DR4500A Truline HTST, STLR, and Pasteurization Flow ... - Honeywell
DR4500A Truline HTST, STLR, and Pasteurization Flow ... - Honeywell
DR4500A Truline HTST, STLR, and Pasteurization Flow ... - Honeywell
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
44-45-03-16Page 11Specifications, continuedEnvironmental <strong>and</strong> Operating ConditionsParameter Reference Rated Extreme Transport <strong>and</strong> storageAmbientTemperature67 to 77 °F19 to 25 °C58 to 131 °F15 to 55 °C32 to 131 °F0 to 55 °C–40 to 151 °F–40 to 66 °CRelativeHumidity (%RH) 0 to 55* 10 to 90* 5 to 90* 5 to 95*VibrationFrequency (Hz)Acceleration (g)000 to 700.10 to 2000.20 to 2000.5Mechanical ShockAcceleration (g)Duration (ms))Mounting Position fromVerticalTilted ForwardTilted BackwardTilted to Side (± )Power RequirementsVoltage (VRMS)Frequency (Hz)Power ConsumptionGeneral Reference DataStray RejectionStatic Charge EffectsRFI SusceptibilityLine Noise EffectsStylus LifeTechnical Assistance005˚5˚5˚119 to 121238 to 24249.8 to 50.259.8 to 60.224 watts maximum1305˚30˚10˚102 to 132204 to 26449 to 5159 to 615305˚90˚20˚102 to 132204 to 26448 to 5258 to 622030AnyAnyAnyN/AN/AN/AN/ACommon Mode Rejection Ratio: 120dB or 1 LSB (whichever is greater) at 60 Hz with maximumsource impedance of 100 ohms.Normal Mode Rejection Ratio: 60dB with a 100% span peak-to-peak maximum at 60 Hz.Exposed panel surfaces capable of withst<strong>and</strong>ing a discharge from a 250pf capacitor charged to10 KV through 100 ohms.Capable of withst<strong>and</strong>ing an EMI-field generated from a 5-watt transmitter being held at 1 meter,<strong>and</strong> operating at 151.685 <strong>and</strong> 450 MHz.Field terminals for connecting power line to recorder can withst<strong>and</strong> the IEEE Surge Withst<strong>and</strong>ingCapability Test to a level of 2.5KV.Typically capable of printing one chart per day for five years under clean room conditions.Toll-free 800 number puts technical assistance only a phone call away.FDA Compliance The <strong>Honeywell</strong> <strong>Pasteurization</strong> High Temperature Short Time (<strong>HTST</strong>) DR45AH, SafetyThermal Limit Recorder (<strong>STLR</strong>) DR45AS, <strong>and</strong> <strong>Pasteurization</strong> <strong>Flow</strong> DR45APRecorder/Controller comply with the requirements of the dairy industry set forth by the U.S.Department of Health <strong>and</strong> Human Services, Food <strong>and</strong> Drug Administration, Grade APasteurized Milk Ordinance. (1993)* The maximum rating only applies up to 104 °F (40 °C). For higher temperatures, the RH specification is derated to maintain constantmoisture content.Specifications subject to change without notice.WARRANTY/REMEDY<strong>Honeywell</strong> warrants goods of its manufacture as being free of defective materials <strong>and</strong> faulty workmanship. Contact your localsales office for warranty information. If warranted goods are returned to <strong>Honeywell</strong> during the period of coverage, <strong>Honeywell</strong>will repair or replace without charge those items it finds defective. The foregoing is Buyer's sole remedy <strong>and</strong> is in lieu of allother warranties, expressed or implied, including those of merchantability <strong>and</strong> fitness for a particular purpose.Specifications may change without notice. The information we supply is believed to be accurate <strong>and</strong> reliable as of thisprinting. However, we assume no responsibility for its use.While we provide application assistance personally, through our literature <strong>and</strong> the <strong>Honeywell</strong> web site, it is up to the customerto determine the suitability of the product in the application.