13.07.2015 Views

material safety data sheet - Busch Vacuum Technics

material safety data sheet - Busch Vacuum Technics

material safety data sheet - Busch Vacuum Technics

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Vacuum</strong> Pumps and SystemsMATERIAL SAFETY DATA SHEETSECTION IIIPHYSICAL DATAPHYSICAL STATE AT 25°CliquidINITIAL BOILING POINT: ≥ 420°CPOUR POINT:-48°C minimumDENSITY (g/cm 3 at 15°C): 0,88VAPOR PRESSURE (mm Hg at 20°C):NegligibleVISCOSITY (cSt at 40°C): 67VISCOSITY (cSt at 100°C): 10.4EVAPORATION RATE:NegligibleSOLUBILITY IN WATER:NegligibleAPPEARANCE ET ODOR:Blue to green with hydrocarbon odorSECTION IVFIRE AND EXPLOSION DATAFLASH POINT (COC): ≥ 250°CFLAMMABILITY LIMITS IN AIR:LEL: N/A(% PER VOLUME) UEL: N/AAUTOIGNITION TEMPERATURE (°C):N/AEXTINGUISHING MEDIA: Foam, Dry chemical and CO 2HAZARDOUS COMBUSTION PRODUCTS: Normal combustion products, CO and CO 2 .SPECIAL FIRE FIGHTING PROCEDURES:Do not enter confined fire space without adequate protectiveclothing and an approved positive self-contained breathingapparatus. Use water to cool fire exposed containers.SECTION VREACTIVITY DATASTABILITY:CONDITIONS TO AVOID:PRODUCTS TO AVOID:HAZARDOUS DECOMPOSITION PRODUCTS:POLYMERIZATION:StableAvoid excessive heat, open flames and formation of oilmist.Oxidizing agents, strong acids and bases.N/AWill not occurSECTION VITOXICOLOGICAL PROPERTIESINHALATION:CONTACT WITH EYES:SKIN CONTACT:INGESTION:Prolonged exposure to high vapor concentration of this product can cause headache,dizziness and nausea. Short-term overexposure can cause an irritation to therespiratory passages.Exposure limit to the mist = 5 mg/m 3 (TLV/TWA, ACGIH).May cause eye irritation.This product should not cause skin irritation. Prolonged and repeated contact with thisproduct can cause skin drying, which may result in skin irritation and dermatitis.May cause nausea. Do not induce vomiting.MSDS_R-9068-2006 page 2 of 3


<strong>Vacuum</strong> Pumps and SystemsMATERIAL SAFETY DATA SHEETSECTION VIIPREVENTIVE MEASURESVENTILATION:RESPIRATORY PROTECTION:GLOVES:EYE PROTECTION:OTHER PROTECTION:STORAGE AND HANDLING:SPILL AND LEAK PROCEDURES:WASTE DISPOSAL METHODS:Mechanical ventilation is recommended.If mist present, chemical cartridge respirator is recommended.Resistant gloves (Viton, Nitrile and Neoprene) are recommended whenhandling this <strong>material</strong>.Chemical <strong>safety</strong> goggles are recommended.In confined spaces or where the risk of skin exposure is higher, resistantclothing or apron should be worn.Store in cool, dry, ventilated area, away from heat and ignition sources.Use good personal hygiene. Always keep the container close.Eliminate all ignition sources. Stop leak only if safe to do so. Absorbresidue or small spills with absorbent <strong>material</strong> and remove to non-leakingcontainers for disposal.Consult relevant local authorities. Reclaim or dispose of at a licensedwaste disposal company. Incinerate with approval of appropriate localauthority.SECTION VIIIFIRST AID MEASURESINHALATION:CONTACT WITH EYES:CONTACT WITH SKIN:INGESTION:Remove person to fresh air. See a physician if irritation persists.Flush immediately with water for at least 15 minutes.Wash contaminated skin with mild soap and water. See a physician if irritationpersists.This product has a low toxicity. May cause nausea and have a laxative effect. Do notinduce vomiting. Contact an Anti-Poison Center (1-800-463-5060).SECTION IXPREPARATION DATE OF MSDSRevised on 06 JULY 2006We believe that technical information and recommendations contained herein to be reliable and accurate. However,we provide these <strong>data</strong> without warranty or guarantee of any kind, expressed or implied. We assume no responsibilityfor any loss, damage, or expense, direct or consequential, arising from the use of products described herein.MSDS_R-9068-2006 page 3 of 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!