12.07.2015 Views

Series 1, 2, 3 and 4 - Powerpipe

Series 1, 2, 3 and 4 - Powerpipe

Series 1, 2, 3 and 4 - Powerpipe

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SINGLE PIPES 3:106Curved pipes<strong>Series</strong> 1, 2, 3 <strong>and</strong> 4deflectionPN 16/PN25CURVED PIPES 1123, 1124, 1223, 1224, 1323, 1324, 1423, 1424Single pipesMax. deflectionDN L = 12 m L = 16 m Note25 - 80 35 o To be bent at installation site80 - 100 35 o Bent at <strong>Powerpipe</strong> works125 - 150 30 o 25 o Bent at <strong>Powerpipe</strong> works200 25 o 33 o Bent at <strong>Powerpipe</strong> works250 25 o 33 o Bent at <strong>Powerpipe</strong> works300 20 o 25 o Bent at <strong>Powerpipe</strong> works350 14 o 23 o Bent at <strong>Powerpipe</strong> works400 11-(18) o 15-(22) o Bent at <strong>Powerpipe</strong> works *450 7-(11) o 11-(18) o Bent at <strong>Powerpipe</strong> works *500 5-(9) o 8-(12) o Bent at <strong>Powerpipe</strong> works *600 – 8 o Bent at <strong>Powerpipe</strong> works*700 – 4 o Bent at <strong>Powerpipe</strong> works** See note below concerning wall thickness. wall thickness below. In paranteses; the specified values relatesthickness higher than st<strong>and</strong>ard.Accuracy of manufacture DN 100 - 200 +/- 2°DN 250 - 600 +/- 1°Steel pipes:For the manufacturing either seamless steel pipes or longitudinally welded steel pipes are used.DN 450, DN 500, DN 600 <strong>and</strong> DN700 steel pipes with extra wall thickness will be used. Increasedwall thickness for smaller dimensions will allow deflection exceeding above normal max. deflection.This can be delivered on request. However, this means increased prices <strong>and</strong> longer deliverytime. For larger sizes (DN700-900) segment-welded curved pipes can be offered.For manufacturing technical reasons, the alarm wires placed in neutral position, ie c. at. 12 <strong>and</strong> 6.Article no. series 11123-DN-xxx-000 for 12 m pipe length1124-DN-xxx-000 for 16 m pipe lengthArticle no. series 21223-DN-xxx-000 for 12 m pipe length1224-DN-xxx-000 for 16 m pipe lengthArticle no. series 31323-DN-xxx-000 for 12 m pipe length1324-DN-xxx-000 for 16 m pipe lengthArticle no. series 41423-DN-xxx-000 for 12 m pipe length1424-DN-xxx-000 for 16 m pipe lengthxxx = degreesAn example of how to order:Curved pipe series 1, L = 12 m with dim DN 200 <strong>and</strong> curved 15 ohas Article No. 1123-200-015-000, Deflection shall be stated in a separate line of text.Edition 2013

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!