12.07.2015 Views

058C-059C-060C-0706 FT5BD SS HP TSL.indd - Nordyne

058C-059C-060C-0706 FT5BD SS HP TSL.indd - Nordyne

058C-059C-060C-0706 FT5BD SS HP TSL.indd - Nordyne

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SYSTEM HEATING & COOLING CAPACITIES (Continued)14+ SEER — High Efficiency — Single PhaseOutdoorUnitIndoor Piston CoilCoolingCapacityBTUH SEER EERHeating CapacityBTUH @47 F HSPF SCFMIndoorOrifice018K C5B(A,H)-024(U,C)-B+TDR+LLS+VSB-B 18,100 14.0 12.2 16300 8.5 720 0.051024K C5B(A,H)-025(U,C)-B+TDR+LLS+VSB-B 24,800 14.0 12.4 22000 8.5 720 0.061030K C5B(A,H)-030(U,C)-B+TDR+LLS+VSB-B 29,400 14.0 12.5 28200 8.5 860 0.069036K C5B(A,H)-036(U,C)-B+TDR+LLS+VSB-B 35,800 14.0 12.4 35800 8.5 1,125 0.078042K C5B(A,H)-042(U,C)-B+TDR+LLS+VSB-B 40,500 14.0 12.3 41500 8.5 1,375 0.083048K C5B(A,H)-049(U,C)-C+TDR+LLS+VSB-C 46,000 14.0 12.4 46500 8.5 1,555 0.090OutdoorUnitIndoor PistonAir Handler B5VM-CoolingCapacityBTUH SEER EERHeating CapacityBTUH @47 F HSPF SCFMIndoorOrifice018K 024K-B+LLS 18,100 14.0 12.2 16300 8.5 720 0.051024K 025K-B+LLS 24,800 14.0 12.4 22000 8.5 720 0.061030K 030K-B+LLS 29,400 14.0 12.5 28200 8.5 860 0.069036K 036K-B+LLS 35,800 14.0 12.4 35800 8.5 1,125 0.078042K 042K-B+LLS 40,500 14.0 12.3 41500 8.5 1,375 0.083048K 049K-C+LLS 46,000 14.0 12.4 46500 8.5 1,555 0.090OutdoorUnitIndoor PistonAir Handler B5BM-CoolingCapacityBTUH SEER EERHeating CapacityBTUH @47 F HSPF SCFMIndoorOrifice018K 024K-B+LLS+VSB-B 18,100 14.0 12.2 16300 8.5 720 0.051024K 025K-B+LLS+VSB-B 24,800 14.0 12.4 22000 8.5 720 0.061030K 030K-B+LLS+VSB-B 29,400 14.0 12.5 28200 8.5 860 0.069036K 036K-B+LLS+VSB-B 35,800 14.0 12.4 35800 8.5 1,125 0.078042K 042K-B+LLS+VSB-B 40,500 14.0 12.3 41500 8.5 1,375 0.083048K 049K-C+LLS+VSB-C 46,000 14.0 12.4 46500 8.5 1,555 0.090OutdoorUnitIndoor TXV CoilCoolingCapacityBTUH SEER EERHeating CapacityBTUH @47 F HSPF SCFM018K C5B(A,H)-T24(U,C)-B+TDR+VSB-B 18,100 14.0 12.2 16300 8.5 720024K C5B(A,H)-T25(U,C)-B+TDR+VSB-B 24,800 14.0 12.4 22000 8.5 720030K C5B(A,H)-T30(U,C)-B+TDR+VSB-B 29,400 14.0 12.5 28200 8.5 860036K C5B(A,H)-T36(U,C)-B+TDR+VSB-B 35,800 14.0 12.4 35800 8.5 1,125042K C5B(A,H)-T42(U,C)-B+TDR+VSB-B 40,500 14.0 12.3 41500 8.5 1,375048K C5B(A,H)-T49(U,C)-C+TDR+VSB-C 46,000 14.0 12.4 46500 8.5 1,555OutdoorUnitIndoor TXVAir Handler B5VM-CoolingCapacityBTUH SEER EERHeating CapacityBTUH @47 F HSPF SCFM018K T24K-B 18,100 14.0 12.2 16300 8.5 720024K T25K-B 24,800 14.0 12.4 22000 8.5 720030K T30K-B 29,400 14.0 12.5 28200 8.5 860036K T36K-B 35,800 14.0 12.4 35800 8.5 1,125042K T42K-B 40,500 14.0 12.3 41500 8.5 1,375048K T49K-C 46,000 14.0 12.4 46500 8.5 1,555OutdoorUnitIndoor TXVAir Handler B5BM-CoolingCapacityBTUH SEER EERHeating CapacityBTUH @47 F HSPF SCFM018K T24K-B+VSB-B 18,100 14.0 12.2 16300 8.5 720024K T25K-B+VSB-B 24,800 14.0 12.4 22000 8.5 720030K T30K-B+VSB-B 29,400 14.0 12.5 28200 8.5 860036K T36K-B+VSB-B 35,800 14.0 12.4 35800 8.5 1,125042K T42K-B+VSB-B 40,500 14.0 12.3 41500 8.5 1,375048K T49K-C+VSB-C 46,000 14.0 12.4 46500 8.5 1,555The ratings shown above are for the highest sales volume combination. Additional ratings, including mix-matches may be found in the current editionof the ARI Directory of Certifi ed Unitary Equipment. Verifi cation of ratings not printed in the current edition of the Directory may be obtainedonline at the ARI website (www.ari.org/).6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!