchannels and spacious side ports assure ample capacity for the mostdemanding high capacity filling operations.The valve is designed for installation in internally threaded flanges in containerbottoms.Part NumberFlange ConnectionM. NPTWrench HexFlatsOverall LengthThreaded EndTo PortUL®Propane Liquid Capacity at Various Differential Pressures(GPM)5 PSIG 10 PSIG 25 PSIG 50 PSIGA3400L4 2”5¼” 1 5 ⁄16” 223 316 500 707SlottedA3400L6 3” 5 9 ⁄32” 1 9 ⁄16” 424 600 949 1342<strong>Excess</strong> <strong>Flow</strong>,<strong>Check</strong>, <strong>Filler</strong> & <strong>Vapor</strong><strong>Equalizing</strong> <strong>Valves</strong>NOTE: For installation in flange tank connections with internal threads, see the “Flanged Installation in Container” section under “<strong>Excess</strong> <strong>Flow</strong> <strong>Valves</strong>.”Multiply flow rate by .94 to determine liquid butane capacity and by .90 for liquid anhydrous ammonia capacity.Sight <strong>Flow</strong> Indicators for Bulk PlantsDesigned to promote maximum pump efficiency, these indicators enable bulk plant operatorsto visually inspect liquid flow conditions. With glass on both sides of the indicator, flowcan be observed from either side, even under some poor light conditions. The integral swingcheck also serves as a back-check valve to prevent reverse flow and product loss if the hosefails in a loading operation.By installing an indicator on the upstream side of the plant pump, suction conditions can beobserved and the pump speed adjusted to obtain the maximum possible flow rate withoutcavitation. Additionally, if an indicator is installed in the piping at the loading rack, just aheadof the loading hose, the operator can maintain a constant check on pump conditions.Both installations are designed to allow for observation to provide maximum pump efficiencyand assure safe plant pump operation.In compressor operations a sight flow indicator installed in the liquid line will give a visualindication when the tank car or transport is emptied. Compressor operation can then beimmediately reversed to start recovery of the vapor.PartNumberInlet/OutletConnectionsLengthA7794 2" F. NPT 5 3 ⁄4"A7796 3" F. NPT 7 3 ⁄8"NOTE: For fixed pipe installations only83

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!