<strong>Megaflo</strong> <strong>HE</strong>Unvented hot water cylinders


Feel invigoratedNothing quite matches the warm welcome offered toyou by the outstanding range of <strong>Megaflo</strong> <strong>HE</strong> unventedwater heating systems from <strong>Heatrae</strong> <strong>Sadia</strong>.How do we guarantee our customers’ needs – the best possibleperformance, quality and reliability – when developing unventedwater heating systems? How do we ensure our system providesfaster-filling baths and powerful mains-pressure showers withmaximum reliability and efficiency?The answer is simple. We use only the most advanced unventedwater heating technology available. And, where this doesn’t meetthe standards of performance, efficiency and reliability we insistupon, we develop innovative new technologies of our own tobridge the gap.These advances can come in many forms. Sophisticated Duplexstainless steel cylinder construction for maximum strength andcorrosion resistance; CFC/HCFC-free injected foam, encasing theentire system including the bosses and valves, for the bestpossible heat insulation; a floating baffle system to replace aconventional external expansion vessel – for quicker and simplerinstallation. And to prove our confidence in this advanced newtechnology, we provide every new system with a 25-yeartransferable cylinder guarantee with on-site service support.Then we detail precisely what sets the <strong>Megaflo</strong> <strong>HE</strong> apart fromeverything else…• Constructed in Duplex stainless steel formaximum strength – pressure tested to 15 bar.• Patented internal floating baffle system toaccommodate water expansion.• No anode – eliminates costly anodemaintenance.• Insulated casing for the temperature andpressure relief valve to minimise heat loss.• Unique ‘L-shaped’ long-life Superloy immersionheater reaches deeper into the tank giving morehot water.• Patented cold water inlet diffuser minimisesmixing of cold and hot water.• High performance ‘coil-in-coil’ heat exchanger.• Exceeds CHeSS* Best Practice for recovery timesand insulation.• Improved insulation for maximum heat retention.• New water inlet controls increase flow rates by upto 35%.• Improved performance at low pressures down to1 bar.• Installer friendly design.* Energy Efficiency Partnership: Central Heating System Specifications.3


<strong>Megaflo</strong> <strong>HE</strong>Innovative technologyCylinder constructionDuplex stainless steel offers a superior resistance to corrosion especially inaggressive water areas, compared with some grades of stainless steel, glass-linedsteel and copper. Because Duplex is a low carbon, high chromium content alloy, itresists all forms of corrosion including pitting, crevice corrosion, uniform corrosionand stress corrosion cracking, without the use of a sacrificial anode. In addition, thetungsten inert gas welding coupled with the special post weld processes ensuresthe same level of corrosion resistance and mechanical strength as the parent metal.This ensures the longest possible working life for every cylinder.The combination of its lightweight and very strong construction makes <strong>Megaflo</strong> <strong>HE</strong>easier to handle on site. Every unit is pressure tested in the factory to 15 bar – fivetimes the normal operating pressure – making <strong>Megaflo</strong> <strong>HE</strong> suitable for all domesticand commercial applications.No sacrificial anode is required with <strong>Megaflo</strong> <strong>HE</strong>. With inferior grades of stainlesssteel, glass-lined steel and copper, sacrificial anodes are required to achieve adegree of corrosion resistance. However they require regular replacement which,if not carried out can result in premature cylinder failure. <strong>Megaflo</strong> <strong>HE</strong> overcomes anyneed for this by using top quality Duplex stainless steel.Specification comparison to a copper unit with air gapTypical maximum working pressureTypical operating pressureMaterial<strong>Megaflo</strong>10.0 bar3.0 barDuplex stainless steelCopper4.5 bar2.1 barCopper4


Internal air gapThe internal air gap and floating baffle system allowsfor a compact self contained unit which eliminatesthe need for an external expansion vessel and allowsfor a quicker and simplified installation.<strong>Megaflo</strong> <strong>HE</strong> meets the BBA internal expansion volumeendurance test with no reduction in operating pressureor flow rates.Floating baffleExpanded water is accommodated within thecylinder using an internal air gap maintained by apatented floating baffle. This baffle floats on thesurface of the water within the cylinder to maintainthe integrity of the air gap.Before expansionAfter expansion5


Baxi <strong>Megaflo</strong> System <strong>HE</strong> boilerThe <strong>Heatrae</strong> <strong>Sadia</strong> <strong>Megaflo</strong> <strong>HE</strong> cylinder is an idealcompanion for the Baxi <strong>Megaflo</strong> System <strong>HE</strong> boiler.• 15, 18, 24, 28 and 32kW options available.• SEDBUK band ‘A’ rated.• 2 years parts and labour warranty.7


<strong>Megaflo</strong> <strong>HE</strong> SystemFitThe ultimate unvented cylinder.<strong>Megaflo</strong> <strong>HE</strong> is also available in apopular pre-plumbed format –designed to significantly reduceon-site installation time.These factory assembled units are pre-plumbed and pre-wired with230V central heating controls, pump, two 2-port motorised valves,automatic by-pass and balancing valve, Primary system filling loop,Primary system pressure gauge and Primary system expansionvessel and auto air vent.This time-saving <strong>Megaflo</strong> <strong>HE</strong> SystemFit package not only speedsinstallation but significantly enhances the quality and integrity ofthe central heating system thus eliminating costly call backs.8


• Simplified on-site installation.• Up to 70% quicker to install.• Factory assembled for reliability – reduces costly call-backsand delays.• Consistent electrical and plumbing layout.• <strong>Megaflo</strong> <strong>HE</strong> – the UK’s No.1 unvented cylinder.Baxi Solo <strong>HE</strong> boilerThe <strong>Heatrae</strong> <strong>Sadia</strong> <strong>Megaflo</strong> <strong>HE</strong> SystemFit cylinderis an ideal companion for the Baxi Solo <strong>HE</strong> boiler.• 15, 18, 24, 28 and 32kW options available.• SEDBUK band ‘A’ rated.• 2 years parts and labour warranty.• 125, 145, 170, 210, 250 and 300 litre capacities – S-plan.• Programmable thermostat with timed Domestic Hot <strong>Water</strong>(DHW) Control.• Separate central heating and hot water zones.• No maintenance three speed circulating pump.• Automatic bypass valve for system efficiency.• Load balancing valve for indirect coil efficiency.• Connections for vented and unvented heating primaries.• Primary system filling loop, Primary system pressure gaugeand Primary system expansion vessel and auto air vent.• ISO 9001:2000 quality assured.• 25-year cylinder guarantee.9


System benefitsEnd userSpecifierdeveloperInstallerEnd userSpecifierdeveloperInstallerHigher flow rates for efficient hot waterdelivery■Meets BBA Internal Expansion VolumeEndurance Test■High performance showering – throughoutthe homeFast-filling bathsQuieter mains pressure system (no noisycistern in the loft)Balanced water pressure – no surprisesPatented cold water inlet diffuser minimisesmixing of cold and hot waterExceeds CHeSS* Best Practice for heatrecoveryFast recovery rates (eg. 15 minutes forCL125 unit)CFC/HCFC free (ODP zero) insulation andinsulated T&P relief valve for maximumheat retentionNo fear of frozen loft pipes**No anode to check or replaceMains fed hygienic hot waterAppliance quality, easy-clean finishLong-life Duplex stainless steel interior25-year transferable cylinder guarantee■■■■■■■■■■■■■■■■■■■■■■No external expansion vesselComplete with mains water isolating valveFlexibility in cylinder siting**Dry roof space increases design options †Cost effective installer friendlyconnectionsNo reduction in operating pressure orflow ratesSupplied with safety and hot watercontrols, wiring centre for indirect modelsand drain valveNo cold feed cistern to install for the hotwater supplyNeater and quicker installationEasy to commissionNo costly shower pump to installLightweight, installer friendly designStronger construction for durability andhigh pressure performanceAll units fully factory tested to ensurereliability■■■■■■■■■■■■■■■■■■■■■Patented internal expansion system■■■Fully indemnified design service ††■■■* Energy Efficiency Partnership: Central Heating System Specifications. ** Assumes sealed system boiler with <strong>Megaflo</strong> <strong>HE</strong> in frost free position. † Assumes no loft conversion. †† Conditions apply.SitingThe <strong>Megaflo</strong> <strong>HE</strong> cylinder is suitable for sitinganywhere in the property. The area of sitingneeds to be frost free and allow access to thesafety discharge.SealedsystemboilerKeyFlowReturnHotColdCentral HeatingSystemDomestic <strong>Water</strong>SystemCold mains in10


Performance<strong>Megaflo</strong> <strong>HE</strong>’s pressure and flow rateperformance will exceed those available fromcomparable vented systems, thermal storeunits, multi-point instantaneous gas heatersor combination boilers. It offers flexibility incylinder siting as it can be positioned in anyconvenient location that allows a suitablerouting of the discharge pipe from its safetyvalve. It should not be installed in areas thatare subject to freezing.<strong>Megaflo</strong> <strong>HE</strong> unvented water systems deliverhot water at flow rates up to 72 litres per minand offer one of the most rapid heat-up andrecovery rates available, making it ideallysuited to a wide variety of applications.Available in seven capacities, ranging from70 to 300 litres, in both direct and indirectsystems, there is a model to suit everyenvironment.<strong>Megaflo</strong> <strong>HE</strong> cylinder performanceNominal capacity(litres)70125145170210250300Model CL(indirect)Recovery(mins)10151715.5192327Model D(direct 3kW)Heat up(mins)87137153181199238287Model DD(direct 6kW)Heat up(mins)n/a697791100119144Model DDD(direct 9kW)Heat up(mins)n/an/an/an/a677996<strong>Megaflo</strong> <strong>HE</strong> cold water combination valveFlow in v Flow out for various static inlet pressuresModel DD& DDDBoost heattop element(mins)n/a667279859297Heat lossin 24 hoursCL are indirect models with one electrical element. CL210<strong>HE</strong>, CL250<strong>HE</strong> and CL300<strong>HE</strong> have additionalboost upper element boss blanked off, additional immersion heater available.(kWh)1.101.491.651.771.972.092.258070Outlet flow from cold watercombination valve (I/min)60504030201000 10 20 30 40 50 60 70 80 90Inlet flow to cold water combination valve (I/min)1 bar static 2 bar static 3 bar static 4 bar static 6 bar staticRecovery times for CL models with various boilers outputs(based on 70% recovery)Time to recover throughout 45ºC8070605040302010CL300<strong>HE</strong>CL250<strong>HE</strong>CL210<strong>HE</strong>CL170<strong>HE</strong>CL145<strong>HE</strong>CL125<strong>HE</strong>CL70<strong>HE</strong>08.83010.253511.74013.24514.75016.15517.66019.16520.570227523.48024.98526.490kWByu 000sBoiler output available11


Applications and installationWhich unit to chooseInstaller friendly designApplicationBedsit1 bed 1 bath & shower2 bed 1 bath & shower3 bed 1 bath & shower4 bed 1 bath & shower4/5 bed 2 bath & shower4/5 bed 3 bath & showerLight commercial usesOther commercial usesIndirectCL70<strong>HE</strong>CL125<strong>HE</strong>CL125<strong>HE</strong>CL145<strong>HE</strong>CL170<strong>HE</strong>CL210<strong>HE</strong>CL250<strong>HE</strong>CL250<strong>HE</strong>CL300<strong>HE</strong>DirectD70<strong>HE</strong>DD125<strong>HE</strong> / DD145<strong>HE</strong>DD145<strong>HE</strong> / DD170<strong>HE</strong>DD210<strong>HE</strong>DD210<strong>HE</strong>DD250<strong>HE</strong>DD300<strong>HE</strong>DDD250 / DDD300<strong>HE</strong>DDD250 / DDD300<strong>HE</strong><strong>Megaflo</strong> <strong>HE</strong> has been designed to facilitate a trouble-free installation.Compact and rounded in design, with all connections accessible atthe front of the unit. <strong>Megaflo</strong> <strong>HE</strong>’s lightweight construction means it’seasy to handle and convenient to site almost anywhere in the home.• Integral cylinder wiring centre for controls.• Strong feet for additional stability.• Wiring centre for indirect controls supplied loose with everyindirect <strong>Megaflo</strong> <strong>HE</strong> (factory fitted to SystemFit models).Figures are for guidance only and are based on BS 6700 recommendations.D = One elementDD = Two elementsDDD * = Three elementsCL = Indirect with one element suppliedNote: <strong>Heatrae</strong> <strong>Sadia</strong>’s Specification Advice Team should be contacted todiscuss requirements and designs for specific sites.High usage applicationsWhen it comes to meeting the needs of demanding applications,e.g. rugby club shower rooms, two or more <strong>Megaflo</strong> <strong>HE</strong> unitscan be installed in parallel. Detailed specifications and designs,including comprehensive plumbing information, are available bycontacting our Specification Advice Team on tel: 01603 420220,by fax: 01603 420229, or by email: specifier@heatraesadia.comExample parallel installationsApplicationNursing home (27 beds)Student accommodation(18 showers)Sports club (13 showers)Rugby club(max. 80 showers per hour)House (5 bed & 5 bath)Bar with food servery(300 persons)Hotel (8 bed & 6 bath)Guest house(4 bath & 3 shower)Indirect2x CL300<strong>HE</strong>6x CL210<strong>HE</strong>(2x 3)2x CL250<strong>HE</strong>3x CL300<strong>HE</strong>2x CL300<strong>HE</strong>3x CL145<strong>HE</strong>Direct3x DDD250<strong>HE</strong>6x DDD300<strong>HE</strong>(2x 3)• All plumbing connections are colour coded and accessible atthe front of the cylinder.• Lightweight construction.• Drain valve supplied loose with every <strong>Megaflo</strong> <strong>HE</strong>(factory fitted to SystemFit models).• <strong>Megaflo</strong> <strong>HE</strong> base moulding with integral hand grips.• Detachable lifting handle.Typical installation of a <strong>Megaflo</strong> <strong>HE</strong> indirect cylinderTo hot outletsElement /ControlshousingPrimaryreturnPrimaryflowInstaller trainingT&PreliefvalveInletBalancedcold waterconnection(if required)TundishDrain cockCold watercombinationvalveMains watersupplyExpansionvalve core unitSecondaryreturn tapping(if required)DischargepipeApproved courses are available nationwide for operative training.For further details of such courses, call 0845 600 7402.Hot outletDischarge pipemust terminateat a visible,safe placeCold inletIllustration showing two <strong>Megaflo</strong> <strong>HE</strong> units in parallel for high usageapplications. Photograph for illustrative purposes only – bespoke pipeworkrequired for specific applications.* DDD cylinders are supplied with three elements and a blanking plug which can be fittedas required to 4 bosses, one at the boost position and three near the base of the unit.This gives a choice of heating options dependent on application. CL210<strong>HE</strong>, CL250<strong>HE</strong>and CL300<strong>HE</strong> have boost upper element boss blanked off.12


Key components<strong>Megaflo</strong> <strong>HE</strong>3Construction1 Internal air gap to accommodateexpanded water.2 Patented floating baffle maintains theair gap.3 22mm compression / 3 ⁄4" BSP hot wateroutlet.4 Cylinder manufactured from top gradeDuplex stainless steel – specially selectedfor its high strength and resistance tostress and crevice corrosion.5 22mm compression / 3 ⁄4" BSP cold waterinlet.6 Integral feet.7 22mm compression / 3 ⁄4" BSP primary flow.8 22mm compression / 3 ⁄4" BSP primaryreturn.9 Primary heating coil for use with indirectsystems (CL models only).12 Grommets on indirect pipework forprofessional finish.High performance13 Totally insulated with 100% CFC-free (ODPzero) Polyurethane to minimise heat loss(50mm thick).14 Long-life 3kW Superloy 825 immersionheater.Safety controls15 1 ⁄2" Temperature and Pressure Relief Valvewith innovative insulation casing, operatingat 90ºC/10 bar.16 Indirect thermal controls (CL models).17 Drain valve.18 Wiring centre for indirect controls(indirect <strong>Megaflo</strong> <strong>HE</strong> only).2413149618127161551110 Patented cold water diffuser.11 White plastic-coated corrosion proofedouter case with grey moulded top andbottom covers and electrical housings forneat and attractive finish.1017 18<strong>Megaflo</strong> <strong>HE</strong> SystemFitIn addition to the components listed above for <strong>Megaflo</strong> <strong>HE</strong>, our SystemFitmodels also include the following features.29Separate Central Heating & Hot<strong>Water</strong> Configuration19 Motorised valve to radiator circuit –22mm on 125L/145L models / 28mmon other models.20 22mm motorised valve to <strong>Megaflo</strong> <strong>HE</strong>coil heat exchanger.21 Wiring centre.22 Programmable thermostat and roomsensor with timed Domestic Hot <strong>Water</strong>(DHW) Control.23 Hot water temperature thermostat.High performance configuration24 Automatic by-pass valve.25 3 speed circulator pump with qualityisolating valves.26 Balancing valve.27 22mm cold water combination valve(supplied loose).28 Combined expansion valve / checkvalve housing.29 22mm or 3 ⁄4" BSP hot outlet to taps.30 22mm Primary flow to <strong>Megaflo</strong><strong>HE</strong>coil heat exchanger.31 22mm Primary return from <strong>Megaflo</strong> <strong>HE</strong>coil heat exchanger.32 Drain cocks.33 Immersion heater with integralthermostat and thermal cut-out.Safety controls34 Temperature and pressure relief valve(with innovative insulation casingsupplied loose) operating at 90ºC /10 bar.35 Tundish.36 High limit hot water thermal cut-out.Connections37 Primary flow connection from boiler –22mm on 125L / 145L models and 28mmon other models.38 Discharge pipe connection 22mm.39 Cold water inlet connection 22mm.40 Primary flow to radiators (CH circuit).41 28mm connection for 2nd CH zone(supplied capped) 170 litre andabove only.42 15mm connection for secondary return(supplied capped).43 Auto air vent.44 Primary system pressure gauge.45 Primary system filling loop.46 Primary system expansion vessel.47 Primary circuit return connection.372545444326242320333631 3047 32 213222 27 4639283435413819404213


Full specificationsCylinder SpecificationNominal capacities 70, 125, 145, 170, 210, 250 and300 litre.Rating<strong>Megaflo</strong> <strong>HE</strong> – Immersion heater/s 3kW @ 240V.Up to four can be fitted dependent on model.<strong>Megaflo</strong> <strong>HE</strong> SystemFit – Immersion heater/s 3kW@ 240V.Outer casing White plastic coated corrosion proofedsteel.Thermal insulation CFC/HCFC-free (ODP zero)flame-retardant expanded polyurethane (50mm thick).GWP 3.1 (Global Warming Potential).<strong>Water</strong> container Duplex stainless steel with internalair-gap system.Pressure testing To 15 bar.Heat unit Long-life Superloy 825 alloy sheathedelement(s), incorporated into an easily removableheater plate, should replacement be necessary.Rated 3.0kW @ 240V.Primary coil 22mm diameter stainless steel.Thermostat <strong>HE</strong> Direct models: Element thermostatadjustable from 10°C to 70°C. Indirect models:Factory-fitted cylinder thermostat adjustable to 70°C.Thermostat SystemFit Element thermostatadjustable from 10°C to 70°C. Factory-fitted cylinderthermostat adjustable to 70°C.Factory fitted safety features Direct models:Manually re-settable cut-out on heating elementoperates at 85°C. Indirect models: High limit thermalcut-out operates at 85°C. Wired in series with twoportmotorised valve (supplied) to provide primaryover temperature protection. All models: Temperatureand pressure relief valve, factory set to operate at0 bar and 90°C (insulation casing supplied loose).Wiring centre for indirect controls (supplied loose).Anode Not required.Approvals BBA and CE approved. Manufactured inthe UK in a BS EN ISO 9001:2000 registered factory.SystemFit Component SpecificationDanfoss TP9000 Programmable RoomThermostat with DomesticHot <strong>Water</strong> (DHW) ControlBuilt in hot water time controlRemote room temperature sensorChrono-proportional control on/offFrost protection settingEasy to use overridesUp to 6 time/temperature changes per day7 day, 5/2 or 24 hour operationWallplate constructionRoom temperature control range 5°C to 30ºC.Holiday modeProgrammer dimensions Width 135mm, Height88mm, Depth 32mm.Sensor dimensions Width 61mm, Height 45mm,Depth 22mm. Designed to meet BS EN60730-2-7and EN60730-2-9.Maximum ambient temperature 45ºC.Timing accuracy ±1 minute.Switch rating 230Vac, 50/60Hz, 3(1)A.Switching action 2x SPDT, type 1BS.Power supply 230Vas, 50H. Memory back upretained for life of product.Honeywell two-port valve:For the central heating and domestic hot water.Model no V4043H.Voltage rating 230V ac 50Hz.Power consumption 6W.Primary water temperature range 5°C to 88ºC.Max ambient temperature 50ºC.Automatic by-pass valve:Model no RWC Diff 391 901.Working pressure 10 bar.Setting range 0.1 to 0.5 bar differential pressure.Maximum primary water temperature 120°C.Pump:Model no Grundfos UPS15-60.Working pressure 10 bar max.Voltage rating 230V ac 50Hz.Starting capacitor 2µF.Power consumption Speed setting I 40W,Speed setting II 65W, Speed setting III 95W.Enclosure protection IP42.InstallationMust be installed by a competent installer inaccordance with Local Regulations. England andWales – Building Regulations G3. Scotland – TechnicalStandards P3. N. Ireland – Building Regulations P5.Fixing Floor mounting.Plumbing Inlet/outlet: 3 ⁄4" BSP male parallel and22mm compression fittings supplied. Indirect coil:3 ⁄4" BSP male parallel and 22mm compression fittingssupplied. 1 ⁄2" T&P Relief Valve: 15mm compressionoutlet supplied.Cold water control 22mm HiFlo cold water valveassembly comprising 3 bar pressure reducer, 1 ⁄4 turnisolating ball valve, line strainer, non-return valve andexpansion valve (8 bar).Cold water control valve (3 bar) is supplied for usewith mains pressure of 16 bar to 1.5 bar, at the lowerpressure, performance will be reduced accordingly.Normal working pressure is 3 bar.Expansion core unit Comprising 8 bar expansionvalve and check valve factory fitted (SystemFit only).<strong>Water</strong> expansion Via air gap built into the top of thecylinder. The patented floating baffle maintains theair gap.SystemFit NOTE: A separate expansion vessel willbe required for sealed primary systems.Flow rates Up to 72 litres per minute (dependingon adequate supply conditions).Minimum water supply requirements 20 litres perminute flow and 1.5 bar pressure. (At lesser values,the unit will operate but outlet flow rates may beunacceptable, especially with multiple draw-offs).Please contact our Specification Advice Team todiscuss specific site conditions if the above minimumrequirement cannot be met.Secondary circulation <strong>HE</strong> Via 22 x 15 x 22mm swepttee (not supplied, available as accessory 95:970:509).Fitted to inlet pipework (circulating pump notsupplied).Secondary circulation is not recommended for directelectric units being used on off-peak electricity tariffs.Secondary circulation SystemFit Via 15mm teepiece on inlet pipe (supplied capped). A WRAS listedbronze circulating pump (not supplied) will berequired.Compatible boilers Gas, electric or oil fired - sealedsystem or open vent type, fitted with integral controlthermostat and thermal cut-out.Tundish <strong>HE</strong> 15mm inlet and 22mm compressionoutlet.Tundish SystemFit 15mm inlet and 22mmcompression outlet factory fitted.Electrical Connection is direct to terminals in theimmersion heater which must be permanentlyconnected to the supply through a double-polelinked isolating switch with a minimum breakingcapacity of 13A.On indirect models, controls should be wired to theboiler, programmer etc. in accordance with thecontrol scheme being used. All electrical installationsmust conform to the latest IEE Wiring Regulations.GuaranteeThe <strong>Megaflo</strong> <strong>HE</strong> Duplex stainless steel vessel carriesa full 25-year transferable on-site service supportguarantee against faulty manufacture or materialsprovided that:• It has been correctly installed as per theinstructions contained in the instruction manualand all relevant Codes of Practice and Regulationsin force at the time of installation.• It has been installed in the UK.• It has not been modified in any way, other thanby <strong>Heatrae</strong> <strong>Sadia</strong> Heating.• The damage is not due to scaling or frost.• It has only been used for the storage of potablewater.• It has not been tampered with or been subjectedto misuse or neglect.• Within 60 days of installation the user completesand returns the certificate supplied along withthe proof of purchase to register the product.Evidence of purchase and date of supply must besubmitted. The unit is not guaranteed againstdamage due to frost. The guarantee is transferable.This guarantee does not affect your statutory rights.The <strong>Megaflo</strong> <strong>HE</strong> cold water control valve isguaranteed for a period of five years from date ofpurchase. The immersion heater and thermal controlsare guaranteed for a period of two years from thedate of purchase.The <strong>Megaflo</strong> <strong>HE</strong> SystemFit components, immersionheater and thermal controls are guaranteed for aperiod of 2 years from the date of purchase. 5 yearsfor cold water control valve and SystemFit Primaryexpansion vessel.14


Dimensions and ordering<strong>Megaflo</strong> <strong>HE</strong> dimensions<strong>Megaflo</strong> <strong>HE</strong> ordering guide<strong>Megaflo</strong> <strong>HE</strong>Indirect<strong>Megaflo</strong> <strong>HE</strong>DirectAAEBBDDCC45.0°5225.0°4930.0°45.0°30.0°45.0°81.081.0ModelD70<strong>HE</strong>CL70<strong>HE</strong>DD125<strong>HE</strong>CL125<strong>HE</strong>DD145<strong>HE</strong>CL145<strong>HE</strong>DD170<strong>HE</strong>CL170<strong>HE</strong>DD210<strong>HE</strong>DDD210<strong>HE</strong>CL210<strong>HE</strong>DD250<strong>HE</strong>DDD250<strong>HE</strong>CL250<strong>HE</strong>DD300<strong>HE</strong>DDD300<strong>HE</strong>CL300<strong>HE</strong>Nominalcapacity(litres)7070125125145145170170210210210250250250300300300Elementrating@240V(kW)1x 31x 32x 31x 32x 31x 32x 31x 32x 33x 31x 32x 33x 31x 32x 33x 31x 3Coilrating(kW)n/a15.4n/a18.3n/a24.3n/a24.3n/an/a24.3n/an/a23.9n/an/a24.5Weightempty full(kg) (kg)23 12325 12525 17427 17631 20035 20434 22839 23338 24839 24943 25345 29546 29650 30055 35556 35660 360Productcode95:050:36095:050:36195:050:36295:050:36395:050:36495:050:36595:050:36695:050:36795:050:36895:050:38095:050:36995:050:37095:050:37195:050:37295:050:37395:050:37495:050:375<strong>Megaflo</strong> <strong>HE</strong> accessory ordering guide<strong>Megaflo</strong> <strong>HE</strong>SystemFitB<strong>Megaflo</strong> <strong>HE</strong> immersion heater with thermostat – upper ‘straight’Swept tee (22x15x22)Productcode95:970:51095:970:509374.7 280.2A282.7<strong>Megaflo</strong> <strong>HE</strong> SystemFit ordering guide1082<strong>Megaflo</strong> <strong>HE</strong>ModelD70CL70DD125CL125DD125CL145DD170CL170DD210 & DDD210CL210DD250 & DDD250CL250DD300 & DDD300CL300249418A784784108910891215121513721372147314731725172520402040DCB552552552552552552552552552552552552552552C49449479379389489410191019109510951322132215731573D308354308354308354308354308354308354308354388.0En/a315n/a315n/a315n/a315n/a315n/a315n/a315ModelCL125SCL145SCL170S28CL210S28CL250S28CL300S28Nominalcapacity(litres)125145170210250300Elementrating@240V(kW)1x 31x 31x 31x 31x 31x 3Coilrating(kW)18.318.724.324.323.924.5Optional boost element available for CL210 to CL300 units.For an extra element, order code number 95:970:510Productcode95:050:38295:050:38495:050:39395:050:39495:050:39595:050:396<strong>Megaflo</strong> <strong>HE</strong> SystemFitModelCL125SCL145SCL170S28CL210S28CL250S28CL300S28A111512411398149917512065B552552552552552552C8969971122119814251676D5426437688441071132215


ContactSpecificationT: 01603 420220 F: 01603 420229E: specifier@heatraesadia.comAfter <strong>Sales</strong> ServiceT: 08701 600125 F: 08701 600181E: heatraesadiaservice@heateam.co.ukWeb www.heatraesadia.com<strong>Brochure</strong>s for all of our products are availablefree of charge. Please call our literature hotlineon 01603 420127.Domestic Heating and Hot <strong>Water</strong>• Aerheat• Amptec• Electromax• Electromax Solar• <strong>Megaflo</strong> <strong>HE</strong>• Megalife <strong>HE</strong>• Showers• SolarNational service networkCommercial Hot <strong>Water</strong><strong>Heatrae</strong> <strong>Sadia</strong> products are inherently reliableand are designed to meet the demanding needsof all users.A nationwide network of experienced engineersis available to provide fast and efficient on-siteservice support.In addition, spare parts for the complete rangeof products are readily available through a widevariety of stockists.• B3M / C3M• FBM• Handy Dri and Hair Drier• Immersion Heaters• StreamlineDrinking <strong>Water</strong>• Supreme• Express• Handy• Hotflo• Multipoint• UTC• SuperChill<strong>Heatrae</strong> <strong>Sadia</strong> Heating Hurricane Way Norwich Norfolk NR6 6EA<strong>Heatrae</strong> <strong>Sadia</strong> Heating may introduce modifications to their productsfrom time to time. Consequently, the details given in this brochureare subject to alteration without notice.Baxi boilersContact 0844 871 1525 for literature and further information.95 900 807 Issue <strong>HE</strong>13 © <strong>Heatrae</strong> <strong>Sadia</strong> Heating. 2009.This product is printed on 50% post consumer recycledpaper. That is paper that has been previously used eg.newspapers and magazines. This product is printedusing vegetable based inks which are non toxic. Pleaserecycle this product once you have finished with it.