25.0'NEWS NEWSNEWS NEWSTEL.19 4T.S.8.0'867.6'3.3'79.0'GTEPIONEER BLVD.DIRECTION OF TRAFFIC5' GRADETRANSITION~40' TO ETWALONDRA BLVD.BUS STOP #41: PIONEER & ALONDRA (NB/FS)SCALE: 1" = 10'SHELTER POSTANCHOR BOLTS & BASE PLATECONC. SIDEWALKLEVEL ACROSSALL POSTSDRY PACK UNDERPLATE 1-1/2" MIN, 2" MAXCONC. FTG(4) #5 E.W.1'-9"3'-6" SQUARE144" CONC. SURROUND TO COL. &BASE PLATE1/2" EXPANSION JOINT ALLAROUND COLUMNKALEIDOSCOPE SHELTER FOOTING DETAILNTS4"3" CLR1'-3" 7 3/4"MIN CLRNOTE:CONCRETE:f'c=3000PSIREINF STL: GRADE 60MIN SOIL BEARING CAP: 1000 PSFREMOVE & DISPOSE OF EXISTING CLEAR CHANNEL BUSSHELTER, BENCH AND/OR TRASH RECEPTACLE AS APPLIESRELOCATE/REINSTALL EXISTING TRASH RECEPTACLE6 REMOVE EXISTING, REPLACE & INSTALL NEW 12' I-STOPPOLE IN EXISTING FOOTING7 REMOVE EXISTING & INSTALL NEW 4" PCC SIDEWALK PERCITY OF NORWALK STD. PLAN 1048 REMOVE EXISTING & INSTALL NEW PCC CURB & GUTTER(MATCH EXISTING) PER CITY OF NORWALK STD. PLAN 105WITH A 12" THICK GUTTER9 INSTALL NEW TOLAR SHELTER, SOLAR LIGHTING, ANDPRESIDIO BENCH PER DETAIL ON SHEET A-4 & SPECIFICATIONSCITY OF NORWALKBUS SHELTER REPLACEMENT PROJECTSHEET:A-13