EQUIPGNDL1CH11 21C L11 21OY 2Y1W1CRDUAL CAPACITYSCHEMATI C DIAGRAM (LADDER FORM)TO INDOOR UNITNOTES:1. Compressor furnished with inherent thermal protection.2. Fan motor furnished with inherent thermal protection.3. To be wired in accordance with National Electric Codeand local codes.4. Outdoor unit control requires a minimum of 27 VA,24 VAC control power.5. Use copper conductors only. use conductors suitablefor at least 75°C (167°F).6. If indoor section has a transformer with a groundedsecondary, connect the grounded side to "C".7. If any of the original wire, as supplied, must be replaced,use the same or equivalent wire.8. Check all electrical connections inside control box fortightness.9. Do not attempt to operate unit until service valves havebeen opened (back seated)10.Must use thermostat listed in pre-sale literature.11.Compressor windings shown for 2 cylinder operation.For 1 cylinder operation reverse R and S markings.5STARTCAP1STARTRELAY2RVSD C C PL1 1 2 3 4 5 1 2HP/AC C SEV RVS C HI LO PL2CHCOMPCAPA B C DCHRSLPS1PL3 23HPS1PL4 2OAT 12PL54OCT 5VCBRNVHBLUODFBLKL 2YELCCHREDCOMPCL-t°-t°CLPSHPSOATOCTCHVPSL223OFMFANCAPCCHREDBLUDUAL CAPACITYCONNECTION DIAGRAM L1BLK208 / 230 - 1 - 60L2YELPOWER SUPPLYORN ORNBLKCH13 11EQUIP GND23 21RVSBRNBRNPL1 1 2 3 4 5 1 2HP/AC C SEV RVS C HI LO PL2OY 2Y1W1CRUFORCEDDEFROSTDEFROSTTIME (MIN)PL5COMM STATUS OCTA B C DLPSPL3HPSPL4123121245VCBRNVHBLUODFBLKL 2YELCCHREDYEL/PNKYEL/PNKBLU/PNKYELBLULPSHPSBLU/PNKOAT-t°BLKBLKOCT-t°BRNBRNBLKBRNYELVPSBLKBRNCCH5CLBLKSTARTCAPSTARTRELAYYEL12BRN1121COMPCAPBLUYELFAN CAPBRNTO INDOOR UNIT-LEGEND-COMPONENT ARRANGEMENTFACTORY POWER WIRINGCOMM SYSTEM COMMUNICATIONFIELD POWER WIRINGCOMP COMPRESSORFIELD CONTROL WIRINGHPS HIGH PRESSURE SWITCHFACTORY CONTROL WIRINGCHSTARTCOMPONENT CONNECTIONLPS LOW PRESSURE SWITCHCLRELAYFIELD SPLICEOAT THERMISTOR (OUTDOOR AIR)DUAL CAPACITYJUNCTIONOCT THERMISTOR COILCONTROLCOMPCL CONTACTOR LOW CAPACITY (24 V COIL)OFM OUTDOOR FAN MOTORCAPSTARTFANCCH CRANKCASE HEATERCAPCAPCH CONTACTOR HIGH CAPACITY (24 V COIL)RVS REVERSING VALVE SOLENOIDCAP CAPACITORSTATUS SYSTEM FUNCTION LIGHTDCC DUAL CAPACITY CONTROLVPS VAPOR PRESSURE SWITCHUNIT OPERATION/SEE UNIT INSTALLATION INSTRUCTIONS FOR DETAILS1 MINUTE TIME DELAY - WHEN CHANGING FROM LOW TO HIGH, OR HIGH TO LOW, THERE IS A 1 MINUTE TIME DELAY. NOTE,FUNCTION LIGHT (STATUS)CODE ON UNITDEFINITIONDURING CAPACI TY CHANGE DELAY THE OUTDOOR FAN WILL REMAIN RUNNING.CRANKCASE HEATER - OPERATES DURING OFF CYCLE.CONSTANT FLASH / NO PAUSEONE FLASH W/ PAUSENO DEMAND / STAND BYLOW-CAPACITY OPERATIONDEFROST TIME SELECTION - (SHOWN AS DT ON BOARD) THE DEFROST INTERVAL TIME CAN BE FIELD-SELECTED, DEPENDENTUPON LOCAL/GEOGRAPHIC REQUIREMENTS. IT IS FACTORY SET AT 90 MINUTES AND CAN BE CHANGED TOTWO FLASHES W/ PAUSEHIGH-CAPACITY OPERATIONEITHER 30, 60 OR 120 MINUTES.DEFROST - DEFROST WILL ONLY BE PERFORMED AT OUTDOOR TEMERATURES LESS THAN 50°F. DEFROST WILL INITIATE WHENTHREE FLASHES W/ PAUSEOUTDOOR THERMISTOR FAILURETIME SELECTED HAS ELAPSED AND THE COIL TEMPERATURE IS LESS THAN 30°F.( ±2°) AND WILL TERMINATE ATFOUR FLASHES W/ PAUSEALT 3 & 4ALT 5 & 1ALT 5 & 2ALT 6COIL THERMISTOR FAILURETHERMISTOR OUT OF RANGELOW PRESSURE SWITCH TRIPHIGH PRESSURE SWITCH TRIPCOMPRESSOR VC/VH TRIP80°F. (± 5°). UPON DEFROST TERMINATION THE OUTDOOR FAN WILL DELAY 20 SECONDS BEFORE STARTI NG.FIELD INITIATED FORCED DEFROST - (SHOWN AS FORCED DEFROST ON BOARD) BY PLACING A JUMPER ACROSS THE FORCEDDEFROST TERMINALS FOR 5 SECONDS, OR LONGER, AND THEN REMOVING THE JUMPER, THE UNIT WILL INITIATE ADEFROST CYCLE REGARDLESS OF COIL TEMPERATURE. THE DEFROST CYCLE WILL TERMINATE AT 80°F (± 5°).IF COIL TEMPERATURE IS ABOVE 30°F OR OUTDOOR AMBIENT TEMPERATURE IS ABOVE 50°F, DEFROST MODE WILLCONSTANT LIGHT NO PAUSE / NO FLASHBOARD FAILURETERMINATE AFTER 30 SECONDS OF ACTIVE MODE.327897-101 REV. AOATBLBLUBLURSCHBLUBRNREDOFMREDBLKNOTE #11COMPCBLKYELFig. 3—<strong>Wiring</strong> Diagram–060A022063


Copyright 2002 CARRIER Corp. • 7310 W. Morris St. • Indianapolis, IN 4623138ydb3wManufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Book 1 4 PC 101 Catalog No. 533-80064 Printed in U.S.A. Form 38YDB-3W Pg 4 8-02 Replaces: 38YDB-2WTab 5a 5a

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!