12.07.2015 Views

Beta Analytic Radiocarbon Dating Laboratory

Beta Analytic Radiocarbon Dating Laboratory

Beta Analytic Radiocarbon Dating Laboratory

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CALIBRATION OF RADIOCARBON AGE TO CALENDAR YEARS(Variables: C 13/C 12=-9.9:lab. mult=l)<strong>Laboratory</strong> number: <strong>Beta</strong>-259068 /"


BETA ANALYTIC INC.DR. M.A. TAMERS and MR. D.G. HOOD4985 S.W. 74 COURTMIAMI, FLORIDA, USA 33155PH: 305-667-5167 FAX:305-663-0964beta@radiocarbon.comREPORT OF RADIOCARBON DATING ANALYSESMs. Justine McKnightReport Date: 5/26/2009Archaeobotanical ConsultingMaterial Received: 4/28/2009Sample DataMeasured<strong>Radiocarbon</strong> Age13C/12CRatioConventional<strong>Radiocarbon</strong> Age(*)<strong>Beta</strong>-259068 140+/-40BP -9.9_o4ao 390+/-40BPSAMPLE: 18CV171FS616ANALYSIS : AMS-Standard deliveryMATERIAL/PRETREATMENT : (charred material): acid/alkali/acid2 SIGMA CALIBRATION : Cal AE> 1440 to,1540 (Cal BP 510 to 420) AND Cal AD 1540 to 1630 (Cal BP 400 to 320)<strong>Beta</strong>-259069 600+/-40 BP -25.9 o/ooSAMPLE: 18FR18Feal7ANALYSIS : AMS-Standard deliveryMATERIAL/PRETREATMENT : (charred material): acid/alkali/acid2 SIGMA CALIBRATION : Cal AD 1290 to 1420 (Cal BP 660 to 530)590 +/- 40 BP<strong>Beta</strong> - 259070 650 +/- 50 BP -27.3 o/ooSAMPLE: 18ST2HEARTHANALYSIS : Radiometric-Standard deliveryMATERIAL/PRETREATMENT : (charred material): acid/alkali/acid2 SIGMA CALIBRATION : Cal AD 1280 to 1420 (Cal BP 670 to 530)620 +/- 50 BP<strong>Beta</strong>-259071 120+/-40BP -9.9 o/ooSAMPLE: 18ST570FS380ANALYSIS : AMS-Standard deliveryMATERIAL/PRETREATMENT : (charred material): acid/alkali/acid2 SIGMA CALIBRATION : Cal AD 1440 to 1640 (Cal BP 510 to 310)370 +/- 40 BPDates are reported as RCYBP (radiocarbon years before present,"present" = AD 1950). By international convention, the modernreference standard was 95% the 14C activity of the National Instituteof Standards and Technology (NIST) Oxalic Acid (SRM 4990C) andcalculated using the Libby 14C half-life (5568 years). Quoted errorsrepresent 1 relative standard deviation statistics (68% probability)counting errors based on the combined measurements of the sample,background, and modern reference standards. Measured 13C/12Cratios (delta 13C) were calculated relative to the PDB-1 standard.The Conventional <strong>Radiocarbon</strong> Age represents the Measured<strong>Radiocarbon</strong> Age corrected for isotopic fractionation, calculatedusing the delta 13C. On rare occasion where the Conventional<strong>Radiocarbon</strong> Age was calculated using an assumed delta 13C,the ratio and the Conventional <strong>Radiocarbon</strong> Age will be followed by "*".The Conventional <strong>Radiocarbon</strong> Age is not calendar calibrated.When available, the Calendar Calibrated result is calculatedfrom the Conventional <strong>Radiocarbon</strong> Age and is listed as the"Two Sigma Calibrated Result" for each sample.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!