Solartron on-line Viscometers - Measurement Resources
Solartron on-line Viscometers - Measurement Resources
Solartron on-line Viscometers - Measurement Resources
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Covimat 105-DC rangeApplicati<strong>on</strong>: For high temperatures and pressuresDC40DThe DC40D range is suitable for c<strong>on</strong>tinuousmeasurement of viscosity at high temperatures and highpressures. To prevent heat losses - and to avoidcrystallisati<strong>on</strong> and hardening processes at lowthroughputs or at high temperatures - the DC40D cellshave an isothermal (jacketed) wall. A range of flangeopti<strong>on</strong>s is available and for direct measurement or theproduct temperature, a thermowell is provided for atemperature sensor.DC40EThe DC40E range is designed for c<strong>on</strong>tinuousmeasurement of viscosity at low pressures and hightemperatures. A thermowell is provided to accept atemperature sensor for direct measurement of theproduct temperature. There is a range of flangeopti<strong>on</strong>s.Specificati<strong>on</strong>sViscosity rangeAchievable accuracyMax. temp. of productMax. pressureMax. flow rateMaterial of measuring cellMaterial of sealApprox. weight of cell +adapter (depends <strong>on</strong> flange)*Twin gap measuring cellsCovimat DC40E250ºC (482ºF)25 bar (362 psig)or to flange rating9.5 kg (20.95 lb)1 to 720,000cP± 1% FS40 l/min (10.57 USgall/min)316L stainless steelAsbestos freeCovimat DC40D300ºC (572ºF)170 bar (2,465 psig)or to flange rating18 kg (39.69 lb)Viscosity ranges (via interchangeable cylinders)Covimat DC40E Covimat DC40DDia. (mm)DS*5957513524Standard (cP)1 to 1909 to 92020 to 2,00060 to 6,000240 to 24,000720 to 72,000with Z opti<strong>on</strong> (cP)10 to 1,90090 to 9,200200 to 20,000600 to 60,0002,400 to 240,0007,200 to 720,00044mm (1.73in)44mm (1.73in)195mm(7.68in)210mm(8.27in)138mm(5.43in)145mm(5.71in)
Covimat 105 Ordering MatrixCovimat <strong>Measurement</strong> Head4-20mA output for DD Flow CellsDescripti<strong>on</strong>Order No.ATEX approved 81051CTSignal C<strong>on</strong>verters (opti<strong>on</strong>al)TypeOrder No.7950 wall (Klipp<strong>on</strong>) 7950 AA7951 panel (Klipp<strong>on</strong>) 7951 AA7951 panel (D-Type) 7951 AB Covimat <strong>Measurement</strong> Head4-20mA output for TO & DC flow cellsDescripti<strong>on</strong> Order No.ATEX approved81051ATATEX approved (Z versi<strong>on</strong>) 81051BTCoupling piece 00112810PT100 Temp. Sensor(opti<strong>on</strong>al) 81053748ACovimat TO Immersi<strong>on</strong> SystemImmersi<strong>on</strong> length Order No.200mm (7.87in) 00112812300mm (11.81in) 00112813500mm (19.68in) 00112814Covimat DC40D Flow BeakersDescripti<strong>on</strong> Order No.DN25 PN100 RTJ 81053AAA1½” ANSI 150 RF 81053AAB1½” ANSI 600 RF 81053AAC1½” ANSI 900 RF 81053AADDN32 PN40 RF 81053AAEDN25 PN100 RF 81053AAFCovimat DD Flow CellDescripti<strong>on</strong> Order No.Measuring cell(excl. cylinder/bob) 00112405Covimat DC40E Flow BeakersDescripti<strong>on</strong> Order No.2” ANSI 150 RF 81053BABDN50 PN40 RF 81053BAE2” TRI CLAMP 81053BAG2” IDF 81053BAHCylinders/bobsRangeOrder No.1 - 460 cP * 001124435 - 1,350 cP * 0011244410 - 3,100 cP * 0011244515 - 5,000 cP 0011244630 - 8,800 cP * 0011244740 - 11,200 cP 0011244850 - 13,200 cP 00112449* Twin gap measuring cellsCylinders/bobsSize Order No.69.5mm 0011235068mm 0011234963mm 0011234846mm 0011234731mm 00112273Cylinders/bobsSize Order No.24mm 0011230935mm 0011230751mm 0011230557mm 0011230359mm 00112302Double-split 00112242
Installati<strong>on</strong> accessoriesCorrect installati<strong>on</strong> is a key factor in the quest foraccurate l<strong>on</strong>g-term measurement, particularly whereviscosity is used as a critical c<strong>on</strong>trol parameter andwhere <strong>line</strong> values must be referred to base c<strong>on</strong>diti<strong>on</strong>s.Flow through chambers are available with 1” or 2” NBinlet/outlet tubes, with a choice of weld ends,compressi<strong>on</strong> fittings or flanges, and an opti<strong>on</strong>al thermaljacket.The flow through chamber is designed for installati<strong>on</strong> asa local fast loop (slipstream) <strong>on</strong> a main pipe<strong>line</strong>, andgives the following advantages:• minimizes the need for <strong>on</strong>-site calibrati<strong>on</strong>• improves accuracy• enhances viscosity referrals• increases tolerance of solids and entrained gas• reduces maintenanceFor direct pipe<strong>line</strong> fitting and improved thermalperformance, <str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g>’s range of prepared collars(weldolets) are available for pipe diameters of 4”, 6”, 8”or 10” nominal bore.See data sheet B782703 for more detailsMore details of <str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g> transducers, signal c<strong>on</strong>verters and flow computers are given in the following brochures:Density transducersGas Density and Specific Gravity Products795x Series Signal C<strong>on</strong>verters795x Series Flow Computers for the gas industry795x Series Flow Computers for oil and refined productsInstallati<strong>on</strong> accessoriesIP7003B1253B1251B1248B1249B782703<str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g> Mobrey Limited158 Edinburgh Avenue SloughBerks UK SL1 4UETel: 01753 756600Fax: 01753 823589e-mail: sales@solartr<strong>on</strong>.comwww.solartr<strong>on</strong>mobrey.com<str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g> Mobrey19408 Park Row, Suite 320,Houst<strong>on</strong> TX 77084 USATel: 281 398 7890Fax: 281 398 7891e-mail: sales@solartr<strong>on</strong>.comwww.solartr<strong>on</strong>usa.coma Roxboro Group Company<str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g> Mobrey GmbH Deutschland tel: 0211/99 808-0<str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g> Mobrey Ltd China tel: 021 6353 5652<str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g> Mobrey sp z o o Polska tel: 022 871 7865<str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g> Mobrey AB Sverige tel: 08-725 01 00<str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g> Mobrey SA France tel: 01.30.17.40.80<str<strong>on</strong>g>Solartr<strong>on</strong></str<strong>on</strong>g> Mobrey SA-NV Belgium tel: 02/465 3879The right is reserved to amend detailsgiven in this publicati<strong>on</strong> without noticeIP7105Mar 2003