13.07.2015 Views

MSDS - McGean

MSDS - McGean

MSDS - McGean

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>McGean</strong>-Rohco, Inc.2910 Harvard AvenueCleveland, Ohio 44105-3010 USAPhone: 216-441-4900 Fax: 216-441-1377www.mcgean.comMATERIAL SAFETY DATA SHEET20138© 2012 <strong>McGean</strong>-Rohco, Inc. PAGE 1 OF 4PRODUCT NAME: CEE-BEE INTEX 8992 [CASE] <strong>MSDS</strong> No.: 20138REVISION: 1PREPARED BY: DIR ENV AFFAIRS ISSUE DATE:04/25/05 EFFECTIVE DATE: 02/02/12--------------------------------------------------------------------------------SECTION A. MATERIAL IDENTIFICATION.MANUFACTURER: McGEAN-ROHCO, INC.CHEMTREC:TELEPHONE #: 800-424-930038521 SCHOOLCRAFT AVE. OR 703-527-3887LIVONIA MI 48150TELEPHONE: 734-464-2220--------------------------------------------------------------------------------SECTION B. INGREDIENTS AND HAZARDS.INGREDIENT: PROPYLENE GLYCOL T-BUTYLETHER1.0 - 5.0%CAS NUMBER: 5131-66-8EXPOSURE LIMIT: TWA: NOT ESTABLISSHEDSUSPECT CARCINOGEN: NO--------------------------------------------------------------------------------SECTION C. PHYSICAL DATA.APPEARANCE: CLEAR BLUE THIN LIQUIDBOILING POINT: 100CODOR: LEMON PLEASANTFREEZING POINT: NASPECIFIC GRAVITY: 0.99 - 1.01VAPOR PRESSURE: >1 MMHG @ 20 CpH: 10.0 - 11.0VAPOR DENSITY: 0.7 (AIR=1)% VOLATILE BY VOLUME: NONEEVAPORATION RATE:


<strong>McGean</strong>-Rohco, Inc.2910 Harvard AvenueCleveland, Ohio 44105-3010 USAPhone: 216-441-4900 Fax: 216-441-1377www.mcgean.comMATERIAL SAFETY DATA SHEET20138© 2012 <strong>McGean</strong>-Rohco, Inc. PAGE 2 OF 4UNUSUAL FIRE OR ALTHOUGH THIS PRODUCT HAS A FLASH POINT BELOW 200 F, ITEXPLOSION HAZARDS: WILL NOT SUSTAIN COMBUSTION.--------------------------------------------------------------------------------SECTION E. REACTIVITY DATAMATERIAL IS STABLE.HAZARDOUS POLYMERIZATION WILL NOT OCCUR.CONDITIONS TOAVOID:INCOMPATIBILITYMATERIALS TO AVOID:NONE KNOWNSTRONG OXIDIZING AGENTS.HAZARDOUS DECOMPOSITION OXIDES OF NITROGEN AND CARBON.PRODUCTS:--------------------------------------------------------------------------------SECTION F. HEALTH HAZARD DATA.SUMMARY OF RISKS:MEDICAL CONDITIONSWHICH MAY BEAGGRAVATED BY CONTACT:TARGET ORGANS:IRRITATIONSKIN DISORDERSNONE KNOWNPRIMARY ENTRY ROUTES: EYE, SKIN, INHALATION, INGESTION.ACUTE EFFECTS:MAY CAUSE IRRITATIONCHRONIC EFFECTS:NONE EXPECTED.SIGNS & SYMPTOMS OF OVEREXPOSURE:EYE CONTACT: IRRITATION REDNESS.SKIN CONTACT: IRRITATION.INHALATION:INGESTION:NONE KNOWNNONE KNOWN.


<strong>McGean</strong>-Rohco, Inc.2910 Harvard AvenueCleveland, Ohio 44105-3010 USAPhone: 216-441-4900 Fax: 216-441-1377www.mcgean.comMATERIAL SAFETY DATA SHEET20138© 2012 <strong>McGean</strong>-Rohco, Inc. PAGE 3 OF 4EMERGENCY & FIRST AID PROCEDURES:EYE CONTACT: FLUSH WITH WATER FOR 15 MINUTES. GET MEDICAL ATTENTION.SKIN CONTACT: WASH WITH SOAP AND WATER.INHALATION: REMOVE TO FRESH AIR. IF BREATHING IS DIFFICULT, ADMINISTEROXYGEN. GET MEDICAL ATTENTION.INGESTION: IF CONSCIOUS,GIVE SEVERAL GLASSES OF WATER. DO NOT INDUCEVOMITING. GET MEDICAL ATTENTION.--------------------------------------------------------------------------------SECTION G. SPILL, LEAK AND DISPOSAL PROCEDURES.SPILL/LEAK ABSORB ON VERMICULITE OR OTHER SUITABLE MATERIAL AND PLACEPROCEDURES: IN A CLOSED CONTAINER.WASTEMANAGEMENT& DISPOSALPROCEDURES:INCINERATE OR SEND TO AN EPA APPROVED WASTE DISPOSALFACILITY.FOLLOW ALL LOCAL,STATE AND FEDERAL REGULATIONS.RCRA # (IF DISPOSED AS RECEIVED): NONE--------------------------------------------------------------------------------SECTION H. SPECIAL PROTECTION INFORMATIONPERSONAL PROTECTIVE EQUIPMENT:GOGGLES: NOT NORMALLY REQUIREDGLOVES: NOT NORMALLY REQUIREDRESPIRATOR: NOT REQUIRED REQUIREDOTHER:NONEWORKPLACE CONSIDERATIONS:VENTILATION: AS NEEDEDSAFETY STATIONS: NAOTHER:NA--------------------------------------------------------------------------------SECTION I. SPECIAL PRECAUTIONS


<strong>McGean</strong>-Rohco, Inc.2910 Harvard AvenueCleveland, Ohio 44105-3010 USAPhone: 216-441-4900 Fax: 216-441-1377www.mcgean.comMATERIAL SAFETY DATA SHEET20138© 2012 <strong>McGean</strong>-Rohco, Inc. PAGE 4 OF 4SPECIAL HANDLING& STORAGE PROCEDURES:STORE IN A COOL,DRY AREA.D.O.T. CLASS COMBUSTIBLE(>119GAL) UN REGISTER: NA-1993IMDG CLASS: NONE UN REGISTER: NONEIATA CLASS: NONE UN REGISTER: NONE--------------------------------------------------------------------------------EXPLANATION OF SYMBOLSNA = NOT APPLICABLEUK = UNKNOWN--------------------------------------------------------------------------------THIS MATERIAL SAFETY DATA SHEET IS OFFERED SOLELY FOR YOUR INFORMATION,CONSIDERATION, AND INVESTIGATION. WHILE THE INFORMATION AND RECOMMENDATIONSSET FORTH HEREIN ARE BELIEVED TO BE ACCURATE AS OF THE DATE HEREOF,McGEAN-ROHCO, INC. MAKES NO WARRANTY WITH RESPECT THERETO AND DISCLAIMS ALLLIABILITY FROM RELIANCE THEREON.THIS MATERIAL SAFETY DATA SHEET HAS BEEN PREPARED TO COMPLY WITHTITLE 29 CODE OF FEDERAL REGULATIONS, PART 1910.1200, OSHA HAZARDCOMMUNICATION STANDARD, AND TO FULFILL THE ANNUAL CHEMICAL NOTIFICATIONREQUIREMENTS OF SARA TITLE III, SECTION 313.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!