RAYSTAT-ECO-10Proportional ambient sensing controller <strong>for</strong> use innon-hazardous areasSensor type: 3-wire RTD (Pt 100)Mounting: surface mountedSetpoint range: 0°C to +30°CSwitching capacity: 25AIncludes an alarm relay to allow remote indication ofsystem statusPart number: 145232-000R AY S TAT-C O N T R O L -1 0RAYSTAT-CONTROL-10Electronic surface sensing thermostat <strong>for</strong> use innon-hazardous areasSensor type: 3-wire RTD (Pt 100)Mounting: surface mounted, or pipe mounted usingSB-100 or SB-101(option)Setpoint range: 0°C to +150°CSwitching capacity: 25AIncludes an alarm relay to allow remote indication ofsystem statusPart number: 828810-00018 DOC-565 Rev.2 03/11AT-TS-13AT-TS-14RAYSTAT-EX-02RAYSTAT-EX-03RAYSTAT-EX-04Electronic ambient sensing thermostat <strong>for</strong> use innon-hazardous areasSensor type: PTC KTY 83-110Mounting: wall mounted, or pipe mounted usingSB-110 or SB-111(option)Setpoint range: -5°C to +15°CSwitching capacity: 16APart number: 728129-000Electronic surface sensing thermostat <strong>for</strong> use innon-hazardous areasSensor type: PTC KTY 83-110Mounting: surface mounted, or pipe mounted usingSB-110 or SB-111 (option)Setpoint range: 0°C to +120°CSwitching capacity: 16APart number: 648945-000Mechanical surface sensing thermostat <strong>for</strong> use inhazardous areasSensor type: bulb and capillarySensor length: 3 mApproval: II 2GD Ex d IIC T6 (Ta –40°C to +60°C)Ex tD A21 IP6X T80°C (-40°C ≤ Tamb ≤ +60°C)Mounting: on pipe with SB-100 or SB-101 (option) orsurface mountedSetpoint range: –4 to +163°CSwitching capacity: 22 ACable gland (3/4" NPT) to be ordered separately: <strong>for</strong> armouredcable use GL-33; <strong>for</strong> non-armoured cable use GL-34Part number: 404385-000Electronic surface sensing thermostat <strong>for</strong> use in hazardousareasSensor type: 2 wire RTD (Pt 100)Sensor length: 2 mApproval: II 2 GD T=85°C Ex emia IIC T6(–50°C ≤ Ta ≤ 55°C)Mounting: on pipe with SB-100 or SB-101 (option) orsurface mountedSetpoint range: 0 to +499°CSwitching capacity: 16 APart number: 333472-000Electronic ambient sensing thermostat <strong>for</strong> use in hazardousareasApproval: II 2 GD T=85°C Ex emia IIC T6(–50°C ≤ Ta ≤ 55°C)Mounting: on pipe with SB-100 or SB-101 (option) orsurface mountedSetpoint range: 0 to +49°CSwitching capacity: 16 APart number: 462834-000

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!