12.07.2015 Views

JUMO AQUIS 500 CR

JUMO AQUIS 500 CR

JUMO AQUIS 500 CR

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>JUMO</strong> GmbH & Co. KGDelivery address:Mackenrodtstraße 14,36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607e-mail: mail@jumo.netInternet: www.jumo.net<strong>JUMO</strong> Instrument Co. Ltd.<strong>JUMO</strong> HouseTemple Bank, RiverwayHarlow, Essex CM 20 2TT, UKPhone: +44 1279 635533Fax: +44 1279 635262e-mail: sales@jumo.co.ukInternet: www.jumo.co.uk<strong>JUMO</strong> Process Control, Inc.8 Technology BoulevardCanastota, NY 13031, USAPhone: 315-697-<strong>JUMO</strong>1-800-554-<strong>JUMO</strong>Fax: 315-697-5867e-mail: info@jumo.usInternet: www.jumo.usData Sheet 20.2565Page 3/12Detection of depositsDeposit detection can be activated for 4-electrode cells.During normal operation, it can happen thatdeposits form on electrodes. This has theresult that a lower concentration is displayedthan actually present. With activated “depositdetection” function, the instrument tells youwhen the cell needs to be serviced.Auto-rangeFor some processes, the availability of twomeasuring ranges is advantageous, forinstance for rinsing or regenerationprocesses.What is usually required here, is the preciseacquisition of a low conductivity. Rinsing orregeneration, however, involves a muchhigher conductivity, which could lead to anout-of-range condition (error). This situation isnot just unsatisfactory, but may even bedangerous. Thanks to the auto-rangefunction, two measuring ranges can bedetermined. The instrument then switchesbetween them in a defined manner.Binary inputThe following functions can be activatedthrough the binary input:- Activate key inhibitWhen this function has been activated,operation from the keys is no longerpossible.- Activate HOLD modeAfter activating this function, the outputs(analog and relay) adopt the states thathave previously been defined.- Alarm suppression (controller alarm only)This function temporarily deactivates thealarm generation via the relay (has to beconfigured accordingly).Linking the corresponding terminals bymeans of a floating contact (e. g. relay) willactivate the pre-defined function.Analog OutputsControl functionsThe relays can have functions assigned thatare configured via parameters. The controlfunction is freely programmable as P, PI, PD orPID action.Analog outputsUp to two analog outputs are available,configurable as analog process value outputor continuous controller. The “analog processvalue output” function can be assigned to theprinciple measurement variable or to thetemperature. The “continuous controller”function can only be assigned to the principlemeasurement variable. Both functions can becombined.With the analog process value output, therange start and end values are freelyselectable.The response of the outputs to over/underrange, HOLD and calibration is freelyprogrammable.Simulation function:The analog process value outputs can befreely set in the manual (“Hand”) mode.Application:“Dry-run” start-up of the plant, troubleshooting,servicingRelay outputsTwo relay changeover contacts are availablefor the principle measurement variable and/ortemperature.The following functions can be programmed:- Switching direction(min/max)- Limit controller(pull-in/drop-out delay, hysteresis)- Pulse width output(see control functions)- Pulse frequency output(see control functions)There are up to 2 analog outputs available.The following functions can be selected:Output Analog process value output Continuous controllerPrinciple measurementvariablePrinciple measurementTemperaturevariable1 X - X2 - X XWith the analog process value output, the range start and end values are freely selectable.The response of the outputs to over/underrange, alarm and calibration is freely programmable.Simulation function:The analog process value outputs can be freely set in the manual ("Hand") mode.Application:"Dry run" start-up of the plant, troubleshooting, servicing.- Modulating controller function(see control functions)- Limit comparators(pull-in/drop-out delay, hysteresis)- Pulse functionThe output switches on briefly whenreaching the switching point and then offagain.- Alarm- Sensor or range error- Response to alarm, over/underrange,calibration and HOLDContact functionsMAX limit comparatorOffMIN limit comparatorOnAlarm window 1OffHysteresisAlarm window 2OffHysteresisOnLimitSetpointHysteresisLimitSetpointDistanceLimitSetpointHysteresisDistanceLimitSetpointOffOnpHpHOnpHpH10.07/00477047

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!