NAVIGATION LIGHTS USERS GUIDE - Ysebaert
NAVIGATION LIGHTS USERS GUIDE - Ysebaert
NAVIGATION LIGHTS USERS GUIDE - Ysebaert
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
aqua signalaqua signal - GENERAL INFORMATION - CABLE SECTIONSCable sectionsIn order to ensure that the brightness /range of the navigation lightsconforms to regulations, sufficientcable section should be used for thepower supply of the navigation lights.The selection of the cable sections tobe used is dependent on the length ofthe supply cable. As an aid you canfind the rough guiding values in thetable depicted here.No liability assumed for informationgiven.Cablemax. distance to power source meterØ mm² 2 m 4 m 6 m 8 m 10 m6 V, 10 W 0,75 0,75 1,50 1,50 2,506 V, 25 W 1,50 2,50 4,00 4,00 6,0012 V, 10 W 0,75 0,75 0,75 0,75 0,7512 V, 25 W 0,75 0,75 0,75 1,50 1,5024 V, 10 W 0,75 0,75 0,75 0,75 0,7524 V, 25 W 0,75 0,75 0,75 0,75 0,75Cablemax. distance to power source meterØ mm² 12 m 14 m 16 m 18 m 20 m 25 m6 V, 10 W 2,50 2,50 4,00 4,00 4,00 6,006 V, 25 W 6,00 6,0012 V, 10 W 0,75 0,75 1,50 1,50 1,50 1,5012 V, 25 W 1,50 2,50 2,50 2,50 2,50 4,0024 V, 10 W 0,75 0,75 0,75 0,75 0,75 0,7524 V, 25 W 0,75 0,75 0,75 0,75 0,75 1,50Cablemax. distance to power source meterØ mm² 30 m 35 m 40 m 45 m 50 m6 V, 10 W 6,00 6,00 6,006 V, 25 W12 V, 10 W 1,50 2,50 2,50 2,50 2,5012 V, 25 W 4,00 6,00 6,00 6,00 6,0024 V, 10 W 0,75 0,75 0,75 0,75 0,7524 V, 25 W 1,50 1,50 1,50 1,50 1,5086Light on Board 2007 / 2008