13.07.2015 Views

ANCHOR BOLTS - masco.net

ANCHOR BOLTS - masco.net

ANCHOR BOLTS - masco.net

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

[ PREVIOUS ] [ NEXT ]REGLETPOUR IN PLACEM A S C O . N E TTYPE CO - ConcreteDescription: Reglet and Counter flashing system (2-piece,spring-action type). Available in copper, stainless steel,aluminum and galvanized steel.Application: CAST-IN-PLACE CONCRETE. Notrecommended for tilt-up construction (requires specialprovision to insure proper alignment between concretepanels).Special Features: Factory-provided removable foam insertprotects slot from obstruction during concrete pours.No. Size Wt/Pc (lbs) Lf/CtnFRY CO-G 26 ga. galv. x 10' 2.0 250FRY FLASH-G 26 ga. galv. x 10' 1.7 250FACE OF CONCRETETYPE "CO" REGLETCOUNTER FLASHING("SPINGLOK")BASE FLASHINGROOF MEMBRANECANT5⅛"7" MINNOTE:1. LAP ADJACENTLENGTHS OF COUNTERFLASHING 3"FACE OF WALL/PARAPETFLANGE (SEE SPECIAL FEATURES)TYPE "MA" REGLETCOUNTERFLASHING("SPRINGLOK")BASE FLASHINGROOF MEMBRANECANT5½"7" MINNOTE:1. LAP ADJACENT LENGTHSOF REGLET 1".2. LAP ADJACENT LENGTHSOF COUNTER FLASHING 3".TYPE MA - MasonryDescription: Reglet and counter flashing system (2-piece spring-action type). Reglet with 1-1/2" flange andcounter flashing are available in copper, stainless steel,aluminum and galvanized steel. Reglet with 4" flange isavailable in copper, stainless steel and steel.Application: BRICK or CONCRETE MASONRY UNIT (CMU).Special Features: Reglet is available with 1-1/2"horizontal flange (Reglet Type MA-1.5) for brick and 4"horizontal flange (Reglet Type MA-4) for CMU.No. Size Wt/Pc (lbs) Lf/CtnFRY MA-G 1-1/2"x24 ga. galv. x 10' 2.7 250FRY FLASH-G 26 ga. galv. x10' 1.7 250TYPE SM - Surface MountDescription: Reglet and counter flashing system (2-piece, spring-action type). Available in copper,stainless steel, aluminum, and galvanized steel.Application: SURFACE MOUNT (pre-cast concrete,tilt-up concrete and retrofit applications overconcrete, brick, and CMU). Requires sealant (silicon orpolyurethane).Special Features: Reglet supplied with neoprene-facedstainless steel washer for proper fastening.No. Size Wt/Pc (lbs) Lf/CtnFRY SM-G 24 ga. galv. x 10' 2.0 250FRY FLASH-G 26 ga. galv. x 10' 1.7 2502½"FACE OF WALL/PARAPETSEALANT (SILICONE/POLYURETHANE/POLYVINYL SULFIDE)FASTENER (INSTALL W/ FACTORY-SUPPLIED NEOPRENE BACKEDSTAINLESS STEEL WASHER)TYPE "SM" REGLETCOUNTER FLASHING("SPRINGLOK")BASE FLASHINGROOF MEMBRANECANT5¼"7" MINNOTE:1. LAP ADJACENT LENGTHS OFREGLET 1".2. LAP ADJACENT LENGTHS OFCOUNTER FLASHING 3".3. FASTENER:A. CONCRETE SUBSTRATE ONLY: 1"DRIVE PIN.B. CONCRETE, BRICK OR CMUSUBSTRATE: RAWL LITE SPIKE.C. METAL OR WOODFRAMING: 8X1" TEK SCREW.204MASONS SUPPLY COMPANYOregon (800) 537-3407 ♦ Washington (800) 537-6216[ BACK TO MASCO.NET ]Clackamas | Eugene | West Eugene | Gresham | Hillsboro | Medford | Portland | Salem | Seattle | Tacoma | Wilsonville | Woodinville | Vancouver

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!