12.07.2015 Views

60 Series

60 Series

60 Series

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

DSC noise of less than 1µWSample: Polypropylene 30μgThe DSC-<strong>60</strong> realizes noise level of less than 1µ W byusing the high-resolution A/D converter, reexaminingthe temperature control theory, and improving thermalconductivity from the heater. Accordingly, a trace ofsample can be measured and a slight change can bedetected as a large peak.New furnace unit of DSC-<strong>60</strong>The DSC-<strong>60</strong> comes standardwith a furnace which is reducedheat capacity and a liquidnitrogen cooling chamber.These features improve thetemperature controlHeaterperformance and allow rapidcooling.FurnaceHeat FlowHeat Transfer PlateLiquid NitrogenHeat Radiating FinsCooling FansFast coolingPrecise temperature control24°C–50°C–100°C(–10°C/min)0.0 2.0 4.0 6.0Time [min]–140°CTemp°C50.00.0–50.0–100.0–150.0The DSC-<strong>60</strong> hasattained fast coolingby dramaticallyreducing furnace heatcapacity andcombining the furnaceand the cooling devicein one unit.The sample is cooledby 35°C/min. at 0°Cand by 10°C/min.at -70°C.Other modelsAs result of the newdevelopment of a newfurnace and temperaturecontrol unit based onthe "heating whilecooling" concept,precise temperaturecontrol becameavailable. This enablesusers to create multiplestep temperatureprograms for variousapplications.Sample setting temperature optionTemperatureSamplesettingtemperatureRoomtemperatureIncrease/decreasetemperaturequickly–150°CHold the sample settingtemperature(Insert the sample.)Increase/decreasetemperature byfollowing the givenprogramStart measurementTimeDSC-<strong>60</strong> SpecificationsMeasurement principleTemperature rangeMeasurement rangeCooling timeNoise levelAtmosphereDimensions and weightPower supplyHeat-flux type-140 to <strong>60</strong>0°C (With standard cooling chamber and using liquid nitrogen)± 40 mWApprox. 6 min. (<strong>60</strong>0°C to 40°C using liquid nitrogen)1 μW (rms, when held at 150°C)Air and inert gasW: 320 x D: 500 x H: 290 (mm), 21kgAC 100V, 120V, 230V 800VA, 50/<strong>60</strong>HzWhen the furnace temperature is below theambient temperature, it is generally difficult toset a sample pan without causing frostformation on the furnace surface. To solve suchinconvenience, the DSC-<strong>60</strong> provides a newsample setting temperature option.5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!