12.07.2015 Views

Jabcore Classic Hardcore Replacement - Jablite

Jabcore Classic Hardcore Replacement - Jablite

Jabcore Classic Hardcore Replacement - Jablite

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

U-VALUE: 0.15W/m²KP/A RATIO JABCORE JABCORECLASSIC 70 CLASSIC 1001.00 250 2000.90 250 2000.80 250 2000.70 200 2000.60 200 2000.50 200 1750.40 175 1750.30 175 1500.25 150 1500.20 150 1500.15 100 100U-VALUE: 0.10W/m²KP/A RATIO JABCORE JABCORECLASSIC 70 CLASSIC 1001.00 350 3500.90 350 3500.80 350 3000.70 350 3000.60 350 3000.50 350 3000.40 300 2750.30 275 2750.25 275 2500.20 250 2500.15 250 200Keystandard thicknesstwo layers of standard thicknessthree layers of standard thicknessStandard thicknesses: 75, 100, 150mmInstallationDamp-proof membrane<strong>Jabcore</strong> <strong>Classic</strong> should not be regarded as a damp-proof membrane. A suitable DPM must be provided,positioned either above or below the <strong>Jabcore</strong> <strong>Classic</strong>, or above the concrete slab.Site preparationThe use of <strong>Jabcore</strong> <strong>Classic</strong> in this application means that no hardcore is required. The excavated sub-baseshould be blinded with 50mm compacted reject sand, to receive either the <strong>Jabcore</strong> <strong>Classic</strong> or the DPM.<strong>Jabcore</strong><strong>Jabcore</strong> <strong>Classic</strong> is placed on the blinded surface or the DPM, either in a single or double layer, with closely-buttedjoints. If a double layer is used, then through-joints must be avoided. If the concrete slab is to be poured directlyonto the <strong>Jabcore</strong> <strong>Classic</strong>, the joints should be covered with 75mm-wide adhesive tape to prevent cold bridging asdetailed in BRE Report 262.Vertical upstands of <strong>Jabcore</strong> <strong>Classic</strong> should be used around the perimeter to prevent cold bridging.ReinforcementA type A98 steel-mesh reinforcement to BS 4483 (or other suitable reinforcement) should be incorporated inthe concrete slab. If reinforcement spacing-blocks are used, they should spread the reinforcement and workingloads sufficiently to prevent penetration of, or damage to, the <strong>Jabcore</strong> <strong>Classic</strong> or the DPM.Concrete slabThe concrete slab is laid to the required thickness and either tamped or powerfloated to provide the requiredfinish. During these operations, the surface of the <strong>Jabcore</strong> <strong>Classic</strong> or the DPM should be protected from impactdamage or excessive trafficking by the use of spreader boards.Floors | Walls | Roofs <strong>Jablite</strong> <strong>Jabcore</strong> Technical Information 6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!