13.07.2015 Views

BIOPAC MRI catalog

BIOPAC MRI catalog

BIOPAC MRI catalog

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Noninvasive Blood Pressure - Wireless Monitoring SystemSetup: HLT100C interface module + NIBP-<strong>MRI</strong>The NIBP-<strong>MRI</strong> provides real-time, beat-to-beat pressuremeasurement values during magnetic resonance imaging. Thesystem tracks systolic and diastolic blood pressure (using Pulse-Decomposition Analysis technology). The device analyzes thetiming and amplitudes of the primary left ventricular ejectionpulse as well as the arterial pulse reflections, at the thumb, middlephalange of the middle finger, at the wrist, or on the upper arm.PulsePulse - Photo PlethysmographSetup: MEC<strong>MRI</strong>-TRANS + PPG100C-<strong>MRI</strong> amp + TSD200-<strong>MRI</strong> transducerThe TSD200-<strong>MRI</strong> transducer is sensitive to Blood Volume Pulse (BVP) via photo-plethysmographicmethods. Use it to record the blood volume pulse pressure waveform. It’s primarilydesigned for finger or toe attachment, but can be taped to other body locations with TAPE1.Pulse - Pressure PadSetup: DA100Camp + AFT30-XL tubing (included) throughwave guide + TSD110-<strong>MRI</strong> transducerThe TSD110-<strong>MRI</strong> consists of a differential pressure transducer,sensor, and tubing. Use it to record pulse and pulse rate—itrequires no electrical connections between <strong>MRI</strong> control andchamber rooms and works on a number of body locations.Affix to finger or major pulse point with TAPE1.Oxygen SaturationNIBP-<strong>MRI</strong> dataElectrodermal ActivitySetup: MEC<strong>MRI</strong>-TRANS + EDA100C-<strong>MRI</strong> amplifier + lead/electrodesRecord EDA inside the <strong>MRI</strong>. Use AcqKnowledge software filters to improve the quality of theEDA signal, if required, and provide automated analysis.Electrodes•Disposable: For excellent EDA responses, <strong>BIOPAC</strong> recommendsEL509 dry disposable electrodes with GEL101 andLEAD108 (1.8 m), LEAD108A (3.6 m),LEAD108B (15 cm), or LEAD108C (30 cm).•Reusable: Disposable electrodes are recommended, but reusableEDA dataTSD203 electrodes will also work for skin conductance.Pulse dataSetup: OXY-<strong>MRI</strong> New! Use as stand alone system or connect to MP SystemSpO2 amplifier with fiber-optic finger sensor for adult human pulse oximetry.Pulse Rate Range: 18–321 BPM, Saturation Accuracy (Arms): 70–100% ± 2 digits.Includes isolation adapter and cables to connect to an existing HLT100C forMP Systems. Additional finger sensors available: OXY-<strong>MRI</strong>-SENSOR.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!