13.07.2015 Views

MSDS - McGean

MSDS - McGean

MSDS - McGean

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>McGean</strong>-Rohco, Inc.2910 Harvard AvenueCleveland, Ohio 44105-3010 USAPhone: 216-441-4900 Fax: 216-441-1377www.mcgean.comMATERIAL SAFETY DATA SHEET23204© 2014 <strong>McGean</strong>-Rohco, Inc. PAGE 1 OF 4PRODUCT NAME: CEE-BEE E-2002A <strong>MSDS</strong> No.: 23204REVISION: 5PREPARED BY: DIR ENV AFFAIRS ISSUE DATE:04/11/95 EFFECTIVE DATE: 06/20/13--------------------------------------------------------------------------------SECTION A. MATERIAL IDENTIFICATION.MANUFACTURER: McGEAN-ROHCO, INC.CHEMTREC:TELEPHONE #: 800-424-930038521 SCHOOLCRAFT AVE. OR 703-527-3887LIVONIA MI 48150TELEPHONE: 216-441-4900--------------------------------------------------------------------------------SECTION B. INGREDIENTS AND HAZARDS.INGREDIENT: BENZYL ALCOHOL30.0 - 35.0%CAS NUMBER: 100-51-6EXPOSURE LIMIT: TWA: NONE ESTABLISHEDSUSPECT CARCINOGEN: NO--------------------------------------------------------------------------------SECTION C. PHYSICAL DATA.APPEARANCE: OPAQUE,LIGHT BLUE LIQUIDBOILING POINT: 100CODOR: AMMONIA (


<strong>McGean</strong>-Rohco, Inc.2910 Harvard AvenueCleveland, Ohio 44105-3010 USAPhone: 216-441-4900 Fax: 216-441-1377www.mcgean.comMATERIAL SAFETY DATA SHEET23204© 2014 <strong>McGean</strong>-Rohco, Inc. PAGE 2 OF 4UNUSUAL FIRE OR NONE.EXPLOSION HAZARDS:--------------------------------------------------------------------------------SECTION E. REACTIVITY DATAMATERIAL IS STABLE.HAZARDOUS POLYMERIZATION WILL NOT OCCUR.CONDITIONS TOAVOID:INCOMPATIBILITYMATERIALS TO AVOID:NASTRONG OXIDIZERS OR STRONG MINERAL ACIDS.HAZARDOUS DECOMPOSITION OXIDES OF CARBON.PRODUCTS:--------------------------------------------------------------------------------SECTION F. HEALTH HAZARD DATA.SUMMARY OF RISKS:MEDICAL CONDITIONSWHICH MAY BEAGGRAVATED BY CONTACT:TARGET ORGANS:SARA-ACUTESKIN DISORDERSSKIN,EYES,RESPIRATORY SYSTEM.PRIMARY ENTRY ROUTES: THROUGH CONTACT AND INHALATION OF VAPORS.ACUTE EFFECTS:IRRITATION OF SKIN OR EYES.CHRONIC EFFECTS:NONE KNOWN.SIGNS & SYMPTOMS OF OVEREXPOSURE:EYE CONTACT: SEVERE IRRITATION,REDNESS,TEARING,BLURRED VISION.SKIN CONTACT: CAN CAUSE IRRITATION.INHALATION:INGESTION:NASAL AND RESPIRATORY IRRITATION,CNS EFFECTS,NAUSEA,HEADACHE.GASTROINTESTINAL IRRITATION,NAUSEA,VOMITING,DIARRHEA.


<strong>McGean</strong>-Rohco, Inc.2910 Harvard AvenueCleveland, Ohio 44105-3010 USAPhone: 216-441-4900 Fax: 216-441-1377www.mcgean.comMATERIAL SAFETY DATA SHEET23204© 2014 <strong>McGean</strong>-Rohco, Inc. PAGE 3 OF 4EMERGENCY & FIRST AID PROCEDURES:EYE CONTACT: FLUSH WITH WATER FOR 15 MINUTES. GET MEDICAL ATTENTION.SKIN CONTACT: WASH WITH SOAP AND WATER.INHALATION: REMOVE TO FRESH AIR. IF BREATHING IS DIFFICULT, ADMINISTEROXYGEN. GET MEDICAL ATTENTION.INGESTION: IF CONSCIOUS,GIVE SEVERAL GLASSES OF WATER. DO NOT INDUCEVOMITING. GET MEDICAL ATTENTION.--------------------------------------------------------------------------------SECTION G. SPILL, LEAK AND DISPOSAL PROCEDURES.SPILL/LEAK ABSORB ON VERMICULITE OR OTHER SUITABLE MATERIAL AND PLACEPROCEDURES: IN A CLOSED CONTAINER.WASTEMANAGEMENT& DISPOSALPROCEDURES:INCINERATE OR SEND TO AN EPA APPROVED WASTE DISPOSALFACILITY.FOLLOW ALL LOCAL,STATE AND FEDERAL REGULATIONS.RCRA # (IF DISPOSED AS RECEIVED): NONE--------------------------------------------------------------------------------SECTION H. SPECIAL PROTECTION INFORMATIONPERSONAL PROTECTIVE EQUIPMENT:GOGGLES: CHEMICAL GOGGLES.GLOVES: CHEMICALLY RESISTANT APRON, BOOTS AND GLOVES RECOMMENDED.RESPIRATOR: IF VENTILATION IS NOT ADEQUATE OR IF TWA IS EXCEEDED USENIOSH OR MSHA APPROVED RESPIRATOR.OTHER: SUFFICIENT TO PREVENT SKIN CONTACT.WORKPLACE CONSIDERATIONS:VENTILATION: SUFFICIENT TO PREVENT ADVERSE EFFECTS.SAFETY STATIONS: EYE WASH.OTHER:SAFETY SHOWER.--------------------------------------------------------------------------------SECTION I. SPECIAL PRECAUTIONS


<strong>McGean</strong>-Rohco, Inc.2910 Harvard AvenueCleveland, Ohio 44105-3010 USAPhone: 216-441-4900 Fax: 216-441-1377www.mcgean.comMATERIAL SAFETY DATA SHEET23204© 2014 <strong>McGean</strong>-Rohco, Inc. PAGE 4 OF 4SPECIAL HANDLING& STORAGE PROCEDURES:STORE IN A COOL,DRY AREA.D.O.T. CLASS NONE UN REGISTER: NONEIMDG CLASS: NONE UN REGISTER: NONEIATA CLASS: NONE UN REGISTER: NONE--------------------------------------------------------------------------------EXPLANATION OF SYMBOLSNA = NOT APPLICABLEUK = UNKNOWN--------------------------------------------------------------------------------THIS MATERIAL SAFETY DATA SHEET IS OFFERED SOLELY FOR YOUR INFORMATION,CONSIDERATION, AND INVESTIGATION. WHILE THE INFORMATION AND RECOMMENDATIONSSET FORTH HEREIN ARE BELIEVED TO BE ACCURATE AS OF THE DATE HEREOF,McGEAN-ROHCO, INC. MAKES NO WARRANTY WITH RESPECT THERETO AND DISCLAIMS ALLLIABILITY FROM RELIANCE THEREON.THIS MATERIAL SAFETY DATA SHEET HAS BEEN PREPARED TO COMPLY WITHTITLE 29 CODE OF FEDERAL REGULATIONS, PART 1910.1200, OSHA HAZARDCOMMUNICATION STANDARD, AND TO FULFILL THE ANNUAL CHEMICAL NOTIFICATIONREQUIREMENTS OF SARA TITLE III, SECTION 313.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!