12.07.2015 Views

FX-500 Catalog - Panasonic Electric Works Corporation of America

FX-500 Catalog - Panasonic Electric Works Corporation of America

FX-500 Catalog - Panasonic Electric Works Corporation of America

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

FUNCTIONSelectable interference preventionIn addition to the automatic interference prevention function which is enabledthrough the optical communication <strong>of</strong> cascade connected amplifiers, analternate frequency interference prevention function is also incorporated. Soeven for layouts where optical communication cannot be carried out,switching <strong>of</strong> emission frequencies allows interference prevention.Automatic interference prevention(When amplifiers are cascade connected)Alternate frequency interference prevention(When amplifiers cannot be cascade connected)An optical communication function allowssensors to be adjusted simultaneouslyThe optical communication function allows the data that is currently set tobe copied and saved all at once for all amplifiers connected together fromthe right side. This greatly reduces troublesome setup tasks and makessetup much smoother.Optical communicationEmission frequency 1Emission frequency 2Emission frequency 3Single copy & save operationfor all amplifiers* Refer to specifications for details <strong>of</strong> number <strong>of</strong> sensors allowed in interference prevention.No need to specify a main unit or sub unitAll <strong>FX</strong>-<strong>500</strong> amplifiers can be used as either a main unit or a sub unit. Justuse a main cable or a sub cable to distinguish the two. This reduces thecosts <strong>of</strong> inventory management.Optical communicationwindowWire-saving, space-savingThe quick-connection cables enable reduction in wiring. The connectionsand man-hours required for the relay terminal block setup can be reducedand valuable space is saved.The same part numbercan be used as eithera main unit or sub unit!Up to 16 sensors allowed in power-supply wire-savingSub cable<strong>FX</strong>-501□<strong>FX</strong>-502□Main cable (3-core)CN-73-C□Sub cable (1-core)CN-71-C□Main cable (4-core)CN-74-C□Sub cable (2-core)CN-72-C□Main cableDisconnection is possible withoutmoving the amplifier sidewaysPower supplycableOutput line 1Output line 2CN-73/74-C□CN-71/72-C□Output line 16* Connection <strong>of</strong> up to 16 units with <strong>FX</strong>-400 / DPS-400 / LS-400 is possible.* Up to 12 sensors in optical communication.PRO mode functionsResponse time settingCode settingTimer settingDisplay adjustment settingPRO1Hysteresis settingShift amount settingPRO5Reset settingCUSTOM settingEmission power settingInterference prevention settingTimer range settingNormal modePRO2PRO3Teaching lock settingDigital display item settingDigital display turning on settingECO settingPeriod hold settingData bank loading settingData bank saving settingBack up settingPRO6Sensing output modeWindow comparator mode *3Rising differential modeTrailing differential modeHysteresis modeForced ON output modeForced OFF output modeSelf-diagnosis output mode *4Answer back output mode *5Input / output setting *1Logical operation setting *6PRO4Copy settingCopy action settingCopy lock settingCommunication protocol settingPRO7Setting <strong>of</strong> thresholdvalue trackingSetting <strong>of</strong> threshold trackingSensing output settingStorage cycle settingAlgorithm settingExternal input setting *2*1: <strong>FX</strong>-502(P) only *2: <strong>FX</strong>-502(P) and <strong>FX</strong>-505(P)-C2 only *3: Output 1 only*4: Output 2 only <strong>of</strong> <strong>FX</strong>-502(P) and <strong>FX</strong>-505(P)-C2 *5: Output 2 only <strong>of</strong> <strong>FX</strong>-505(P)-C2*6: <strong>FX</strong>-501(P) can do a part <strong>of</strong> operations.<strong>FX</strong>-<strong>500</strong>SERIES08

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!