<strong>Product</strong> <strong>data</strong> <strong>sheet</strong><strong>3TK2823</strong>-<strong>2CB30</strong>SIRIUS SAFETY RELAY WITH RELAY RELEASECIRCUITS (RC),AC/DC 24V, 22.5MM,SPRING-LOADED TERMINAL,RC INSTANT.: 2S, RC DELAYED: 0S,MC: 0NC, MONITORED START, BASIC DEVICE,MAX. ACHIEVABLE SIL: 3, PL: EGeneral technical details:<strong>Product</strong> brand name<strong>Product</strong> designationDesign of the productProtection class IP / of the housingProtection class IP / of the terminalProtection against electrical shockSIRIUSsafety relaysfor EMERGENCY-STOP unitsIP40IP20finger-safeInsulation voltage / rated value V 300Ambient temperature• during storage °C -40 … 80• during the operating phase °C -25 … 60Air pressure• according to SN 31205 kPa 90 … 106Relative humidity• during the operating phase % 10 … 95Installation altitude / at a height over sea level / maximum m 2,000Resistance against vibration / according to IEC 60068-2-6Resistance against shock5 ... 500 Hz: 0,075 mm8g / 10 msImpulse voltage resistance / rated value V 4,000EMC emitted interference EN 60947-5-1Item designation• according to DIN 40719 extendable after IEC 204-2 / accordingto IEC 750• according to DIN EN 61346-2KTFNumber of sensor inputs• 2-channel 1Design of the cascadingType of the safety-related wiring / of the inputs<strong>Product</strong> feature / transverse contact-secureno<strong>net</strong>wo-channelYes<strong>3TK2823</strong>-<strong>2CB30</strong>Page 1/ 509/14/2010subject to modifications© Copyright Siemens AG 2010


Safety Integrity Level (SIL) / according to IEC 61508SIL3SIL claim limit (for a subsystem) / according to EN 62061 3Performance level (PL) / according to ISO 13849-1eCategory / according to EN 954-1 4Category / according to ISO 13849-1 4Probability of dangerous failure per hour (PFHD) / with highdemand rate / according to EN 62061Average probability of failure on demand (PFDavg) / with lowdemand rate / according to IEC 61508T1 value / for proof test interval or service life / according to IEC615081/h 0.13E-81/h 0.12E-5a 20Number of outputs / as contact-affected switching element• as NC contact / for reporting function / instantaneous switching 0• as NO contact / fail-safe / instantaneous switching 2• as NO contact / fail-safe / delayed switching 0Number of outputs / as contact-less semiconductor switchingelement• fail-safe• delayed switching 0• non-delayed 0• for reporting function• delayed switching 0• non-delayed 0Stop category / according to DIN EN 60204-1 0General technical details:Design of the input• cascading-entrance/operation-even switching• reducing-entrance• start-up entranceDesign of the electrical connection / jumper socketNoYesYesYesOperating cycles / maximum 1/h 1,000Switching capacity current / of the NO contacts of the relayoutputs• at DC-13• at 24 V A 5• at 115 V A 0.2• at 230 V A 0.1• at AC-15• at 115 V A 5• at 230 V A 5<strong>3TK2823</strong>-<strong>2CB30</strong>Page 2/ 509/14/2010subject to modifications© Copyright Siemens AG 2010


Thermal current / of the contact-affected switching element /maximumA 5Electrical operating cycles as operating time / typical 100,000Mechanical operating cycles as operating time / typical 10,000,000Design of the fuse link / for short-circuit protection of the NOcontacts of the relay outputs / necessarygL/gG: 6 A, or quick: 10 AResistance to direct current / of the cable / maximum Ω 30Cable length / between sensor and electronic evaluation device/ with Cu 1.5 mm² and 150 nF/km / maximumm 1,000Make time / with monitored start• maximum ms 30Backslide delay time / after opening of the safety circuits /typicalms 20Backslide delay time / at mains power cut• maximum ms 150Recovery time / after opening of the safety circuits / typical ms 400Recovery time / after mains power cut / typical s 600Pulse duration• of the sensor input / minimum ms 25• of the ON pushbutton input / minimum s 0.025Control circuit:Type of voltage / of the controlled supply voltageAC/DCControl supply voltage frequency• 1 / rated value Hz 50• 2 / rated value Hz 60Control supply voltage / 1 / for DC / rated value V 24Control supply voltage / 1 / at 50 Hz / for AC / rated value V 24Control supply voltage / 1 / at 60 Hz / for AC / rated value V 24Operating range factor control supply voltage rated value / ofsolenoid• at 50 Hz• for AC 0.85 … 1.1• at 60 Hz• for AC 0.85 … 1.1• for DC 0.85 … 1.2Installation/mounting/dimensions:Built in orientationType of mountinganyscrew and snap-on mountingWidth mm 22.5Height mm 120<strong>3TK2823</strong>-<strong>2CB30</strong>Page 3/ 509/14/2010subject to modifications© Copyright Siemens AG 2010


Depth mm 120Connections:Design of the electrical connectionspring-loaded terminalsType of connectable conductor cross section• solid2x (0.25 ... 1.5 mm2)• finely stranded• with wire end processing• without wire end processing2x (0,25 ... 1 mm2)2x (0.25 ... 1.5 mm2)<strong>Product</strong> Function:<strong>Product</strong> function• light barrier monitoring• standstill monitoring• protective door monitoring• automatic start• mag<strong>net</strong>ic switch monitoring Normally closed contact-Normallyopen contact• rotation speed monitoring• laser scanner monitoring• monitored start-up• light grid monitoring• mag<strong>net</strong>ic switch monitoring Normally closed contact-Normallyclosed contact• emergency-OFF function• step mat monitoringSuitability for interaction / pressing controlNoNoNoNoNoNoNoYesNoNoYesYesNoAcceptability for application• safety cut-out switch• position switch monitoring• EMERGENCY-OFF circuit monitoring• opto-electronical protection device monitoring• monitoring of mag<strong>net</strong>ically operated switches• monitoring of proximity switches• safety-oriented circuitsYesYesYesNoNoNoYesCertificates/approvals:Verification of suitability• TÜV (German technical inspectorate) certificate• UL-registration• BG BIA certificateBG, SUVA, UL, CSA, EN 60204-1, EN ISO 12100, EN954-1, IEC 61508YesYesYes<strong>3TK2823</strong>-<strong>2CB30</strong>Page 4/ 509/14/2010subject to modifications© Copyright Siemens AG 2010


Further information:Information- and Downloadcenter (Catalogs, Brochures,…)http://www.siemens.com/industrial-controls/catalogsGlobal Industry Mall (Online ordering system)http://www.siemens.com/industrial-controls/mallService&Support (Manuals, Certificates, Characteristics, FAQs,...)http://support.automation.siemens.com/WW/view/en/<strong>3TK2823</strong>-<strong>2CB30</strong>/allImage <strong>data</strong>base (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=<strong>3TK2823</strong>-<strong>2CB30</strong>last change: Sep 6, 2010<strong>3TK2823</strong>-<strong>2CB30</strong>Page 5/ 509/14/2010subject to modifications© Copyright Siemens AG 2010