13.07.2015 Views

Manual - Simply Scuba

Manual - Simply Scuba

Manual - Simply Scuba

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SECOND STAGES39in order not to jeopardize the correct operation of the regulator.Cressi-sub assumes no responsibility for any operationcarried out by personnel not authorized by Cressi-sub.The 2nd stage is connected to one of the 3/8” LP outlets of the1st stage through an intermediate pressure, high flow capacityhose.Cressi-sub Ellipse is a downstream regulator design.This means that in the event of over-pressurization of the 1ststage, excess air will be safely released through the 2nd stage.Cressi-sub Ellipse complies with 89/686/CEE Directive of21/12/1989, having been tested and certified by Genova-basedTest Board No. 0474 RINA, through tests complying with UNI EN250:2000 standard which sets forth the requirements concerning3rd-class Individual Safety Devices (DPI), and consequentlybears the EC marking followed by the Certification Board identification(0474) in compliance with Art. 11B DE 89/686/CEE.2.2 - Ellipse disassembly and maintenancefig. 10The Ellipse regulator has been designed to ensure easy andquick servicing by authorized repair technicians. WARNING: The 2nd stage must ONLY be opened, disassembledand calibrated at Cressi-sub authorized centres andthe calibration values can NOT be and must NOT be changedUsing the same socket wrench supplied with the regulator todisassemble the first stage HP and LP little plugs, you can openand disassemble the 2nd stage, reaching directly its internalmechanical components. This extraordinary characteristic,which is unique in this field and patented, allows to open the tankin a very easy and quick way in order to clean it, and to check forthe perfect operation of the various components.In the different steps shown on the previous figures, the cap andthe middle compartment of the exhaust conveyor appear asmechanically constrained to each other. The unusual (patented)“cam-lock” locking system, allows to open and close the tankvery quickly, locking both the cap and the diaphragm with highefficiency and accuracy.Opening and closing a regulator has never been so easy, and sosafe, too!!!In order to make test, overhaul and setup easier, all the mechanicalcomponents of the second stage can be fully removed fromthe tank in a few seconds, without changing its calibration. In thisway, during the periodic maintenance works, any worn part canbe disassembled and replaced after all the mechanical componentsof the regulator have been removed, thus allowingextraordinary easy operations.To remove the mechanical components from the tank, asshown on the following figure, just loose the lateral lock nut andremove the two cone-shaped locking pins. The mechanicalcomponents can then be removed as a whole, i.e. without havingto remove any single component, and especially withoutchanging the regulator calibration: a unique characteristic in thisfield which provides numerous advantages.ENGLISH

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!