ContentsDo’s and Don’ts 2The product 3Subfloor considerations 4<strong>Installation</strong> layouts 9Installing multiple heaters 10<strong>Installation</strong> steps 11-19Spacing guides 13-14Warranty / Terms and Condition 20-21Warranty registration form 22Do’s & Dont’sThe cable must be spaced evenly at all times to ensure an evenly heatedfloor. The bend radius of the wire must NOT be less than 2” (50mm).The cables must never touch or cross each other (min separation is2”[50mm]).The cable must not be cut, damaged or shortened.The entire cable, including joints, must be laid under the floor slab.<strong>Installation</strong> of the cable onto a new concrete floor should not becarried out for approximately 30 days to allow the concrete to cure.Do not install the cable up walls.NEVER install cables directly onto insulation boards.If these instructions are followed, you should have no problems,however if you require assistance at any stage, please call ourhelpline on:21-888-927-6333 (US)1-888-592-7687 (Canada)