12.07.2015 Views

Solartron on-line Viscometers - Measurement Resources

Solartron on-line Viscometers - Measurement Resources

Solartron on-line Viscometers - Measurement Resources

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Covimat 105-DC rangeApplicati<strong>on</strong>: For high temperatures and pressuresDC40DThe DC40D range is suitable for c<strong>on</strong>tinuousmeasurement of viscosity at high temperatures and highpressures. To prevent heat losses - and to avoidcrystallisati<strong>on</strong> and hardening processes at lowthroughputs or at high temperatures - the DC40D cellshave an isothermal (jacketed) wall. A range of flangeopti<strong>on</strong>s is available and for direct measurement or theproduct temperature, a thermowell is provided for atemperature sensor.DC40EThe DC40E range is designed for c<strong>on</strong>tinuousmeasurement of viscosity at low pressures and hightemperatures. A thermowell is provided to accept atemperature sensor for direct measurement of theproduct temperature. There is a range of flangeopti<strong>on</strong>s.Specificati<strong>on</strong>sViscosity rangeAchievable accuracyMax. temp. of productMax. pressureMax. flow rateMaterial of measuring cellMaterial of sealApprox. weight of cell +adapter (depends <strong>on</strong> flange)*Twin gap measuring cellsCovimat DC40E250ºC (482ºF)25 bar (362 psig)or to flange rating9.5 kg (20.95 lb)1 to 720,000cP± 1% FS40 l/min (10.57 USgall/min)316L stainless steelAsbestos freeCovimat DC40D300ºC (572ºF)170 bar (2,465 psig)or to flange rating18 kg (39.69 lb)Viscosity ranges (via interchangeable cylinders)Covimat DC40E Covimat DC40DDia. (mm)DS*5957513524Standard (cP)1 to 1909 to 92020 to 2,00060 to 6,000240 to 24,000720 to 72,000with Z opti<strong>on</strong> (cP)10 to 1,90090 to 9,200200 to 20,000600 to 60,0002,400 to 240,0007,200 to 720,00044mm (1.73in)44mm (1.73in)195mm(7.68in)210mm(8.27in)138mm(5.43in)145mm(5.71in)


Covimat 105 Ordering MatrixCovimat <strong>Measurement</strong> Head4-20mA output for DD Flow CellsDescripti<strong>on</strong>Order No.ATEX approved 81051CTSignal C<strong>on</strong>verters (opti<strong>on</strong>al)TypeOrder No.7950 wall (Klipp<strong>on</strong>) 7950 AA7951 panel (Klipp<strong>on</strong>) 7951 AA7951 panel (D-Type) 7951 AB Covimat <strong>Measurement</strong> Head4-20mA output for TO & DC flow cellsDescripti<strong>on</strong> Order No.ATEX approved81051ATATEX approved (Z versi<strong>on</strong>) 81051BTCoupling piece 00112810PT100 Temp. Sensor(opti<strong>on</strong>al) 81053748ACovimat TO Immersi<strong>on</strong> SystemImmersi<strong>on</strong> length Order No.200mm (7.87in) 00112812300mm (11.81in) 00112813500mm (19.68in) 00112814Covimat DC40D Flow BeakersDescripti<strong>on</strong> Order No.DN25 PN100 RTJ 81053AAA1½” ANSI 150 RF 81053AAB1½” ANSI 600 RF 81053AAC1½” ANSI 900 RF 81053AADDN32 PN40 RF 81053AAEDN25 PN100 RF 81053AAFCovimat DD Flow CellDescripti<strong>on</strong> Order No.Measuring cell(excl. cylinder/bob) 00112405Covimat DC40E Flow BeakersDescripti<strong>on</strong> Order No.2” ANSI 150 RF 81053BABDN50 PN40 RF 81053BAE2” TRI CLAMP 81053BAG2” IDF 81053BAHCylinders/bobsRangeOrder No.1 - 460 cP * 001124435 - 1,350 cP * 0011244410 - 3,100 cP * 0011244515 - 5,000 cP 0011244630 - 8,800 cP * 0011244740 - 11,200 cP 0011244850 - 13,200 cP 00112449* Twin gap measuring cellsCylinders/bobsSize Order No.69.5mm 0011235068mm 0011234963mm 0011234846mm 0011234731mm 00112273Cylinders/bobsSize Order No.24mm 0011230935mm 0011230751mm 0011230557mm 0011230359mm 00112302Double-split 00112242


Installati<strong>on</strong> accessoriesCorrect installati<strong>on</strong> is a key factor in the quest foraccurate l<strong>on</strong>g-term measurement, particularly whereviscosity is used as a critical c<strong>on</strong>trol parameter andwhere <strong>line</strong> values must be referred to base c<strong>on</strong>diti<strong>on</strong>s.Flow through chambers are available with 1” or 2” NBinlet/outlet tubes, with a choice of weld ends,compressi<strong>on</strong> fittings or flanges, and an opti<strong>on</strong>al thermaljacket.The flow through chamber is designed for installati<strong>on</strong> asa local fast loop (slipstream) <strong>on</strong> a main pipe<strong>line</strong>, andgives the following advantages:• minimizes the need for <strong>on</strong>-site calibrati<strong>on</strong>• improves accuracy• enhances viscosity referrals• increases tolerance of solids and entrained gas• reduces maintenanceFor direct pipe<strong>line</strong> fitting and improved thermalperformance, <str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g>’s range of prepared collars(weldolets) are available for pipe diameters of 4”, 6”, 8”or 10” nominal bore.See data sheet B782703 for more detailsMore details of <str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g> transducers, signal c<strong>on</strong>verters and flow computers are given in the following brochures:Density transducersGas Density and Specific Gravity Products795x Series Signal C<strong>on</strong>verters795x Series Flow Computers for the gas industry795x Series Flow Computers for oil and refined productsInstallati<strong>on</strong> accessoriesIP7003B1253B1251B1248B1249B782703<str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g> Mobrey Limited158 Edinburgh Avenue SloughBerks UK SL1 4UETel: 01753 756600Fax: 01753 823589e-mail: sales@solartr<strong>on</strong>.comwww.solartr<strong>on</strong>mobrey.com<str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g> Mobrey19408 Park Row, Suite 320,Houst<strong>on</strong> TX 77084 USATel: 281 398 7890Fax: 281 398 7891e-mail: sales@solartr<strong>on</strong>.comwww.solartr<strong>on</strong>usa.coma Roxboro Group Company<str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g> Mobrey GmbH Deutschland tel: 0211/99 808-0<str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g> Mobrey Ltd China tel: 021 6353 5652<str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g> Mobrey sp z o o Polska tel: 022 871 7865<str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g> Mobrey AB Sverige tel: 08-725 01 00<str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g> Mobrey SA France tel: 01.30.17.40.80<str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g> Mobrey SA-NV Belgium tel: 02/465 3879The right is reserved to amend detailsgiven in this publicati<strong>on</strong> without noticeIP7105Mar 2003

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!