12.07.2015 Views

SOP of Buehler MetaServ 250 Grinder Polisher

SOP of Buehler MetaServ 250 Grinder Polisher

SOP of Buehler MetaServ 250 Grinder Polisher

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Standard Operating ProcedureHealthcare and Energy Materials LaboratoriesTitle:Project: AllOperating Grinding Machine/Auto <strong>Polisher</strong> (<strong>Buehler</strong><strong>MetaServ</strong> <strong>250</strong> Single <strong>Grinder</strong> <strong>Polisher</strong>)Applies to: Laboratory users<strong>SOP</strong> no: EQ5017Edition no: 01Valid from: 18 May 2012Topic: EquipmentContentsPurpose ................................................................................................................................................... 11. Introduction ........................................................................................................................................ 32. Responsibilities ................................................................................................................................... 33. Procedures .......................................................................................................................................... 33.1 Materials ....................................................................................................................................... 33.2 Grinding <strong>of</strong> electrospinning needle............................................................................................... 43.4 Contact Information ...................................................................................................................... 64. Records and archives .......................................................................................................................... 64.1 Manuals ......................................................................................................................................... 65. Definitions and abbreviations ............................................................................................................. 66. References .......................................................................................................................................... 77. Change Log .......................................................................................................................................... 78. Appendices .......................................................................................................................................... 72


Standard Operating ProcedureHealthcare and Energy Materials LaboratoriesTitle:Project: AllOperating Grinding Machine/Auto <strong>Polisher</strong> (<strong>Buehler</strong><strong>MetaServ</strong> <strong>250</strong> Single <strong>Grinder</strong> <strong>Polisher</strong>)Applies to: Laboratory users<strong>SOP</strong> no: EQ5017Edition no: 01Valid from: 18 May 2012Topic: Equipment1. IntroductionThis document serves as a guide for users on the proper usage <strong>of</strong> the <strong>Buehler</strong> <strong>MetaServ</strong> <strong>250</strong>Single <strong>Grinder</strong> <strong>Polisher</strong>. The <strong>MetaServ</strong> <strong>250</strong> is used for both manual grinding and polishing;specifically for grinding <strong>of</strong> needle heads for electrospinning in this laboratory.2. ResponsibilitiesPerson or rolePrincipal InvestigatorLaboratory TechnologistLab users and membersActivitiesReview and approve <strong>SOP</strong>. Ensure lab members and userscomply with <strong>SOP</strong>.Compliance with this <strong>SOP</strong>. Report any problems to PrincipalInvestigator. Provide feedback to Principal Investigator.Compliance with this <strong>SOP</strong>.3. Procedures3.1 MaterialsGrinding paper (Grit P 400)Grinding paper (Grit P 240)Grinding paper (Grit P 600)Grinding and PolishingClothsSilicon Carbide Abrasive Paperdia. 200 mm (100/Pk) ProductCode: 30-5218-400Silicon Carbide Abrasive Paperdia. 200 mm (100/Pk) ProductCode: 30-5218-240Silicon Carbide Abrasive Paperdia. 200 mm (100/Pk) ProductCode: 30-5218-6008” Microcloth (10/Pk) ProductCode: 40-7218<strong>Buehler</strong><strong>Buehler</strong><strong>Buehler</strong><strong>Buehler</strong>3


Standard Operating ProcedureHealthcare and Energy Materials LaboratoriesTitle:Project: AllOperating Grinding Machine/Auto <strong>Polisher</strong> (<strong>Buehler</strong><strong>MetaServ</strong> <strong>250</strong> Single <strong>Grinder</strong> <strong>Polisher</strong>)Applies to: Laboratory users<strong>SOP</strong> no: EQ5017Edition no: 01Valid from: 18 May 2012Topic: Equipment17. Only use Emergency Stop button during emergency.18. Check manual for other details.3.4 Contact InformationMicroactive Scientific (Singapore) Pte LtdBlock 9010 #02-103 Tampines Industrial Park ASingapore 528844Tel: 6786 3386 & 6786 3616Email: microactive@pacific.net.sgWebsite: http://www.microactive.com.sgContact Person: Thomas Ang (Director, Marketing/Business Development)Hp: 9633 47804. Records and archives4.1 ManualsUser manual can be found in E3 05-14A.5. Definitions and abbreviationsAbbreviationFull expression and definitionN/A6


Standard Operating ProcedureHealthcare and Energy Materials LaboratoriesTitle:Project: AllOperating Grinding Machine/Auto <strong>Polisher</strong> (<strong>Buehler</strong><strong>MetaServ</strong> <strong>250</strong> Single <strong>Grinder</strong> <strong>Polisher</strong>)Applies to: Laboratory users<strong>SOP</strong> no: EQ5017Edition no: 01Valid from: 18 May 2012Topic: Equipment6. ReferencesNumber Title Reference or linkN/A7. Change LogEdition No. Replaces Changes since last edition01 N/A New document8. AppendicesNumberN/ATitle7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!