12.07.2015 Views

Model: PWFY-P36NMU-E-AU - Mitsubishi Electric Sales Canada Inc.

Model: PWFY-P36NMU-E-AU - Mitsubishi Electric Sales Canada Inc.

Model: PWFY-P36NMU-E-AU - Mitsubishi Electric Sales Canada Inc.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Model</strong>: <strong>PWFY</strong>-<strong>P36NMU</strong>-E-<strong>AU</strong> – DIMENSIONS600300(23-5/8) (11-13/16)Control boxService panel2X2-ø14(9/16) Hole450(17-23/32)500(19-11/16)(Mounting pitch)525(20-11/16)Top view35(1-13/32)46(1-13/16)134(5-9/32)Front view Right side viewø27(1-3/32) Knockout hole• Y-type strainer (RC3/4) ················ 1pc.• Heat Insulation material ·············· 1pc.• Connector set ······························ 2set• Washer ········································ 2pcs.• Expansion joint(P72) ··················· 2pcs.[From RC3/4 to RC1]Water outlet(RC3/4 FPT)P72:Use the Expansion joint of accessoriesPiping space(right side)400(15-3/4)ø27(1-3/32) Knockout holeTop viewø27(1-3/32) Knockout holeConnection pipe of outdoor unit(Gas)P36:ø15.88(5/8) P72:ø19.05(3/4) ø27(1-3/32) Knockout holeService space(front side)Fig. AConnection pipe of outdoor unit(Liquid)ø9.52(3/8) Water inlet(R3/4 FPT)Drain (R1 FPT)480(18-29/32)80 140 60(3-5/32) (5-17/32) (2-3/8)(3-15/16)91(3-19/32)91(3-19/32)114(4-1/2)206(8-1/8)(4-1/32)(6-1/2)(7-17/32)(2-5/32)10216519154100(1-13/32)(2-3/16)3555Note 1. Seal around connection openings to prevent moisture from enteringthe unit.2. Ensure adequate service space is right around the unit, according to Fig A.3. Please always make water circulate or add the brine to the circulation waterwhen the ambient temperature becomes 0degC(32°F )or less.4. The unit is not designed for outside installations.5. Install the unit in an environment where the wet bulb Temp.will not exceed 32degC(90°F).6. Please always make water circulate or pull out the circulationwater completely when not using it.7. The water circuit must use the closed circuit.8. Please don't use the steel material for the water piping material.9. Connect the strainer which is put as accessory to water inlet pipe.10. Unit must be isolated from potable water system.800(31-1/2)(Mounting pitch)205(8-3/32)300(11-13/16)<strong>Mitsubishi</strong> <strong>Electric</strong> Air Conditioning & Refrigeration Systems Works acquired ISO9001 certification under Series 9000 of the International Standard Organization (ISO)based on a review of quality warranties for the production of refrigeration and airconditioning equipment.Certificate Number FM33568ISO Authorization SystemThe ISO 9000 series is a plant authorization system relating to quality warranties asstipulated by the ISO. ISO 9001 certifies quality warranties based on the "design,development, production, installation and auxiliary services" for products built atan authorized plant.<strong>Mitsubishi</strong> <strong>Electric</strong> Air Conditioning & Refrigeration Systems Works acquired environmentalmanagement system standard ISO 14001 certification.<strong>Mitsubishi</strong> <strong>Electric</strong> <strong>Sales</strong> <strong>Canada</strong> <strong>Inc</strong>.www.<strong>Mitsubishi</strong><strong>Electric</strong>.caThe ISO 14000 series is a set of standards applying to environmental protection set by theInternational Standard Organization (ISO).Certificate Number EC97J1227Specifications are subject to change without notice.SB_<strong>PWFY</strong>-<strong>P36NMU</strong>-E-<strong>AU</strong>_201007

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!