CONTROLSDescription:Application ExamplesPump Controller with Audible and Visual AlarmA waste pump control which displays the pump rate in liters per minute with an audible andvisual alarm output which will warn the operator if the waste flow has stopped. The alarmshould not be able to be silenced and should automatically reset when flow rates have returnedto normal. The display should indicate in the format "xxx.x" (LPM).Application Diagram:<strong>Dart</strong> MD10P, MD3P, or MD3EMotor ControlPageItemValuTach153.0MICRO-DRIVEENTERAudibleAnnunciatorFlow Transducer(73 Pulses per Liter)FluidOutletFluidInletDC MotorPumpPump Specs:19 Shaft Rotations = 2 LitersWiring Diagram:MD10PMD3PorMD3EP1-1P1-2P1-3P1-4P1-5P1-6P1-7P1-8NLA-A+COM+5VS1S2*FUSENOT USEDGND+V}AC Line Input 85-265VAC, 50-60 HzSIGNAL OUTMOTORFLOW TRANSDUCER(Frequency Output)P1-9P1-10P1-11P1-12NOCNCIN1NOT USEDNOT USED240VACAudibleAnnunciator* Size fuse according to unit and application. Seeelectrical specifications for maximums.24