12.07.2015 Views

1o2 Valve Brochure - ICU Medical, Inc.

1o2 Valve Brochure - ICU Medical, Inc.

1o2 Valve Brochure - ICU Medical, Inc.

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

A needlefree drug deliverysystem to help you meetyour clinical needs.1 ° 2 ®Fluid Delivery SystemA safe and simple needlefree drug deliverysystem designed for fast high volume fluidadministration without the risk of obstruction.


Clave 1 ° 2 ® ®Needlefree Fluid Delivery Connector SystemThe 1 ° 2 valve is the first technology to provide automatic checkvalve security that allows the intravenousadministration and aspiration of fluid with the simple push of a button. The revolutionary buttoneliminates turn handles and provides a low profile streamlined design.Provides the highest flow rate availablethrough the main line, equal to nine Frenchor more than 600 mL/min at gravity. Thissame valve has the smallest availabledeadspace; less than 0.025 mL of residualfluid which, allows for very precise drugdelivery.The valve sideport port allows forintermittent drug delivery with the securityof a one-way check valve. This pressureactivated one-way valve protects thesystem from accidental infusion, or themixing of incompatible drugs and fluids ona manifold. Propofol, Lipids and Bloodproducts can safely be administeredthrough the 1 ₀ 2 valve.By simply pushing the button of the 1 ₀ 2, itconverts to a two-way valve that permitsaspiration. When the button is released, the1 ₀ 2 valve automatically returns to theclosed one-way position. The sideportaspiration feature is useful to prime the 1 ₀ 2,dilute a drug, draw a flush syringe, orconduct a blood draw.Features:> > One way or two way valve capabilities.> > Ideal for anesthesia, trauma, intensivecare and cardiac applications wherehigh volumes must be administeredquickly and without obstructions orturbulence.> > Greater than 9 French flow.> > The check valve prevents theaccidental mixing of drugs while onthe manifold.> > Allows for precise drug delivery.> > Minimizes drug waste.> > Multi-gang capability savesset up time.Performance SpecificationsTest Product Performance Requirement *Fluid Flow Through Main Line Averaged > 632 cc/min at 36” head height gravity flowSideport Crack Pressure3.3 psig averageHigh Pressure Resealability≥ 60 psigNegative Pressure Resealability ≥ -9.5 psigCompatibilityLipid and Blood Products Compatible* <strong>ICU</strong> <strong>Medical</strong>, <strong>Inc</strong>. Special Evaluation 05-120T; June, 2005©2012 <strong>ICU</strong> <strong>Medical</strong>, <strong>Inc</strong>. | M1-1060 Rev. 02800.824.7890 | www.icumed.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!