12.07.2015 Views

Initial Checklist - Bel-Aqua Pool Supply, Inc.

Initial Checklist - Bel-Aqua Pool Supply, Inc.

Initial Checklist - Bel-Aqua Pool Supply, Inc.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Unprotected Mode EntryThe pool is unprotected when in this mode. This mode can be used forvacuuming the pool, backwashing the filter, or when filling out the Run &Record worksheet.VR 1000 Ver X.X<strong>Initial</strong> start OKPress the “OK” button.Is anyone in<strong>Pool</strong> or Spa? Y/NCheck the pool/spa forswimmers; answer “N” thesystem will now start inunprotected mode.Unprotected <strong>Pool</strong>Vacuum = X.XThis is the operating vacuumof the pool/spa. Thisnumber will be used in theRun & Record worksheet.<strong>Initial</strong> Set-upComplete? Y/NAnswer “N”, no settingshave been made atthis point.No SwimmersAllowed <strong>Pool</strong>/SpaNo action necessary.Unprotected ModePress OK to endPressing “OK” will take youout of unprotected mode.The system will stay inunprotected mode for 30minutes. An audible beep willbe heard every 20 seconds.Hayward <strong>Pool</strong>ProductsWhen this screen isdisplayed, press “No”and “Menu” simultaneouslyand hold until the screenchanges to:Unprotected ModeEntry Y/NUnprotected ModeEntry Y/NAnswer “Y”.Press the “OK” button to exitunprotected mode, proceedto “Custom InstallProcedure”. Page 14 servicemanual.Run & Record WorksheetA compilation of vacuum readings for the pool, spa, orpool/spa combo.<strong>Pool</strong> only—recordthe pool operatingvacuum on the Run &Record worksheet.Now is the best time to returnyour valves to the lowest vacuumreading configuration. This willbe required in “Custom Install”when the following question isasked.Reset 1 st StabOccurred? Y/NProceed to“Custom Install Procedure”Refer to page 17,of the service manual.Put the Stratum into“Unprotected Mode”,allow the pump to gain a full prime.Unprotected <strong>Pool</strong>Vacuum = X.XSpa only—record thespa operatingvacuum on theRun & Recordworksheet.After recording theoperating vacuums ofthe pool and spa, pressthe “OK” button to exitthe “Unprotected Mode”.<strong>Pool</strong>/Spa combo—placeyour valves into thepool configuration andrecord the operatingvacuum on the R&Rworksheet.Turn your valves to thespa configuration andrecord the operatingvacuum on the R&Rworksheet.Note: The Stratum doesnot have to be shutdown while you changeyour valves.Using the #’s off the Run & Recordworksheet, the highest recordedvacuum will be used when setting the“Hi Vac” for the Stratum. 5” Hgwill be added to the larger numberand rounded down to the nearestwhole number.Ex: 14.2 = 19Ex: 14.8 = 195

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!