PRESS RELEASE3/25/08Contact: Maggie Reed Lutz(315) 797-1310magree@ecrinternational.comFOR IMMEDIATE RELEASEUtica Boilers is pleased to announce the release of the industry leading TriFire 3-pass oil-firedboiler. Installation of the TriFire is made easy with its simple wiring, small footprint and pipingmanifold tree for quick installation of standard features and controls. The TriFire is compactand strong with a maximum allowable working pressure of 65 psi. Wide flue ways, a flexible oilline, dual hinged swing door with left or right mount option, site glass and sampling port makeservicing easy. TriFire’s low mass design is eco-friendly too, with all models being Energy Starrated, AFUE ratings as high as 86.5% and low standby losses.Utica Boilers is a brand of ECR International. With facilities in Utica, Dunkirk, Rome NY, andWallaceburg ON, ECR International is a leading manufacturer of high efficiency heating and airconditioning appliances for the North American market.###Utica Boilers • 2201 Dwyer Ave. • P.O. Box 4729 • Utica, New York 13504-4729Ph: 315/797-1310 • Main Fax: 315/797-3762 • Customer Service Fax: 315/724-9319 • Marketing Fax: 315/733-1759E-Mail: info@uticaboilers.com • Web: www.uticaboilers.com


Cast Iron Oil-Fired Water BoilersQuality Engineered for Efficiency and DependabilityHigh Efficiency3-Pass BoilerUP TO86.5 %AF•U•E•AnECR International Brand


TriFire SeriesOil-Fired High Efficiency 3-Pass Water BoilersTriFire – the Eco-FriendlyChoice in Oil Boilerswith up to 86.5% AFUE!Advanced High Efficiency3-Pass Heat Exchanger DesignThe TriFire’s multiple flue-way passages maximize surface area,optimizing heat transfer. Standard stainless steel baffles furtherenhance efficiency. A compact low mass design allows the unit torecover from low standby water temperatures utilizing half theenergy of standard 3-pass oil boilers. The overall result – agreener oil boiler through improved technology, ideal for spaceheating and applications utilizing an indirect water heater.Burners, Venting &Packaging OptionsWith a wide range of ENERGY STAR efficient models from.75 to 1.65 GPH, chimney or direct vent*, Beckett, Riello orCarlin Burners* and packaging choices including knockdown– the TriFire is tailored to the needs of your application.*Available later in 2008Compact FootprintWith the leanest design in its class, the TriFire eases into tightapplications while being easier on you. Compact and strong,maximum allowable working pressure of 65 psi.E-A-S-Y InstallationPlug ’n PlayPipingThe TriFire Series features an installer friendly Piping Tree clearlylabeled for simple, efficient installation of standard Aquastat,Pressure/Temperature Gauge and Relief Valve as well as optionalLow Water Cut Off and High Limit Control. Piping connectionsare conveniently located at the back of the unit so the jacket canbe installed after the unit has been piped.WiringThe TriFire features an easily accessible terminal block locatedunder the top protective cover. The unit is factory wired withmolex connections for the Burner, Main Control, High Limitand Low Water Cut Off .WarrantyTriFire features a limited lifetime warranty with 5 and 10 YearComfort Plus Extended Parts and Labor Warranties available.3RDPASS2NDPASS1STPASSPiping Manifold Tree for quick installationof standard features and optional controlsControls come standard with factorywiring and plug ’n play harnessesPlug ’n play connections foroptional High Limit and LWCOPanels can beinstalled or removedafter the pipingis connectedBeckett burner withplug ’n play connector


Removable front panel for easycleaning and serviceFlexible oil lineReversible hinged dooreasily lifts off hingesand positions right or leftWide Flue-Ways for easy cleaningSite Glass & Sample portfor easy serviceHinge MountE-A-S-Y ServiceDealer-Driven Features include:• Flexible oil line combined with an easy accessheat exchanger featuring dual hinge swing doorwith right or left mount option• Wide Flue-Ways for easy cleaning• Site Glass for flame observation• Removable 1/4" sampling port forcombustion readingsTriFire Factory SuppliedStandard Equipment• High Efficiency Cast Iron 3-Pass Heat Exchanger• Powder-Coated Steel Jacket• Lighted On/Off Switch• Reversible Dual Hinged Swing-Out Burner Door• Oil Burner• Target Wall• Liner as Required by Model• Efficiency Baffles by Model• 3/4" ASME Relief Valve• Piping Tree• 1-1/4" Supply & Return Tappings (Qty. 1 ea.)• Temperature/Pressure Gauge• Aquastat/Boiler Control• Circulator Control• Terminal Block for Power Wiring• Wiring Harnesses with Molex Connectors• Burner Electrical Disconnect• Drain ValveReversible swing door forinstallation FlexibilityOptional Equipment• Low Water Cut Off and/or Manual ResetHigh Limit are factory pre-wired and includeplug ’n play molex connector harnesses• Quick Connect Harness• Knock-Down Packaging• Burner Choices*• Direct Vent** Available later in 2008


RATINGS AND CAPACITIESOil-fired High Efficiency 3-Pass Water BoilerMODELNO.NO.OFSEC.INPUT**MBH***HEATINGCAPACITY**MBHNETI=B=RRATING**MBHFIRINGRATECHIMNEY BOILERDIMENSIONS (INCHES)A.F.U.E.SIZE FLUE ††APPROX.SHIP†GPHA B CWEIGHT*UB4TRA075 4 105 90 79 0.75 8" x 8" x 15' 5" 17 3/4 17 3/4 34 1/4 86.0% 436*UB5TRA100 5 140 120 105 1.00 8" x 8" x 15' 5" 20 7/8 17 3/4 34 1/4 86.5% 496*UB6TRA130 6 182 157 136 1.30 8" x 8" x 15' 5" 24 1/8 17 3/4 34 1/4 86.5% 560*UB7TRA165 7 231 198 172 1.65 8" x 8" x 15' 6" 27 1/2 17 3/4 34 1/4 85.8% 620* AS AN ENERGY STAR PARTNER, UTICABOILERS HAS DETERMINED THATTHIS PRODUCT MEETS ENERGY STARGUIDELINES FOR ENERGY EFFICIENCY.** MBH = 1,000 BTU PER HOURBTU = BRITISH THERMAL UNIT*** HEATING CAPACITY BASED ON 13% CO2WITH A -0.02" W.C. DRAFT AT BREECH,AND A #1 SMOKE OR LESS. TESTINGWAS DONE IN ACCORDANCE WITHTHE D.O.E. (DEPARTMENT OF ENERGY)TEST PROCEDURE.† GPH = GALLONS PER HOUR OILAT 140,000 BTU PER GALLON†† A.F.U.E. = ANNUAL FUEL UTILIZATIONEFFICIENCY BASED UPON D.O.E. TESTPROCEDURE.● The ratings marked “Net I=B=R Ratings”indicate the amount of remaining heat input thatcan be used to heat the radiation or terminal units.The Net I=B=R ratings shown are based on anallowance of 1.15 in accordance with the factorsshown in the I=B=R Code as published by theHydronics Institute.● Selection of boiler size should be based upon“Net I=B=R Rating” being equal to or greaterthan the calculated heat loss of the building.● The manufacturer should be consulted beforeselecting a boiler for installations having unusualpiping and pick-up requirements.● These boilers are constructed and hydrostaticallytested for a maximum working pressure of 65 psiin accordance with A.S.M.E. (American Society ofMechanical Engineers) Boiler and Pressure VesselCode Section IV standards for cast iron heatingboilers. They are capacity rated in accordance withthe code of the Hydronics Institute.DIMENSIONAL DIAGRAMBack View Side View Front ViewYOUR ASSURANCE OFQUALITYUtica Boilers products are designed, tested, and assembled to ensurethat you receive the very best in home heating comfort, and value.Each product meets or exceeds all recognized safety, performanceand efficiency standards.Specifications and dimensions aresubject to change without notice.Made in Americaby American Craftsmen.USA Contractor Assistance 800-325-5479AnECR International BrandP.O. Box 4729 • Utica, New York 13504Tel. 315-797-1310 • Fax 866-432-7329Web Site: www.uticaboilers.comE-mail: sales@uticaboilers.comAn ISO 9001-2000 Certified CompanyFor more information on Utica Boilers heatingproducts, contact your local distributor or callUtica Boilers Customer Service Department at1-800-325-5479.Part No: 240007378 4/08