13.07.2015 Views

HIGH AND LOW BAY INDUCTION LIGHTING

HIGH AND LOW BAY INDUCTION LIGHTING

HIGH AND LOW BAY INDUCTION LIGHTING

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>HIGH</strong> <strong>AND</strong> <strong>LOW</strong> <strong>BAY</strong> <strong>INDUCTION</strong> <strong>LIGHTING</strong>ENERGY


<strong>HIGH</strong> <strong>AND</strong> <strong>LOW</strong> <strong>BAY</strong> <strong>INDUCTION</strong> <strong>LIGHTING</strong>Louvered Industrial Fluorescent<strong>INDUCTION</strong> TECHNOLOGYSimkar’s new high/low bay luminaires with InductionTechnology are the culmination of extensive developmentand testing. We have been able to attain higher ambienttemperatures for our offerings to ensure reliable operationand longevity. Induction is ideal for applications in whichinstant on, high color rendition (CRI), long life, andenergy savings are desired. Since the average inductionlamp life is 100,000 hours versus 10,000 - 20,000hours for HID, maintenance and work interruptions aredramatically reduced. All the advantages of inductioncoupled with possible rebates make Simkar inductionfixtures a winner.IP Series acrylic prismatic reflectorSeries Mounting Lamp Wattage Voltage LensIPS = 16”IPM = 22”IPL = 25”1 = Hook and Slide box2 = Hook/Slide box, 6’ Cord, and twist+lock PlugFor IPS08 = 80W10 = 100WFor IPM10 = 100W15 = 150W20 = 200WFor IPL20 = 200W25 = 250W30 = 300WFor Hook Only Mounting, selectU = Universal (120V-277V 50/60Hz)For Hook, Cord, & Plug Mounting,and/or Fusing, specify line voltage1 = 120V2 = 277V3 = 208V4 = 240V5 = 480VFor IPS and IPMBlank = No lensL = Enclosed, Flat Acrylic LensD = Enclosed, Drop Acrylic Prismatic Lens AssemblyK = Enclosed, Conical Acrylic Lens AssemblyFor IPLBlank = No lensK = Enclosed, Conical Acrylic Lens AssemblyA = Enclosed, Conical Acrylic Prismatic Aislelighter Lens AssemblyOptionsF = Single Fuse for 120V/ 277V (specify line voltage in “Voltage” field)J = Dual Fuses for 208V/240V (specify line voltage in “Voltage” field)OS(X)¹ = PIR Occupancy Sensor (Damp Location):(X) specify sensor type:Blank = Standard unit down to 14°F (-10°C)C = Cold, down to -22°F (-30°C)OS-D(X)¹ = PIR Occupancy and Daylight Photo Cell Sensors(Damp Location):(X) specify sensor type:Blank = Single RelayD = Dual RelayDC = Dual Relay, Cold, down to -22°F (-30°C)AccessoriesSC-6 = Ballast/Reflector 6’ Safety ChainSP-18 = Swivel Pendant Mount ¾” x 18” (other lengths available upon request)822FWG = Wire Guard Cage for complete optics assemblies (all models)For IPS816DLA = Enclosed, Drop Acrylic Prismatic Lens Assembly816DG-R = Wire Guard for 16” IPS reflector without lensFor IPM822DLA-HR = Enclosed, Drop Acrylic Prismatic Lens Assembly816CLA = Enclosed, Conical Acrylic Lens Assembly822CLA-HR = Enclosed, Conical Acrylic Lens Assembly822WG = Wire Guard for 22” IPM reflector without lensEB22WG = Snap-on Wire Guard for 22” IPM reflector without lensFor IPM825A-CLA = Enclosed, Conical Acrylic AisleLighter Prismatic Lens Assembly8225G-R = Wire Guard for 25” IPL reflector without lens1All Occupancy Sensors are pre-wired with an adjustable fixture mounting bracket and are provided with 3 interchangeable lenses. Contact factory for dimming, wattages, and availability.IP SeriesIS Series spun reflectorSeries Mounting Lamp Wattage Voltage LensISR = 16”ISL = 22”1 = Hook and Slide box2 = Hook/Slide box, 6’ Cord, and twist+lock PlugFor ISR08 = 80W10 = 100WFor ISL10 = 100W15 = 150W20 = 200WFor Hook Only Mounting, selectU = Universal (120V-277V 50/60Hz)For Hook, Cord, & Plug Mounting, and/orFusing, specify line voltage1 = 120V2 = 277V3 = 208V4 = 240V5 = 480VBlank = No lensL = Enclosed, Flat Acrylic LensD = Enclosed, Drop Acrylic Prismatic Lens AssemblyK = Enclosed, Conical Acrylic Lens AssemblyOptionsF = Single Fuse for 120V/ 277V (specify line voltage in “Voltage” field)J = Dual Fuses for 208V/240V (specify line voltage in “Voltage” field)OS(X)¹ = PIR Occupancy Sensor (Damp Location):(X) specify sensor type:Blank = Standard unit down to 14°F (-10°C)C = Cold, down to -22°F (-30°C)OS-D(X)¹ = PIR Occupancy and Daylight Photo Cell Sensors(Damp Location):(X) specify sensor type:Blank = Single RelayD = Dual RelayDC = Dual Relay, Cold, down to -22°F (-30°C)AccessoriesSC-6 = Ballast/Reflector 6’ Safety ChainSP-18 = Swivel Pendant Mount ¾” x 18” (other lengths available upon request)822FWG = Wire Guard Cage for complete optics assemblies (all models)For ISREB16CLA = Conical Acrylic Prismatic Lens assemblyEB16DLA = Drop Acrylic Prismatic Lens assemblyEB16DG = Wire Guard for Flat Glass LensEB16WG = Wire Guard without LensFor ISLEB22DG = Wire Guard for Flat Glass LensEB22DG = Wire Guard for Flat Acrylic LensEB22WG = Wire Guard Snaps on ISL reflector with or without Lens AssembliesEB22DG-R = Wire Guard without LensIS Series1All Occupancy Sensors are pre-wired with an adjustable fixture mounting bracket and are provided with 3 interchangeable lenses. Contact factory for dimming, wattages, and availability.For additional configurations, contact factory800 523-3602 • www.simkar.com


Latitude Louvered Industrial Fluorescent<strong>HIGH</strong> <strong>AND</strong> <strong>LOW</strong> <strong>BAY</strong> <strong>INDUCTION</strong> <strong>LIGHTING</strong>Features and benefitsDedicated Induction System Ballast housing and lamp mounting systems aredesigned specifically for induction and are optimized for reliability andperformance.Optics Four reflector systems are available in our Induction Series:Acrylic Prismatic Reflector, Spun Aluminum Reflector, Faceted AluminumReflector, and White Painted Spun Aluminum Reflector.Superior Thermal Management Designed for an elevated ambient ensuresreliable operation and long life.Amalgam Lamp Technology Light output is not adversely affected bytemperature extremes and produces high lumen output over a broadrange with a 100,000 hour life.Occupancy Sensing (Optional) Individual PIR (passive infrared) and Daylightoptions allow the fixture to be turned off for additional energy savings.Induction lighting is an instant-on technology even in cold environments.IF Series faceted aluminum reflectorSeries Mounting Lamp Wattage Voltage LensIFS = 17”IFL = 22”1 = Hook and slide box2 = Hook/Slide box, 6’ Cord, and twist+lock PlugFor IFS08 = 80W10 = 100WFor IFL10 = 100W15 = 150W20 = 200WFor Hook Only Mounting, selectU = Universal (120V-277V 50/60Hz)For Hook, Cord, & Plug Mounting, and/orFusing, specify line voltage1 = 120V2 = 277V3 = 208V4 = 240V5 = 480VBlank = No lensL = Enclosed, Flat Glass LensOptionsF = Single Fuse for 120V/ 277V (specify line voltage in “Voltage” field)J = Dual Fuses for 208V/240V (specify line voltage in “Voltage” field)OS(X)¹ = PIR Occupancy Sensor (Damp Location):(X) specify sensor type:Blank = Standard unit down to 14°F (-10°C)C = Cold, down to -22°F (-30°C)OS-D(X)¹ = PIR Occupancy and Daylight Photo Cell Sensors(Damp Location):(X) specify sensor type:Blank = Single RelayD = Dual RelayDC = Dual Relay, Cold, down to -22°F (-30°C)AccessoriesFor IFS onlySDC17LA = 17” Wire Guard for Flat Glass AssemblySDC17DG = 17” Pre-assembled Wire Guard and Flat Glass AssemblySDC17WG = 17” Wire Guard without lensFor IFS and IFLSP-18 = Swivel Pendant Mount ¾” x 18” (other lengths available upon request)SC-6 = Ballast/Reflector 6’ Safety Chain822FWG = Wire Guard Cage for complete optics assembliesFor IFL onlyEB22WG = Snap-on Wire GuardSDC22LA = Wire Guard pre-assembled with Flat Glass Lens1All Occupancy Sensors are pre-wired with an adjustable fixture mounting bracket and are provided with 3 interchangeable lenses. Contact factory for dimming, wattages, and availability.IF SeriesILB 30” low baySeries Mounting Lamp Wattage VoltageILB1 = Hook and slide box2 = Hook/Slide box, 6’ Cord, and twist+lock Plug10 = 100W15 = 150W20 = 200W25 = 250W30 = 300WFor Hook Only Mounting, selectU = Universal (120V-277V 50/60Hz)For Hook, Cord, & Plug Mounting, and/orFusing, specify line voltage1 = 120V2 = 277V3 = 208V4 = 240V5 = 480VOptionsF = Single Fuse for 120V/ 277V (specify line voltage in “Voltage” field)J = Dual Fuses for 208V/240V (specify line voltage in “Voltage” field)OS(X)¹ = PIR Occupancy Sensor (Damp Location):(X) specify sensor type:Blank = Standard unit down to 14°F (-10°C)C = Cold, down to -22°F (-30°C)OS-D(X)¹ = PIR Occupancy and Daylight Photo Cell Sensors(Damp Location):(X) specify sensor type:Blank = Single RelayD = Dual RelayDC = Dual Relay, Cold, down to -22°F (-30°C)AccessoriesSC-6 = Ballast/Reflector 6’ Safety ChainSP-18 = Swivel Pendant Mount: ¾” x 18” (other lengths available upon request)1All Occupancy Sensors are pre-wired with an adjustable fixture mounting bracket and are provided with 3 interchangeable lenses. Contact factory for dimming, wattages, and availability.ILBDrop lens includedFor additional configurations, contact factory800 523-3602 • www.simkar.com


<strong>HIGH</strong> <strong>AND</strong> <strong>LOW</strong> <strong>BAY</strong> <strong>INDUCTION</strong> <strong>LIGHTING</strong>DimensionsIP SeriesIPSIPMIPL19.75”11”22.23” 100W23” 150/200W13.60”23.2” 200W23.8” 250/300W13.80”16.25” 22.20”25.20”IS SeriesISRISL20.75”22.43” 100W23.24” 150/200W12.13”13.80”16.61”22.40”IF SeriesIFSIFL20.75”21.06” 80/100W21.88” 150/200W12”12.50”17.25”22.75”ILB23.13” 100W23.94” 150/200W24.50” 250/300WENERGYLook for this logo – it designates products andservices that provide energy-saving alternativesand are designed to help reduce your costs11.25”3.25”30”All components are UL ListedUL Certification Pending700 Ramona Avenue • Philadelphia, Pennsylvania 19120 • 800 523-3602 • www.simkar.com01102013

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!