We close this section saying that the gravimetric calibration <strong>of</strong> the signal axis usingchemically identical polymers can avoid the issues discussed in Section 4 on the uncertaintiesarising from ablation, ionization, and detection. However, the issues arising fromuncertainties in repeatable sample preparation, and data analysis, still affect the gravimetriccalibration techniques. In sample preparation, the problem <strong>of</strong> phase separation as a function<strong>of</strong> molecular mass (each component <strong>of</strong> the blend is usually <strong>of</strong> a different molecular mass)appears. In solution, the solubility <strong>of</strong> some polymers is very molecular-mass dependent (e.g.,polyethylene glycol solubility in tetrahydr<strong>of</strong>uran). As the solvent evaporates in the drieddroplet technique the oligomers <strong>of</strong> different molecular masses come out <strong>of</strong> solution atdifferent rates and thus may find themselves at different matrix:polymer ratios. In dataanalysis the issues <strong>of</strong> determining the baseline consistently and drawing areas consistently isstill an issue and may incorrectly represent the amount <strong>of</strong> mass in one or the other polymer inthe blend. Further, if one polymer is a small fraction <strong>of</strong> the other, the experimental noise willcause major problems with peak integration.7. Experimental Method for the Calibration <strong>of</strong> the Signal AxisWe wish to look at the calibration <strong>of</strong> the signal axis using the expression derived insection 6. Calibration <strong>of</strong> the signal axis has been done before, specifically by Shimada, et al.10, 11 by fractionating the polymer into distinct oligomers with supercritical fluidchromatography (SFC) and then using these materials to calibrate the spectrometer and obtainthe MMD <strong>of</strong> the whole polymer from these calibrations. Our method does not depend on theSFC fractionation but rather uses narrow MMD polymers without fractionation with differentend groups so they can easily be distinguished in the mass spectrum.7.1 Samples and ReagentsThree octyl-initiated (M n <strong>of</strong> 6200 u, 9180 u, and 12 600 u (as measured by thevendor using SEC with multiple-angle laser light scattering) and one butyl-initiated (M n<strong>of</strong> 9100 u) polystyrene samples were synthesized by Scientific Polymer Products, Inc.(Ontario, NY). These four polymers will be referred to as OctylB, OctylA, OctylC, andButylA, respectively. SRM 2888, a PS <strong>of</strong> about 6800 u made by Polymer Source(Dorval, Québec, Canada) was used as received. Two other PS with butyl end groups21

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!