12.07.2015 Views

Function List

Function List

Function List

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Function</strong> <strong>List</strong>A Group: Standard functions<strong>Function</strong> Code Name RangePID ControlPID ControlAVR functionAutomatic EnergySavingOperation mode andacc./dec. functionExternal freq. tuningFrequencycaluculationA061A261A062A262A063A064A065A066A067A068A071A072A073A074A075A076A077A078A081A082A085A086A092A292A093A293A094A294A095A295A096A296A097A098A101A102A103A104A105A141A142A143A145A146A151A152A153A154A155Frequency upper limit settingFrequency upper limit setting, 2nd motorFrequency lower limit settingFrequency lower limit setting, 2nd motorJump (center) frequency setting 1Jump (hysteresis) frequency setting 1Jump (center) frequency setting 2Jump (hysteresis) frequency setting 2Jump (center) frequency setting 3Jump (hysteresis) frequency setting 3PID EnablePID EnablePID proportional gainPID integral time constantPID derivative time constantPV scale conversionPV source settingReverse PID actionPID output limitAVR function selectAVR voltage selectOperation mode selectionEnergy saving mode tuningAcceleration (2) time settingAcceleration (2) time setting, 2nd motorDeceleration (2) time settingDeceleration (2) time setting, 2nd motorSelect method to switch to Acc2/Dec2 profileSelect method to switch to Acc2/Dec2 profile, 2nd motorAcc1 to Acc2 frequency transition pointAcc1 to Acc2 frequency transition point, 2nd motorDec1 to Dec2 frequency transition pointDec1 to Dec2 frequency transition point, 2nd motorAcceleration curve selectionDeceleration curve selection[OI]-[L] input active range start frequency[OI]-[L] input active range end frequency[OI]-[L] input active range start current[OI]-[L] input active range end current[OI]-[L] input start frequency enableA input select for calculate functionB input select for calculate functionCalculation symbolADD frequencyADD direction selectPot. input active range start frequencyPot. input active range end frequencyPot. input active range start currentPot. input active range end currentPot.input start frequency enable0.0/Freq. lower limit setting to maximum freq.0.0/Freq. lower limit setting (2nd) to maximum freq. (2nd)0.0/Start freq. to freq. upper limit setting0.0/Start freq. (2nd) to freq. upper limit setting (2nd)0.0 to 400.0.0 to 10.00.0 to 400.0.0 to 10.00.0 to 400.0.0 to 10.000(Disable)/01(Enable)0.2 to 5.00.0 to 150.00.00 to 100.00.01 to 99.9900([OI] terminal)/01([O] terminal)/02(RS485)/10(Calculation result)00(OFF)/01(ON)0.0 to 100.000(Enable)/01(Disable)/02(Enabled except during deceleration)200V class: 200/215/220/230/240400V class: 380/400/415/440/460/48000(Normal)/01(Energy-saver)0.0 to 100.00.01 to 99.99/100.0 to 999.9/1000. to 3000.0.01 to 99.99/100.0 to 999.9/1000. to 3000.0.01 to 99.99/100.0 to 999.9/1000. to 3000.0.01 to 99.99/100.0 to 999.9/1000. to 3000.00(2CH from input terminal)/01(transition freq.)00(2CH from input terminal)/01(transition freq.)0.0 to 400.00.0 to 400.00.0 to 400.00.0 to 400.000(Linear)/01(S-curve)00(Linear)/01(S-curve)0.0 to 400.00.0 to 400.00. to 100.0. to 100.00(Use setting value)/01(0Hz)00(Digital operator)/01(Keypad potentiometer)02(O input)/03(OI input)/04(RS485)00(A141+A142)/01(A141-A142)/02(A141*A142)0.0 to 400.000(Plus)/01(Minus)0.0 to 400.00.0 to 400.00.0 to 100.00.0 to 100.000(Use offect (A151 value))/01(Use 0Hz)Default-EF(CE) -U(UL) -R(JP)0.00.00.00.00.00.50.00.50.00.5001.01.00.001.0000000.000200/4000050.015.0015.0015.0015.0000000.00.00.00.000000.00.00.100.010102000.0000.00.00.0100.010.00.00.00.00.00.50.00.50.00.5001.01.00.001.0000000.000200/400 200/4000050.015.0015.0015.0015.0000000.00.00.00.000000.00.00.100.010102000.0000.00.00.0100.010.00.00.00.00.00.50.00.50.00.5001.01.00.001.0000000.0020050.015.0015.0015.0015.0000000.00.00.00.000000.00.00.100.010102000.0000.00.00.0100.01: Allowed[ X: Not allowed ]UnitHzHzHzHzHzHzHzHzHzHz--secsec---%-V-%secsecsecsec--HzHzHzHz--HzHz%%----Hz-HzHz%%-Run modeeditLo HiXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXb Group: Fine-tuning functions<strong>Function</strong> Code Name RangeRestart afterinstantaneous powerfailureOverload restrictionb001b002b003b004b005b011b012b212b013b213b021b221b022b222b023b223b028b228b029b030Selection of automatic restart modeAllowable under-voltage power failure timeRetry wait time before motor restartInstantaneous power failure / under-voltage tripalarm enableNumber of restarts on power failure / undervoltagetrip eventsStart frequency to be used in case of frequencypull-in restartElectronic thermal settingElectronic thermal setting, 2nd motorElectronic thermal characteristicElectronic thermal characteristic, 2nd motorOverload restriction operation modeOverload restriction operation mode, 2nd motorOverload restriction settingOverload restriction setting, 2nd motorDeceleration rate at overload restrictionDeceleration rate at overload restriction, 2nd motorOverload restriction source selectionOverload restriction source selection, 2nd motorDeceleration rate of frequency pull-in restartCurrent level of frequency pull-in restartLock b031 Software lock mode selection00(Alarm output)/01(Restart at 0Hz)/02(Resume after freq. matching)/03(Resume freq. matching then trip)0.3 to 25.00.3 to 100.000(Disable)/01(Enable)00(Restart 16 times)/01(Always restart)00(frequency at previous shutoff)/01(Max. Hz)/02(Set frequency)0.2*Rated current to 1.0*Rated current00(Reduced torque)/01(Constant torque)/02(Reduced torque 2)00(Disable)/01(Enable)/02(Enable for during acceleration)0.2*Rated current to 1.5*Rated current0.1 to 3000.000(b022/b222 setting level)/01([O]-[L] analog input)0.1 to 3000.00.2*Rated current to 2.0*Rated current00([SFT] input blocks all edits)/01([SFT] input blocks edits exceptF001 and Multispeed parameters/02(No access to edits)/03(Noaccess to edits except F001 and Multi-speed parameters)/10(Highlevelaccess,including b031)Default-EF(CE) -U(UL) -R(JP)001.01.0000000001.01.000000001010101000001 01 0101 01 011.5*Rated current1.01.000000.5Rated currentRated current30.030.000000.5Rated current01 01001.01.00000001.01.000000.5: Allowed[ X: Not allowed ]Unit-secsec---AA----AAsecsec--secARun modeeditLo HiXXXXXXXXXXXXXXXXXXXX01 - XXXX8

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!