<strong>Product</strong> <strong>data</strong> <strong>sheet</strong><strong>3RH2140</strong>-<strong>2AP00</strong>CONTACTOR RELAY, 4NO AC 230V, 50/60 HZ,SZ S00, SPRING-LOADED TERMINALGeneral technical <strong>data</strong>:<strong>Product</strong> brand name<strong>Product</strong> designationSize of the contactorProtection class IP / frontal/front sideSIRIUScontactor relayS00IP20Degree of pollution 3Insulation voltage / with degree of pollution 3 / rated value V 690Installation altitude / at a height over sea level / maximum m 2000Ambient temperature• during transport °C -55 … 80• during storage °C -55 … 80• during the operating phase °C -25 … 60Resistance against shock10g / 5 ms and 5g / 10 msImpulse voltage resistance / rated value kV 6Item designation• according to DIN 40719 extendable after IEC 204-2 / accordingto IEC 750• according to DIN EN 61346-2KKMechanical operating cycles as operating time• of the contactor / typical 30000000<strong>3RH2140</strong>-<strong>2AP00</strong>Page 1/ 610/09/2010subject to modifications© Copyright Siemens AG 2010


• of the contactor with added auxiliary switch block / typical 10000000• of the contactor with added electronics-compatible auxiliaryswitch block / typical10000000Control circuit:Type of voltage / of the controlled supply voltageACControl supply voltage frequency• 1 / rated value Hz 50• 2 / rated value Hz 60Control supply voltage / 1• at 50 Hz / for AC / rated value V 230• at 60 Hz / for AC / rated value V 230Operating range factor control supply voltage rated value / ofsolenoid• at 50 Hz / for AC 0.8 … 1.1• at 60 Hz / for AC 0.85 … 1.1Apparent pull-in power / of the solenoid / for AC V·A 37Apparent holding power / of the solenoid / for AC V·A 5.7Inductive power factor• with the pull-in power of the coil 0.8• with the pull-in power of the coil 0.25Auxiliary circuit:<strong>Product</strong> extension / auxiliary switchIdentification number and letter for switching elementsContact reliability / of the auxiliary contactsYes40 E1 faulty switching per 100 million (17 V, 1 mA)Number of NC contacts / for auxiliary contact 0• instantaneous switching 0• delayed switching 0• asynchronous switching 0• lagging switching 0Number of NO contacts / for auxiliary contact 4• instantaneous switching 4• delayed switching 0• asynchronous switching 0• leading switching 0Number of changeover contacts• for auxiliary contact 0Operating current / of the auxiliary contacts• at AC-12 / maximum A 10• at AC-15<strong>3RH2140</strong>-<strong>2AP00</strong>Page 2/ 610/09/2010subject to modifications© Copyright Siemens AG 2010


• at 230 V A 10• at 400 V A 3• at 500 V A 2• at 690 V A 1• with 1 current path• at DC-12• at 24 V A 6• at 110 V A 3• at 220 V A 1• at DC-13• at 24 V A 6• at 110 V A 1• at 220 V A 0.3Short-circuit:Design of the fuse link / for short-circuit protection of theauxiliary switch• requiredFuse gL/gG: 10 A, miniature circuit breaker C 6 A(short-circuit current Ik < 400 A)Installation/mounting/dimensions:Built in orientationType of mountingverticalscrew and snap-on mounting onto 35 mm standardmounting railWidth mm 45Height mm 60Depth mm 73Distance, to be maintained, to the ranks assembly• forwards mm 0• backwards mm 0• upwards mm 0• downwards mm 0• sidewards mm 0Distance, to be maintained, to earthed part• forwards mm 6• backwards mm 0• upwards mm 6• downwards mm 6• sidewards mm 6Distance, to be maintained, conductive elements• forwards mm 0• backwards mm 0<strong>3RH2140</strong>-<strong>2AP00</strong>Page 3/ 610/09/2010subject to modifications© Copyright Siemens AG 2010


• upwards mm 0• downwards mm 0• sidewards mm 0Connections:Design of the electrical connection• for auxiliary and control current circuitspring-loaded terminalsType of connectable conductor cross section• for auxiliary contact• solid2x (0.5 ... 4 mm2)• stranded wire• with wire end processing• without conductor final cutting2x (0.5 ... 2.5 mm2)2x (0.5 ... 2.5 mm2)• for AWG conductors / for auxiliary contacts 2x (20 ... 12)Certificates/approvals:Verification of suitabilityCE / UL / CSA / CCCSafety:B10 value / with high demand rate• according to SN 31920 1000000Proportion of dangerous failures• with low demand rate / according to SN 31920 % 40• with high demand rate / according to SN 31920 % 75Failure rate (FIT value) / with low demand rate• according to SN 31920 FIT 100T1 value / for proof test interval or service life• according to IEC 61508 a 10Protection against electrical shockfinger-safeFurther information:Information- and Downloadcenter (Catalogs, Brochures,…)http://www.siemens.com/industrial-controls/catalogsIndustry Mall (Online ordering system)http://www.siemens.com/industrial-controls/mallCAx-Online-Generatorhttp://www.siemens.com/caxService&Support (Manuals, Certificates, Characteristics, FAQs,...)http://support.automation.siemens.com/WW/view/en/<strong>3RH2140</strong>-<strong>2AP00</strong>/allImage <strong>data</strong>base (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=<strong>3RH2140</strong>-<strong>2AP00</strong><strong>3RH2140</strong>-<strong>2AP00</strong>Page 4/ 610/09/2010subject to modifications© Copyright Siemens AG 2010


<strong>3RH2140</strong>-<strong>2AP00</strong>Page 5/ 610/09/2010subject to modifications© Copyright Siemens AG 2010


last change: Sep 20, 2010<strong>3RH2140</strong>-<strong>2AP00</strong>Page 6/ 610/09/2010subject to modifications© Copyright Siemens AG 2010