Time Delay AdjustmentThe Relay Output Time Delay function is adjustable from 1-99seconds. Use a small screwdriver to turn the rotary switchesS2 and S3 for the desired time delay interval. Switch S2adjusts for single seconds, and switch S3 adjusts for tens.Example: A time delay of 14 seconds wouldrequire S3 to be set at 1 and S2 to be set at 4.Probe Status SwitchWith the probe status switch in the “A” position, the relay isenergized, and the green “SAFE” lamp is lit when the probeis tilted. With the probe status switch in the “B” position,the relay is energized and the green “SAFE” lamp is litwhen the probe is in a vertical position.Standard Probe ConnectionsAll tilt switch probes should be connected to terminals TB2-2 and TB2-3.Alternate Sensor ConnectionsSensor Power TB2-1Sensor Signal TB2-2Sensor Ground TB2-3Specifications • <strong>SCU</strong>-<strong>200</strong> Control UnitInput Power ...................................... 115 Vac ± 10% 50/60 Hz.Opt. 230 Vac, 12/24 VdcProbe Signal Voltage ................ +12 Vdc (10 kΩ pull-up to+12 Vdc)Auxiliary SensorSupply Voltage................................ +12 Vdc @ 17 mA maxRelay Output .................................... DPDT Form C relay,rated 5 Amp @ 250 Vacresistive load.Relay Status ...................................... Switch SelectableRelay Status Lamps.................... 2 replaceable lamps, 28 VacWiring Connections.................... Screw barrier terminal14 AWG maxEnclosure ............................................ NEMA 12, 6 x 4 x 3 inchNEMA 4 optionalOperating Temperature .......... 0°C to +70° CStorage Temperature................ -20°C to + 70°COption ....................................................Intrinsically safe availableProbes <strong>MTS</strong>-<strong>20H</strong> <strong>MTS</strong>-<strong>30H</strong>Contact Rating (all) 1.7 Amp max. @ 250 Vac SPSTContact Type Mercury MercuryProbe Actuation Angle 15° ± 5° 15° ± 5°Weight 18 oz. 75 oz.Cable 8 ft., 18 gauge 8 ft., 18 gauge2 conductor 2 conductorNeoprene NeopreneEnclosure Steel SteelWARNINGCONTAINS MERCURYDISPOSE ACCORDING TO LOCAL, STATE AND FEDERAL LAWS<strong>MTS</strong> Tilt Switches & <strong>SCU</strong> Control UnitWiring Diagram}}Dimensions •<strong>SCU</strong>-<strong>200</strong> Control UnitStandard <strong>MTS</strong>-<strong>20H</strong> Tilt Switch with HangerHeavy-Duty <strong>MTS</strong>-<strong>30H</strong> Tilt Switch with HangerThreadsize1/2” NPT!Threadsize1/2” NPT!Specifications subject to change without notice.ES-160 Rev D6111 Blue Circle DriveMinnetonka, MN 55343Phone: 952-930-0100Fax: 952-930-0130ISO9001:<strong>200</strong>0 CertifiedFree Catalog and Application Assistance1-800-328-6170Visit Us Online:www.electro-sensors.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!