M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.3035 Page 4/5<br />

Probe <strong>for</strong>ms and<br />

pockets to<br />

Data Sheet<br />

60.9710<br />

V-Note<br />

At present there is<br />

no restrictive statement<br />

from the health<br />

authorities concerning<br />

any danger to<br />

health over short<br />

periods and at low<br />

concentrations, e.g.<br />

after fracture of the<br />

measuring system.<br />

12.99/00376440<br />

Models <strong>ATH</strong>s-<strong>SW</strong>-..<br />

U up to +150°C probe temperature<br />

Screw-in pocket with fixing screw <strong>for</strong> securing on case spigot. Male thread ½" pipe with sealing<br />

shoulder, DIN 3852/2-A, normally brass.<br />

UZ * above +150°C probe temperature<br />

with extension so that the maximum permitted ambient temperature +80°C at case is not<br />

exceeded. Male thread ½" pipe, with sealing shoulder, DIN 3852/2-A, 27 mm a/f, steel.<br />

Models <strong>ATH</strong>f-<strong>SW</strong>-..<br />

U Screw-in pocket with fixing screw (clip <strong>for</strong> clamping the probe). Male thread ½" pipe with sealing<br />

shoulder, DIN 3852/2-A, 27 mm a/f, normally brass.<br />

* above +150°C<br />

Male thread ½" pipe with sealing shoulder, DIN 3852/2-A, 27 mm a/f, steel.<br />

* Pockets U, UZ: <strong>for</strong> compressive-load applications above +300°C, material on enquiry !<br />

Physical and toxicological properties of the expansion media which may escape in the event of a system fracture!<br />

Ranges with<br />

end of scale<br />

°C<br />

below +200°C<br />

+200 to +350°C<br />

+350 to +500°C<br />

Connection diagrams<br />

( 1 )<br />

( 2 )<br />

( 4 )<br />

Dangerous<br />

reactions<br />

—<br />

—<br />

—<br />

Fire/explosion hazard Water<br />

Ignition<br />

temperature<br />

°C<br />

+280<br />

+490<br />

—<br />

Explosion<br />

limit<br />

% v/v<br />

1.2 - 7.5<br />

1.0 - 3.5<br />

—<br />

Code 2, 20 with changeover contact Code 7, 70 with n.c. (break) contact and<br />

lock-out<br />

( 4 ) ( 2 ) ( 1 )<br />

Code 27, 270<br />

System I with changeover contact<br />

System II with n.c. (break) contact and<br />

lock-out<br />

( 4 ) ( 2 ) ( 1 ) ( 1 ) ( 4 ) ( 2 )<br />

( 1 )<br />

( 2 )<br />

Code 27, 270<br />

System I with changeover contact<br />

System II with changeover contact and<br />

lock-out<br />

( 1 )<br />

( 2 )<br />

( 1 )<br />

( 2 )<br />

( 4 )<br />

( 4 ) ( 2 ) ( 1 )<br />

Code 22, 220, 2020<br />

System I and II with changeover contact<br />

contamination<br />

K<br />

X<br />

X<br />

—<br />

Toxicological data<br />

irritant danger to<br />

health<br />

X<br />

X<br />

—<br />

X<br />

X<br />

—<br />

toxic<br />

—<br />

—<br />

—<br />

( 1 ) ( 4 ) ( 2 )<br />

Code 7, 70 with changeover contact and<br />

lock-out<br />

( 1 )<br />

( 4 ) ( 2 )<br />

( 1 )<br />

( 4 ) ( 2 )<br />

STB / STB<br />

Code 7070<br />

with changeover contact and<br />

lock-out<br />

( 2 )<br />

( 1 )<br />

STB / STB<br />

Code 7070<br />

with n.c. (break) contact and<br />

lock-out<br />

( 1<br />

( 2