Modbus Protocol for ION 7500, ION 7600 and ION 8000 series

Modbus Protocol for ION 7500, ION 7600 and ION 8000 series

Modbus Protocol for ION 7500, ION 7600 and ION 8000 series

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Meter Firmware Revision <strong>Modbus</strong> Register MapMeter Firmware RevisionAll <strong>ION</strong> meters contain a firmware revision string which denotes the meter type<strong>and</strong> version (e.g. “7300V200” denotes version 200 of the 7300 meter).The firmware revision string is available via <strong>Modbus</strong> at a fixed location in the<strong>Modbus</strong> register map. While the string may vary in length from one revision tothe next, the set of <strong>Modbus</strong> registers used to represent the string spans themaximum possible firmware revision string length. On the meter, the firmwarerevision string appears in <strong>Modbus</strong> Holding registers 41901 to 41912.The <strong>for</strong>mat of the firmware revision string in <strong>Modbus</strong> follows a ‘C’ style stringconvention: a <strong>series</strong> of bytes representing ASCII characters terminated by a ‘null’byte (value 00 Hex). In <strong>Modbus</strong>, each 16-bit holding register contains two ASCIIcharacters.The following table shows how the <strong>Modbus</strong> encoding of the string “7300V200”appears.Table 3: <strong>Modbus</strong> string encodingRegister Value (Hex) ASCII41901 3733 ’7’ ’3’41902 3030 ’0’ ’0’41903 5632 ’V’ ’2’41904 3030 ’0’ ’0’41905 0000 NUL NULThe remainder of the firmware revision string registers (in the above case, 41906 to41912) contains null values (0000 Hex).<strong>ION</strong> External Control RegistersAll <strong>ION</strong> external control registers in the meter can be read <strong>and</strong> written via <strong>Modbus</strong>.This section describes how the registers appear to the <strong>Modbus</strong> protocol. There arethree types of external control registers:External Pulse Control RegistersExternal Boolean Control RegistersExternal Numeric Control RegistersFor a complete <strong>Modbus</strong> external control register map, see the <strong>ION</strong> 7300 Series Meter<strong>Modbus</strong> <strong>Protocol</strong> document (Appendix E) located on the Power Measurement website.Page 14

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!