ITS <strong>6006</strong>Radiated <strong>Immunity</strong> <strong>Test</strong> <strong>System</strong> 6 GHzITS <strong>6006</strong>The ITS <strong>6006</strong> consist of an integrated RF signal generator, RF switch and EUT monitoring interfaces.The unit is designed for various radiated EMC applications in the 80 MHz to 6 GHz frequency range. Inaddition to the generator, the system includes the AM and PM modulators necessary for EMC testing.Other modulators can be connected to the external modulation input of the ITS <strong>6006</strong>. The RF signalcan be switched to one of four outputs, where up to four power amplifiers can be connected directly.Additional RF switches are available for combining two amplifier paths into a single antenna connection.Two of these relays are included for the four amplifier paths.ITS <strong>6006</strong> interlock outputs ensure the activation of the power amplifier for only the selected signal path.The 3.5“color display shows the generator parameters. LEDs indicate the state of further functions.Integrated signal generator 80 MHzto 6 GHzIntegrated RF switch networkMultiple EUT monitoring options3.5“ TFT color displaySafety interlock functionRemote control via USB, RS232 orLANThe EUT monitoring is provided by six digital, one analog and one optical input, as well as four digitaloutputs. Up to three power meters PMR <strong>6006</strong> can be connected directly to the ITS <strong>6006</strong>. The ITS <strong>6006</strong>provides remote control through its network, RS232 and USB interfaces.3 power meterinputs forPMR <strong>6006</strong>Indicators for RF-switchnetwork and interlockfunctions3.5“ color displayEUT monitoring portsand user port for 4 TTLinputs, 4 TTL outputsand supply voltagesRemote control viaRS232, LAN or USBInputs for trigger,external modulation,10 MHz ref outInterlockRF-switch network with2x SPDT relays4 generator outputs82-254005 E02 March 2011


2ITS <strong>6006</strong>Radiated <strong>Immunity</strong> <strong>Test</strong> <strong>System</strong> 6 GHzITS <strong>6006</strong> Block diagram10 MHzExternalTriggerUser-Port-IN 0-3referencemodulationDigital 1 & 2Optical inputAnalog inputUser-Port-OUT 0-3Signal generatorEUT monitoring interfaceControl unit4 RF outputs RF switch 4x Interlock2x SPDT3x PMR <strong>6006</strong>power meterRemote control:LAN, RS232, USBTechnical specificationsGeneratorRFFrequency range:80 MHz – 6 GHzResolution:1 HzReference frequency: 10 MHzMax. adjustment deviation: ±50 HzAging:5 ppmLevel range:-60 dBm to +10 dBm (-60 dBm to +8 dBm at f>3 GHz & ϑ>30°C)Resolution:0.1 dBAccuracy:


ITS <strong>6006</strong>Radiated <strong>Immunity</strong> <strong>Test</strong> <strong>System</strong> 6 GHz3Generator (continued)Pulse modulationModulation frequency range: 1 Hz – 2 kHzFrequency resolution: 1 HzDuty cycle: 10% to 90%External modulationLevel:1 Vpp to get 100% AM, 1 Hz – 10 kHzAnalog portsFront panelMonitoring input analog:User port:PIN 15:PIN 14:PIN 13:PIN 5 and 10:BNC socket, 0-24 V Ri=15 kΩ, 6 mV resolutionD-Sub 15 pole+12 V / max. 200 mA-12 V / max. 200 mA+5 V / max. 200 mAGNDBack panelGenerator outputs:4x N sockets 50 Ω, 80 MHz – 6 GHzInterlock outputs:4x BNC socketsExternal modulation input: BNC socket, impedance >10 kΩ10 MHz reference output: BNC socket, approx. 0 dBm / 50 ΩRF Switch network:Relay type 2x SPDT, N sockets 50 ΩPower up to 100 MHz: 1500 WPower up to 400 MHz: 800 WPower up to 1 GHz: 500 WPower up to 3 GHz: 300 WPower up to 6 GHz: 200 WDigital portsFront panelPower meter inputs 1 to 3: for connecting up to 3 Teseq PMR <strong>6006</strong>Monitoring digital input 1 and 2: BNC socket, 0-24 V via optical coupler Ri=1.5 kΩ, switching thresholdapprox. 2-3 V82-254005 E02 March 2011


4ITS <strong>6006</strong>Radiated <strong>Immunity</strong> <strong>Test</strong> <strong>System</strong> 6 GHzDigital ports (continued)Monitoring optical input: POF (Polymeric optical fiber), HP versatile link HFBR0501 series 40kBd, (avoid scattered light on the front panel)User port:D-Sub 15 pole, 4 TTL inputs, 4 TTL outputsITS <strong>6006</strong> with 2 amplifiers in a rackBack panelTrigger input:Remote portsRS232:USB device connector:Network:BNC socket, TTL for external triggering, max. frequency 100 Hz,trigger delay


RADIATED IMMUNITY TEST SYSTEM 80 MHz - 6 GHzPower Meter Generator Interlock Switch11 A1RF on22 B33 A244 BAmp inAmp inAmp inRADIATED IMMUNITY TEST SYSTEM 80 MHz - 6 GHzPower Meter Generator Interlock Switch11 A1RF on22 B33 A244 BAmp inAmp inAmp inAmp inDigital 10..24 VDigital 10..24 VMonitoringDigital 2 Analog0..24 V 0..24 VMonitoringDigital 2 Analog0..24 V 0..24 VOpticalOpticalUser PortUser PortPowerAmp outAmp outAmp outPowerAmp outAmp outAmp outAmp out6ITS <strong>6006</strong>Radiated <strong>Immunity</strong> <strong>Test</strong> <strong>System</strong> 6 GHzApplication with 3 power amplifiers and 2 antennasITS <strong>6006</strong>SoftwareEUT monitoring: analog, digital, optical to ITS <strong>6006</strong>ITS <strong>6006</strong>EUT monitoringGenerator out 1 to 42x Switch 1/2PM channel 1 to 3EUTDIRECTIONAL COUPLERPowerMeterPowerMeterB1DIRECTIONAL COUPLERAEUTPowerMeterSwitch (part of ITS <strong>6006</strong>)Power amplifier 1 to 3DIRECTIONAL COUPLERApplication with 4 power amplifiers and 2 antennasITS <strong>6006</strong>SoftwareEUT monitoring: analog, digital, optical to ITS <strong>6006</strong>ITS <strong>6006</strong>EUT monitoringGenerator out 1 to 42x Switch 1/2PM channel 1 to 3EUTPowerMeterB 1APowerMeterDIRECTIONAL COUPLEREUTDIRECTIONAL COUPLERPowerMeterB 2DIRECTIONAL COUPLERAPower amplifier 1 to 4Switch (part of ITS <strong>6006</strong>)ITS <strong>6006</strong> datasheet


RADIATED IMMUNITY TEST SYSTEM 80 MHz - 6 GHzPower Meter Generator Interlock Switch11 A1RF on22 B33 A244 BAmp inAmp inRADIATED IMMUNITY TEST SYSTEM 80 MHz - 6 GHzPower Meter Generator Interlock Switch11 A1RF on22 B33 A244 BAmp inAmp inAmp inDigital 10..24 VDigital 10..24 VMonitoringDigital 2 Analog0..24 V 0..24 VMonitoringDigital 2 Analog0..24 V 0..24 VOpticalOpticalUser PortUser PortPowerAmp outAmp outPowerAmp outAmp outAmp outITS <strong>6006</strong>Radiated <strong>Immunity</strong> <strong>Test</strong> <strong>System</strong> 6 GHz7Application with up to 3 GHz with 2 power amplifiers, GTEM cell and connection to the emissions measuring systemITS <strong>6006</strong>SoftwareITS <strong>6006</strong>Generator out 1 to 4EUT monitoring2x Switch 1/2EUT monitoring: analog, digital, optical to ITS <strong>6006</strong>PM channel 1 to 3Power meterPMR <strong>6006</strong>PowerMeterSwitch (part of ITS <strong>6006</strong>)DIRECTIONAL COUPLERPowerMeterB 1A2DIRECTIONAL COUPLERABPower amplifier 1 and 2to emissionmeasuring systemGTEM cellApplication with 3 power amplifiers and GTEM cellITS <strong>6006</strong>SoftwareITS <strong>6006</strong>Generator out 1 to 4EUT monitoring2x Switch 1/2EUT monitoring: analog, digital, optical to ITS <strong>6006</strong>PM channel 1 to 3PowerMeterPowerMeterDIRECTIONAL COUPLERB1DIRECTIONAL COUPLERASwitch (part of ITS <strong>6006</strong>)GTEM cellPowerMeterA 2Power amplifier 1 to 3DIRECTIONAL COUPLERB82-254005 E02 March 2011


8ITS <strong>6006</strong>Radiated <strong>Immunity</strong> <strong>Test</strong> <strong>System</strong> 6 GHzModel range and optionsPart numberDescriptionPower meter PM <strong>6006</strong>, available asPMR <strong>6006</strong> or PMU <strong>6006</strong>RF-Switch network SW 6012USO 4013-RS232-20, USB to serial/opticalconverter254005 ITS <strong>6006</strong><strong>Immunity</strong> test system ITS <strong>6006</strong>, 80 MHz to 6 GHz RF generator,RF switch network, EUT monitoring system, country version EU, UK,US/JP97-254005 ITS <strong>6006</strong>-TCTraceable calibration (ISO17025), order only with the device98-254005 ITS <strong>6006</strong>-DKDDKD calibration (ISO17025), order only with the device254725 PMR <strong>6006</strong>Power meter PM <strong>6006</strong>, 1 MHz to 6 GHz, version R for directconnection to ITS <strong>6006</strong>, cable LE 243-2 included (length 2 m)254746 PMR <strong>6006</strong>-10Power meter PM <strong>6006</strong>, 1 MHz to 6 GHz, version R for directconnection to ITS <strong>6006</strong>, cable LE 243-10 included (length 10 m)254726 PMU <strong>6006</strong>Power meter PM <strong>6006</strong>, 1 MHz to 6 GHz, version USB fordirect connection to PC, cable LE 244 (length 2 m) and storage caseincluded97-254725 PM <strong>6006</strong>-TCTraceable calibration (ISO17025), order only with the device98-254725 PM <strong>6006</strong>-DKDDKD calibration (ISO17025), order only with the device253892 SW 6012Option for ITS <strong>6006</strong>: RF-Switch network 2x SPDT254747 USO 4013-RS232-20Converter USB-to-serial/optical, 20 m POF, optical-to-RS232254700 IOB 4000Input/output box, battery operated EUT monitoring system withoptical interface, incl. USO 4013, 10 m fiber optical cable and storagecase included253715 WIN 6000<strong>Test</strong> house software with 15 months supportFor power amplifiers, directional couplers and antennas see www.teseq.com.WIN 6000, <strong>Test</strong> house software forusing NSG 4070 and ITS <strong>6006</strong>Teseq GmbHLandsberger Str. 255 · 12623 Berlin · GermanyT + 49 30 56 59 88 35 F + 49 30 56 59 88 34desales@teseq.com www.teseq.comITS <strong>6006</strong> datasheet