44-45-03-16Page 11Specifications, continuedEnvironmental <strong>and</strong> Operating ConditionsParameter Reference Rated Extreme Transport <strong>and</strong> storageAmbientTemperature67 to 77 °F19 to 25 °C58 to 131 °F15 to 55 °C32 to 131 °F0 to 55 °C–40 to 151 °F–40 to 66 °CRelativeHumidity (%RH) 0 to 55* 10 to 90* 5 to 90* 5 to 95*VibrationFrequency (Hz)Acceleration (g)000 to 700.10 to 2000.20 to 2000.5Mechanical ShockAcceleration (g)Duration (ms))Mounting Position fromVerticalTilted ForwardTilted BackwardTilted to Side (± )Power RequirementsVoltage (VRMS)Frequency (Hz)Power ConsumptionGeneral Reference DataStray RejectionStatic Charge EffectsRFI SusceptibilityLine Noise EffectsStylus LifeTechnical Assistance005˚5˚5˚119 to 121238 to 24249.8 to 50.259.8 to 60.224 watts maximum1305˚30˚10˚102 to 132204 to 26449 to 5159 to 615305˚90˚20˚102 to 132204 to 26448 to 5258 to 622030AnyAnyAnyN/AN/AN/AN/ACommon Mode Rejection Ratio: 120dB or 1 LSB (whichever is greater) at 60 Hz with maximumsource impedance of 100 ohms.Normal Mode Rejection Ratio: 60dB with a 100% span peak-to-peak maximum at 60 Hz.Exposed panel surfaces capable of withst<strong>and</strong>ing a discharge from a 250pf capacitor charged to10 KV through 100 ohms.Capable of withst<strong>and</strong>ing an EMI-field generated from a 5-watt transmitter being held at 1 meter,<strong>and</strong> operating at 151.685 <strong>and</strong> 450 MHz.Field terminals for connecting power line to recorder can withst<strong>and</strong> the IEEE Surge Withst<strong>and</strong>ingCapability Test to a level of 2.5KV.Typically capable of printing one chart per day for five years under clean room conditions.Toll-free 800 number puts technical assistance only a phone call away.FDA Compliance The <strong>Honeywell</strong> <strong>Pasteurization</strong> High Temperature Short Time (<strong>HTST</strong>) DR45AH, SafetyThermal Limit Recorder (<strong>STLR</strong>) DR45AS, <strong>and</strong> <strong>Pasteurization</strong> <strong>Flow</strong> DR45APRecorder/Controller comply with the requirements of the dairy industry set forth by the U.S.Department of Health <strong>and</strong> Human Services, Food <strong>and</strong> Drug Administration, Grade APasteurized Milk Ordinance. (1993)* The maximum rating only applies up to 104 °F (40 °C). For higher temperatures, the RH specification is derated to maintain constantmoisture content.Specifications subject to change without notice.WARRANTY/REMEDY<strong>Honeywell</strong> warrants goods of its manufacture as being free of defective materials <strong>and</strong> faulty workmanship. Contact your localsales office for warranty information. If warranted goods are returned to <strong>Honeywell</strong> during the period of coverage, <strong>Honeywell</strong>will repair or replace without charge those items it finds defective. The foregoing is Buyer's sole remedy <strong>and</strong> is in lieu of allother warranties, expressed or implied, including those of merchantability <strong>and</strong> fitness for a particular purpose.Specifications may change without notice. The information we supply is believed to be accurate <strong>and</strong> reliable as of thisprinting. However, we assume no responsibility for its use.While we provide application assistance personally, through our literature <strong>and</strong> the <strong>Honeywell</strong> web site, it is up to the customerto determine the suitability of the product in the application.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!