12.07.2015 Views

Download - Vacuumschmelze

Download - Vacuumschmelze

Download - Vacuumschmelze

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Item no.Type T60404-N…Rated currentIPN, rms@K N = 1 : NMax. measuring rangeIPmax. @ V C = + 5 V or V C = ± 15 VTurns ratioK NOutput variableV ref -input/output 2Ambient temperature rangeT ambSupply voltageV CCreepage/clearanceSystem/working voltageacc. to EN 61800-5-1(reinforced insul.; insul. mat.group 1; PD 2; OV 3)Frequency rangefAccuracyX @ IPN; T amb = 25 °CMechanical outline[A]4646- 50X460 2 25174646- 100X461 2 504646-X3004646-X4004646-X4104646-X4124646-X4133325128652510850201510035251003525[A]±150±75±50±200±100±66±85±43±28±21±17±130±65±43±128±64±43±175±82±58±208±104±691:14002:14003:14001:11002:11003:11001:10002:10003:10004:10005:10001:10002:10003:10001:10002:10003:10001:20002:20003:20001:15002:15003:1500[° C]-40 to[V] [mm] [V][kHz]DC toV 5 yes + 85 + 5 10.2/10.2 600/1020 100 0.7 4V 5 yes + 85 + 5 10.2/10.2 600/1020 100 0.7 4I + 85I + 85I + 85I + 85I + 85+ 12... 15+ 12... 15+ 12... 15+ 12... 15+ 12... 15[%]10.2/10.2 600/1020 200 0.5 510.2/10.2 600/1020 200 0.5 610.2/10.2 600/1020 200 0.5 710.2/10.2 600/1020 200 0.5 710.2/10.2 600/1020 200 0.5 71Reflow-solderable versions (“Paste-to-Pin”) of these types are available. Please enquire.2Reference voltage output 2.5 ± 0.005 V. Ri = 670 Ohm. Can be overwritten and therefore used as an input for an external reference. Voltage range 0 ... 4 V.3Types without reference voltage input/output (V ref – pin): For new developments we recommend the use of the types of 4646-X66x or 4646-X76x with referencevoltage input/output to achieve higher measuring accuracy.4The rated current for these types is only a reference value. They all can be used up to the maximum ambient temperature, loaded with the following rms valuesper primary turn: 17 A in parallel connection, 12 A in series connection. Within these limits, the sensor type can be selected according to the measuring range.5V A = V ref ± (0.625 * I P /I PN ), resp. V A = 2.5 V ± (0.625 * I P /I PN ).Examples, type 4646-X761: Primary current (peak) = 85 A. Output voltage range (peak) = 2.5 V ± (0.625 * 85 A/25 A) = 0.375 V ... 4.625 VPrimary current (RMS) = 20 A. Output voltage range (RMS) = 0.625 * 20 A/25 A = 0.5 V rmsActive current sensors for maximum accuracy7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!