(2) .75" or 1"Conduitknockouts39"34.5"32"1.5"2.25"Rev. B: 5/22/06Rev. A: New<strong>Air</strong> <strong>Flow</strong>(2) 1.5" or 2"ConduitknockoutsTop View1.75"18"5"39"2.25"Output CBBattery CBInput CB(3) 1.5" or 2"Conduitknockouts3.25"68"(3) .75" or 1"ConduitknockoutsDC TBFront View34.8"Output TB(Optional)Reserve Aux.Input TBInput TB(4) 0.68" Dia. Typ.Floor Mounting HolesSide View(Both Sides Typ.)46"NOTE:1. Matching Battery Cabinet has same physical dimensions.(see doc #: 6001-032-05, -06, 07 for Battery Cabinet layouts).2. Both UPS and battery cabinet have top and sides conduit entryand same floor mounting hole dimensions.3. Consult factory for size and number of battery cabinet.4. Optional Seismic Brackets (P/N: 9100-1317-02) are available.When seismic bracket used, 8" minimum space requiredbetween cabinets. Anchoring hardware to be supply by customer.5. Optional racks (P/N: 9100-1429-XX) available for stack batterycabinets. (see doc #: 6001-032-07).6. Consult factory for different back-up times and number of batterycabinet require.7. <strong>Air</strong> intake and exhaust can not be blocked, allow 12-15 inchesclearance.Bottom View14"Drawn by: Date:Chun Chi 2/23/07Chkd.:Date:Appvd.: Date:Three Phase UPS InstallationInstallationDrawing6001-032-03 Rev C


Rev. D: 10/08/06Add 62.5 kVA12"39" 12"39"1"UPS CabinetBattery Cabinet 118"10 kVA, 8 kW18"12"39" 12"1" 1"39" 39"UPS CabinetBattery Cabinet 1 Battery Cabinet 218"18"15 kVA, 12 kW20 kVA, 16 kW25 kVA, 20 kW30 kVA, 24 kW12"39" 12"1" 1"39" 39" 39" 1"17.12"UPS CabinetHutch Hutch HutchBattery Cabinet 1 Battery Cabinet 2Battery Cabinet 312"18"40 kVA, 32 kWStandard with Hutch18"12"39" 12"*40 kVA, 32 kW with optional 48” cabinet1"39" 39"1"39"50 kVA, 40 kW1" 1"39"UPS CabinetBattery Cabinet 1Battery Cabinet 2Battery Cabinet 3Battery Cabinet 418"18"12"39" 12"1"39" 39"1"39"1" 1"39"62.5 kVA, 50 kW39"1"UPS CabinetBattery Cabinet 1 Battery Cabinet 2Battery Cabinet 3Battery Cabinet 4Battery Cabinet 518"18"Removable Hutch tohouse 1 Battery for40 kVA (32 kW) only(17.12”W x 11”H x 12”D)Typical Battery CabinetBatteryCB39"68"NOTE:1. Service Clearance Areas are shaded.2. Each battery cabinet includes 1 C/B.3. Each battery cabinet have top and both sides conduit entry and same floormounting hole dimensions as UPS cabinet. (See doc #: 6001-032-03 for detail).4. Optional Seismic Brackets (P/N: 9100-1317-02) are available.When seismic bracket used, 8" min. space required between cabinets.Anchoring hardware to be supply by the customer.5. Optional racks (P/N: 9100-1429-XX) available (except 40 KVA, 32 KW unit)for stack battery cabinets. (see doc #: 6001-032-07).6. Consult factory for different back-up times and number of battery cabinet require.Drawn by:Date:Chun Chi 2/1/06Chkd.:Date:UPS & Battery Cabinet Installations18"Appvd.:Date:3 Phase UPS6001-032-05 Rev D


Rev. D: 10/08/06Add 62.5 kVATypical Battery CabinetRemovableHutch to house1 Battery for40 kVA (32 kW) only(17.12”W x 11”Hx 12”D)BatteryCB10 kVA, 8 kW39"18"68"NOTE:1. Service Clearance Areas are shaded.2. Each battery cabinet includes 1 C/B.3. Each battery cabinet have top and bothsides conduit entry and same floormounting hole dimensions as UPS cabinet.(See doc #: 6001-032-03 for detail).4. Optional Seismic Brackets(P/N: 9100-1317-02) are available.When seismic bracket used, 8" min.space required between cabinets.Anchoring hardware to be supplyby the customer.5. Optional racks (P/N: 9100-1429-XX)available (except 40 KVA, 32 KW unit)for stack battery cabinets.(See doc #: 6001-032-07).6. Consult factory for different back-up timesand number of battery cabinet require.40 kVA, 32 kWStandard with Hutch12"18"*40 kVA, 32 kWwith optional 48” cabinet50 kVA, 40 kWBatteryCabinet1BatteryCabinet339"UPS CabinetBatteryCabinet2*BatteryCabinet436" 18"1" 1"18" 39" 39"Hutch17.12"UPSCabinetBatteryCabinet139"UPSCabinetBatteryCabinet139"62.5 kVA, 50 kW12"18"BatteryCabinet136" 18"15 kVA, 12 kW20 kVA, 16 kW25 kVA, 20 kW30 kVA, 24 kW39"UPS CabinetBatteryCabinet21"18" 39"18"BatteryCabinet2HutchBatteryCabinet336"Hutch18"39"18"UPSCabinetBatteryCabinet2BatteryCabinet4BatteryCabinet1BatteryCabinet3*BatteryCabinet536" 18"39"1" 1"39" 39"18"36" 18"Drawn by: Date:Chun Chi 2/1/06Chkd.:Date:UPS & Battery Cabinet InstallationsAppvd.:Date:3 Phase UPS6001-032-06 Rev D


Rev. D: 10/08/06Add 62.5 kVA39"TypicalBatteryCabinetBatteryCB68"10 kVA, 8 kW15 kVA, 12 kW20 kVA, 16 kW25 kVA, 20 kW30 kVA, 24 kWBatteryCabinet1BatteryCabinet218"NOTE:1. Stackable Rack is not available for40 kVA, 32 kW units with Hutch option.2. Service Clearance Areas are shaded.3. Each battery cabinet includes 1 C/B.4. Each battery cabinet have top and both sides conduit entryand same floor mounting hole dimensions as UPS cabinet.(see doc #: 6001-032-03 for detail).5. Optional Seismic Brackets (P/N: 9100-1317-02)are available. When seismic bracket used, 8" min. spacerequired between cabinets. Anchoring hardware to besupply by the customer.6. Consult factory for different back-up times and number ofbattery cabinet require.7. The UPS cabinet can be installed on left or right.UPSCabinet51"W x 30.25"DService ClearanceUPSCabinetBatteryCabinet1111"W x 30.25"DService ClearanceOptional Racks(P/N: 9100-1429-XX)*40 kVA, 32 kWwith optional 48” cabinet50 kVA, 40 kW62.5 kVA, 50 kWBatteryCabinet2BatteryCabinet*1UPSCabinetBatteryCabinet449"BatteryCabinet212"39"4"56"BatteryCabinet*1BatteryCabinet366.25"123.5"142"UPSCabinetBatteryCabinet3BatteryCabinet456"12"28.25"168"W x 30.25"DService ClearanceBatteryCabinet5Typical Rack Mounting Bottom ViewUPS Cabinet39" 4"BatteryCabinet56"54"BatteryCabinet56"4"4"28.25"26.25".56 Dia. (typ.)Drawn by:Date:Chun Chi 2/1/06Chkd.:Appvd.:Date:Date:UPS & Battery Cabinet Installationswith Stackable Rack3 Phase UPS6001-032-07 Rev D


Rev. A: 2/23/071NTB101234INPUTPOWER3 PHASETVSSINPUTCIRCUITBREAKERINPUTCONTACTORINPUTXFMR2BATTERYCIRCUITBREAKEROUTPUTXFMRSTATICSWITCHINVERTERSTATICSWITCHOUTPUTCIRCUITBREAKERINPUTMAINT.BYPASSSWITCHAUX OUTPUT CBsTB111234NOUTPUTPOWER3 PHASEBATTERYCABINETOptional12Line removed when External Reserve Input <strong>Power</strong> is in use.Use for different Input and Output Voltage unit.Batt.Cab 1Batt.Cab 2Batt.Cab 3Batt.Cab 4Batt.Cab 5NOTE: Optional External Wrap-around Bypass Switch is available.Single Line DiagramSingle Input6001-032-11 Rev A


Rev. C: 2/23/073RESERVE INPUTPOWER SOURCE12N34CONTACTOR1NTB101234INPUTPOWER3 PHASETVSSINPUTCIRCUITBREAKERINPUTCONTACTORINPUTXFMR2BATTERYCIRCUITBREAKEROUTPUTXFMRSTATICSWITCHINVERTERSTATICSWITCHOUTPUTCIRCUITBREAKERINPUTMAINT.BYPASSSWITCHAUX OUTPUT CBsTB111234NOUTPUTPOWER3 PHASEOptionalBATTERYCABINET1Line removed when External Reserve Input <strong>Power</strong> is in use.2Use for different Input and Output Voltage unit.3 Reserve input voltage must be same as UPS output voltage.NOTE: Optional External Wrap-around Bypass Switch is available.Batt.Cab 1Batt.Cab 2Batt.Cab 3Batt.Cab 4Batt.Cab 5Single Line DiagramDual Input Wye/Wye6001-032-04 Rev C


1* Cabinet 1, 48 inch tallRev. A: ECO# 8267RESERVEINPUTPOWER(plus Gnd)GNDMAININPUTDELTAGNDTB1012341234/ WYEXFMRTVSSINPUTCIRCUIT INPUTBREAKER CONTACTOR12341234RESERVEBYPASS POWERFrom InternalTransformerINPUTXFMR(N)CONTACTORBATTERYCIRCUITOUTPUTXFMRSTATICSWITCHINVERTERSTATICSWITCHOUTPUTCIRCUITBREAKERINPUTMAINT.BYPASSSWITCHTB111234OUTPUTPOWER3 PHASEBATTERYCABINET1 Optional External ∆ - WYE XFMR when the reserve is 3 wire Delta input.Batt.Cab 1Batt.Cab 2Batt.Cab 3Batt.Cab 4Batt.Cab 5Single Line DiagramDual Input Delta/Delta6001-032-10 Rev C