L-20 MEMBER SELECTION TABLESTable 5.3cColumn Capacity 1,2 (P', P' x , P' y ), Timbers10-inch nominal thickness (9.5 inch dry dressed size), C D= 1.0.Column Capacity (lbs.)Select Structural No. 1 No. 210 x 10 10 x 12 10 x 10 10 x 12 10 x 10 10 x 1210" width 12" width 10" width 12" width 10" width 12" widthColumn (=9.5") (=11.5") (=9.5") (=11.5") (=9.5") (=11.5")Species Length (ft.) P' P'x P'y P' P'x P'y P' P'x P'y2 103,000 125,000 125,000 90,000 109,000 109,000 63,000 76,400 76,3004 102,000 125,000 124,000 89,300 108,000 108,000 62,600 76,000 75,8006 101,000 123,000 122,000 87,900 107,000 106,000 61,800 75,400 74,800Douglas Fir- 8 97,900 121,000 119,000 85,900 106,000 104,000 60,600 74,400 73,300Larch 10 93,900 118,000 114,000 83,000 104,000 100,000 58,900 73,100 71,30012 88,300 114,000 107,000 78,900 101,000 95,500 56,600 71,400 68,50014 81,000 108,000 98,000 73,600 96,700 89,100 53,500 69,100 64,70016 72,500 102,000 87,700 67,100 91,800 81,200 49,700 66,300 60,1002 87,700 106,000 106,000 76,500 92,700 92,600 51,800 62,700 62,7004 86,800 106,000 105,000 75,800 92,100 91,800 51,400 62,400 62,2006 85,200 104,000 103,000 74,600 91,200 90,400 50,800 61,900 61,5008 82,800 102,000 100,000 72,800 89,800 88,100 49,800 61,200 60,300Hem-Fir 10 79,100 99,700 95,800 70,200 87,800 84,900 48,500 60,100 58,70012 74,100 96,000 89,700 66,500 85,100 80,500 46,600 58,800 56,50014 67,600 91,200 81,900 61,700 81,600 74,700 44,200 57,000 53,50016 60,200 85,100 72,800 56,000 77,100 67,800 41,200 54,800 49,9002 85,500 104,000 104,000 74,300 90,000 89,900 47,300 57,300 57,2004 84,800 103,000 103,000 73,700 89,500 89,300 47,000 57,100 56,9006 83,500 102,000 101,000 72,800 88,800 88,100 46,500 56,700 56,300Southern 8 81,500 100,000 98,700 71,300 87,600 86,400 45,800 56,100 55,500Pine 10 78,700 98,300 95,300 69,300 86,100 83,900 44,800 55,400 54,30012 74,800 95,400 90,500 66,500 84,000 80,400 43,500 54,300 52,70014 69,600 91,700 84,300 62,700 81,300 75,900 41,800 53,100 50,60016 63,400 86,900 76,800 58,100 77,800 70,300 39,600 51,500 47,9002 72,000 87,200 87,200 63,000 76,400 76,300 45,000 54,500 54,5004 71,400 86,800 86,500 62,600 76,000 75,800 44,700 54,300 54,1006 70,400 85,900 85,200 61,800 75,400 74,800 44,200 53,900 53,500Spruce- 8 68,800 84,700 83,200 60,600 74,400 73,300 43,400 53,300 52,600Pine-Fir 10 66,500 82,900 80,500 58,900 73,100 71,300 42,300 52,400 51,<strong>2001</strong>2 63,300 80,600 76,600 56,600 71,400 68,500 40,800 51,300 49,40014 59,100 77,500 71,600 53,500 69,100 64,700 38,800 49,800 47,00016 54,000 73,700 65,400 49,700 66,300 60,100 36,300 48,000 44,0001P' x values are based on a column continuously braced against weak axis buckling.2P' y values are based on a column continuously braced against strong axis buckling.AMERICAN WOOD COUNCIL
<strong>ASD</strong> STRUCTURAL LUMBER SUPPLEMENTL-21Table 5.4aBending Member (Joist) Capacity (M', C r M', V', and EI ), StructuralLumber2-inch nominal thickness (1.5 inch dry dressed size), C D= 1.0, C L= 1.0.Select Structural No. 2Size (b x d) M' C rM' V' x 10 6 EI M' C rM' V' x 10 6 EINominal Actual (Single) (Repetitive) (Repetitive)Species (in.) (in.) lb.-in. lb.-in. lbs. lb.-in. 2 lb.-in. lb.-in. lbs. lb.-in. 22 x 4 1.5 x 3.5 6,890 7,920 630 10 4,130 4,750 630 92 x 6 1.5 x 5.5 14,700 17,000 990 40 8,850 10,200 990 33Douglas Fir-Larch 2 x 8 1.5 x 7.25 23,700 27,200 1,310 91 14,200 16,300 1,310 762 x 10 1.5 x 9.25 35,300 40,600 1,670 188 21,200 24,400 1,670 1582 x 12 1.5 x 11.25 47,500 54,600 2,030 338 28,500 32,700 2,030 2852 x 4 1.5 x 3.5 6,430 7,400 525 9 3,900 4,490 525 72 x 6 1.5 x 5.5 13,800 15,900 825 33 8,360 9,610 825 27Hem-Fir 2 x 8 1.5 x 7.25 22,100 25,400 1,090 76 13,400 15,400 1,090 622 x 10 1.5 x 9.25 32,900 37,900 1,390 158 20,000 23,000 1,390 1292 x 12 1.5 x 11.25 44,300 50,900 1,690 285 26,900 30,900 1,690 2312 x 4 1.5 x 3.5 8,730 10,000 613 10 4,590 5,280 613 92 x 6 1.5 x 5.5 19,300 22,200 963 37 9,450 10,900 963 33Southern Pine 2 x 8 1.5 x 7.25 30,200 34,800 1,270 86 15,800 18,100 1,270 762 x 10 1.5 x 9.25 43,900 50,400 1,620 178 22,500 25,800 1,620 1582 x 12 1.5 x 11.25 60,100 69,100 1,970 320 30,800 35,500 1,970 2852 x 4 1.5 x 3.5 5,740 6,600 473 8 4,020 4,620 473 82 x 6 1.5 x 5.5 12,300 14,100 743 31 8,600 9,890 743 29Spruce-Pine-Fir 2 x 8 1.5 x 7.25 19,700 22,700 979 71 13,800 15,900 979 672 x 10 1.5 x 9.25 29,400 33,800 1,250 148 20,600 23,700 1,250 1392 x 12 1.5 x 11.25 39,600 45,500 1,520 267 27,700 31,800 1,520 249Table 5.4bBending Member (Joist) Capacity (M', C r M', V', and EI ), StructuralLumber4-inch nominal thickness (3.5 inch dry dressed size), C D= 1.0, C L= 1.0.5MEMBER SELECTION TABLESSelect Structural No. 2Size (b x d) M' C rM' V' x 10 6 EI M' C rM' V' x 10 6 EINominal Actual (Single) (Repetitive) (Repetitive)Species (in.) (in.) lb.-in. lb.-in. lbs. lb.-in. 2 lb.-in. lb.-in. lbs. lb.-in. 24 x 4 3.5 x 3.5 16,100 18,500 1,470 24 9,650 11,100 1,470 204 x 6 3.5 x 5.5 34,400 39,600 2,310 92 20,600 23,700 2,310 78Douglas Fir-Larch 4 x 8 3.5 x 7.25 59,800 68,800 3,050 211 35,900 41,300 3,050 1784 x 10 3.5 x 9.25 89,800 103,000 3,890 439 53,900 62,000 3,890 3704 x 12 3.5 x 11.25 122,000 140,000 4,730 789 73,100 84,100 4,730 6644 x 4 3.5 x 3.5 15,000 17,300 1,230 20 9,110 10,500 1,230 164 x 6 3.5 x 5.5 32,100 36,900 1,930 78 19,500 22,400 1,930 63Hem-Fir 4 x 8 3.5 x 7.25 55,800 64,200 2,540 178 33,900 39,000 2,540 1444 x 10 3.5 x 9.25 83,900 96,400 3,240 369 50,900 58,500 3,240 3004 x 12 3.5 x 11.25 114,000 131,000 3,940 664 69,000 79,400 3,940 5404 x 4 3.5 x 3.5 20,400 23,400 1,430 23 10,700 12,300 1,430 204 x 6 3.5 x 5.5 45,000 51,700 2,250 87 22,100 25,400 2,250 78Southern Pine 4 x 8 3.5 x 7.25 77,600 89,200 2,960 200 40,500 46,600 2,960 1784 x 10 3.5 x 9.25 113,000 129,000 3,780 416 57,600 66,300 3,780 3694 x 12 3.5 x 11.25 154,000 177,000 4,590 748 79,200 91,100 4,590 6644 x 4 3.5 x 3.5 13,400 15,400 1,100 19 9,380 10,800 1,100 184 x 6 3.5 x 5.5 28,700 33,000 1,730 73 20,100 23,100 1,730 68Spruce-Pine-Fir 4 x 8 3.5 x 7.25 49,800 57,300 2,280 167 34,900 40,100 2,280 1564 x 10 3.5 x 9.25 74,900 86,100 2,910 346 52,400 60,300 2,910 3234 x 12 3.5 x 11.25 102,000 117,000 3,540 623 71,100 81,700 3,540 581AMERICAN FOREST & PAPER ASSOCIATION
- Page 1 and 2: SUPPLEMENTStructural LumberASDALLOW
- Page 3 and 4: SUPPLEMENTStructural LumberASDALLOW
- Page 5 and 6: ASD WOOD STRUCTURAL FRAME CONSTRUCT
- Page 7 and 8: ASD STRUCTURAL LUMBER SUPPLEMENTL-1
- Page 9 and 10: ASD STRUCTURAL LUMBER SUPPLEMENTL-3
- Page 11 and 12: ASD STRUCTURAL LUMBER SUPPLEMENTL-5
- Page 13 and 14: ASD STRUCTURAL LUMBER SUPPLEMENTL-7
- Page 15 and 16: ASD STRUCTURAL LUMBER SUPPLEMENTL-9
- Page 17 and 18: ASD STRUCTURAL LUMBER SUPPLEMENTL-1
- Page 19 and 20: ASD STRUCTURAL LUMBER SUPPLEMENTL-1
- Page 21 and 22: ASD STRUCTURAL LUMBER SUPPLEMENTL-1
- Page 23 and 24: ASD STRUCTURAL LUMBER SUPPLEMENTL-1
- Page 25: ASD STRUCTURAL LUMBER SUPPLEMENTL-1
- Page 29 and 30: ASD STRUCTURAL LUMBER SUPPLEMENTL-2
- Page 31 and 32: ASD STRUCTURAL LUMBER SUPPLEMENTL-2
- Page 33 and 34: ASD STRUCTURAL LUMBER SUPPLEMENTL-2
- Page 35 and 36: ASD STRUCTURAL LUMBER SUPPLEMENTL-2
- Page 37 and 38: ASD STRUCTURAL LUMBER SUPPLEMENTL-3
- Page 39 and 40: ASD STRUCTURAL LUMBER SUPPLEMENTL-3
- Page 41 and 42: ASD STRUCTURAL LUMBER SUPPLEMENTL-3
- Page 43 and 44: ASD STRUCTURAL LUMBER SUPPLEMENTL-3
- Page 45 and 46: ASD STRUCTURAL LUMBER SUPPLEMENTL-3
- Page 47 and 48: ASD STRUCTURAL LUMBER SUPPLEMENTL-4
- Page 49 and 50: ASD STRUCTURAL LUMBER SUPPLEMENTL-4
- Page 51 and 52: ASD STRUCTURAL LUMBER SUPPLEMENTL-4
- Page 53 and 54: ASD STRUCTURAL LUMBER SUPPLEMENTL-4
- Page 55 and 56: ASD STRUCTURAL LUMBER SUPPLEMENTL-4
- Page 57 and 58: ASD STRUCTURAL LUMBER SUPPLEMENTL-5
- Page 59 and 60: ASD STRUCTURAL LUMBER SUPPLEMENTL-5
- Page 61 and 62: ASD STRUCTURAL LUMBER SUPPLEMENTL-5
- Page 63 and 64: ASD STRUCTURAL LUMBER SUPPLEMENTL-5
- Page 65 and 66: ASD STRUCTURAL LUMBER SUPPLEMENTL-5
- Page 67 and 68: ASD STRUCTURAL LUMBER SUPPLEMENTL-6
- Page 69 and 70: ASD STRUCTURAL LUMBER SUPPLEMENTL-6
- Page 71 and 72: ASD STRUCTURAL LUMBER SUPPLEMENTL-6
- Page 73 and 74: ASD STRUCTURAL LUMBER SUPPLEMENTL-6
- Page 75 and 76: SUPPLEMENTStructural GluedLaminated
- Page 77 and 78:
ASD STRUCTURAL GLUED LAMINATED TIMB
- Page 79 and 80:
ASD STRUCTURAL GLUED LAMINATED TIMB
- Page 81 and 82:
GL-2DESIGNER FLOWCHART1.1 Flowchart
- Page 83 and 84:
GL-4INTRODUCTION TO STRUCTURAL GLUE
- Page 85 and 86:
GL-6INTRODUCTION TO STRUCTURAL GLUE
- Page 87 and 88:
GL-8ALLOWABLE STRESS AND STIFFNESS3
- Page 89 and 90:
GL-10ALLOWABLE STRESS AND STIFFNESS
- Page 91 and 92:
GL-12ALLOWABLE STRESS AND STIFFNESS
- Page 93 and 94:
GL-14DESIGN ADJUSTMENT FACTORS4.1 G
- Page 95 and 96:
GL-16DESIGN ADJUSTMENT FACTORS4.9 V
- Page 97 and 98:
GL-18DESIGN ADJUSTMENT FACTORSTable
- Page 99 and 100:
GL-20DESIGN ADJUSTMENT FACTORSTable
- Page 101 and 102:
GL-22DESIGN ADJUSTMENT FACTORSTable
- Page 103 and 104:
GL-24DESIGN ADJUSTMENT FACTORSTable
- Page 105 and 106:
GL-26DESIGN ADJUSTMENT FACTORSTable
- Page 107 and 108:
GL-28DESIGN ADJUSTMENT FACTORSTable
- Page 109 and 110:
GL-30CAPACITY SELECTION TABLES5.1 G
- Page 111 and 112:
GL-32CAPACITY SELECTION TABLESTable
- Page 113 and 114:
GL-34CAPACITY SELECTION TABLESTable
- Page 115 and 116:
GL-36CAPACITY SELECTION TABLESTable
- Page 117 and 118:
GL-38CAPACITY SELECTION TABLESTable
- Page 119 and 120:
GL-40CAPACITY SELECTION TABLESTable
- Page 121 and 122:
GL-42CAPACITY SELECTION TABLESTable
- Page 123 and 124:
GL-44CAPACITY SELECTION TABLESTable
- Page 125 and 126:
GL-46CAPACITY SELECTION TABLESTable
- Page 127 and 128:
GL-48CAPACITY SELECTION TABLESTable
- Page 129 and 130:
GL-50CAPACITY SELECTION TABLESTable
- Page 131 and 132:
GL-52CAPACITY SELECTION TABLESTable
- Page 133 and 134:
GL-54CAPACITY SELECTION TABLESTable
- Page 135 and 136:
GL-56OTHER CONSIDERATIONS6.1 Genera
- Page 137 and 138:
GL-58OTHER CONSIDERATIONSTable 6.3
- Page 139 and 140:
GL-60OTHER CONSIDERATIONSAMERICAN W
- Page 141 and 142:
GL-62LOAD AND SPAN TABLES7.1 Genera
- Page 143 and 144:
GL-64LOAD AND SPAN TABLES7.2 Load-S
- Page 145 and 146:
GL-66LOAD AND SPAN TABLESTable 7.2A
- Page 147 and 148:
GL-68LOAD AND SPAN TABLESTable 7.3A
- Page 149 and 150:
GL-70LOAD AND SPAN TABLESTable 7.4A
- Page 151 and 152:
GL-72LOAD AND SPAN TABLESTable 7.5A
- Page 153 and 154:
GL-74LOAD AND SPAN TABLESTable 7.6A
- Page 155 and 156:
GL-76LOAD AND SPAN TABLESAMERICAN W
- Page 157 and 158:
GL-78DESIGN EXAMPLES8.1 GeneralGene
- Page 159 and 160:
GL-80SECTION PROPERTIES9.1 Cross Se
- Page 161 and 162:
GL-82SECTION PROPERTIESTable 9.1(Co
- Page 163 and 164:
GL-84SECTION PROPERTIESTable 9.1(Co
- Page 165 and 166:
GL-86SECTION PROPERTIESTable 9.1(Co
- Page 167 and 168:
GL-88SECTION PROPERTIESTable 9.2(Co
- Page 169 and 170:
GL-90SECTION PROPERTIESTable 9.2(Co
- Page 171 and 172:
GL-92SECTION PROPERTIESTable 9.2(Co
- Page 173 and 174:
SUPPLEMENTTimber Polesand PilesASDA
- Page 175 and 176:
ASD WOOD TIMBER FRAME POLES CONSTRU
- Page 177 and 178:
ASD WOOD TIMBER FRAME POLES CONSTRU
- Page 179 and 180:
ASD TIMBER POLES AND PILES SUPPLEME
- Page 181 and 182:
ASD TIMBER POLES AND PILES SUPPLEME
- Page 183 and 184:
ASD TIMBER POLES AND PILES SUPPLEME
- Page 185 and 186:
ASD TIMBER POLES AND PILES SUPPLEME
- Page 187 and 188:
ASD TIMBER POLES AND PILES SUPPLEME
- Page 189 and 190:
ASD TIMBER POLES AND PILES SUPPLEME
- Page 191 and 192:
ASD TIMBER POLES AND PILES SUPPLEME
- Page 193 and 194:
ASD TIMBER POLES AND PILES SUPPLEME
- Page 195 and 196:
ASD TIMBER POLES AND PILES SUPPLEME
- Page 197 and 198:
ASD TIMBER POLES AND PILES SUPPLEME
- Page 199 and 200:
ASD TIMBER POLES AND PILES SUPPLEME
- Page 201 and 202:
ASD TIMBER POLES AND PILES SUPPLEME
- Page 203 and 204:
ASD TIMBER POLES AND PILES SUPPLEME
- Page 205 and 206:
ASD TIMBER POLES AND PILES SUPPLEME
- Page 207 and 208:
ASD TIMBER POLES AND PILES SUPPLEME
- Page 209 and 210:
ASD TIMBER POLES AND PILES SUPPLEME
- Page 211 and 212:
SUPPLEMENTWood StructuralPanelsASDA
- Page 213 and 214:
ASD WOOD STRUCTURAL PANELS SUPPLEME
- Page 215 and 216:
ASD WOOD STRUCTURAL PANELS SUPPLEME
- Page 217 and 218:
ASD WOOD STRUCTURAL PANELS SUPPLEME
- Page 219 and 220:
SP-2DESIGNER FLOWCHART1.1 Flowchart
- Page 221 and 222:
SP-4INTRODUCTION TO WOOD STRUCTURAL
- Page 223 and 224:
SP-6INTRODUCTION TO WOOD STRUCTURAL
- Page 225 and 226:
SP-8INTRODUCTION TO WOOD STRUCTURAL
- Page 227 and 228:
SP-10DESIGN CAPACITIES3.1 GeneralPa
- Page 229 and 230:
SP-12DESIGN CAPACITIESShear Through
- Page 231 and 232:
SP-14DESIGN CAPACITIESTable 3.2Pane
- Page 233 and 234:
SP-16DESIGN CAPACITIESTable 3.3Pane
- Page 235 and 236:
SP-18DESIGN CAPACITIESTable 3.4.1Ad
- Page 237 and 238:
SP-20DESIGN ADJUSTMENT FACTORS4.1 G
- Page 239 and 240:
SP-22DESIGN ADJUSTMENT FACTORS4.8 P
- Page 241 and 242:
SP-24SECTION PROPERTIES5.1 GeneralS
- Page 243 and 244:
SP-26OTHER CONSIDERATIONS6.1 Fasten
- Page 245 and 246:
SP-28OTHER CONSIDERATIONS• Volunt
- Page 247 and 248:
SP-30SUPPLEMENTAL DESIGN ASSISTANCE
- Page 249 and 250:
SP-32SUPPLEMENTAL DESIGN ASSISTANCE
- Page 251 and 252:
SP-34SUPPLEMENTAL DESIGN ASSISTANCE
- Page 253 and 254:
SP-36SUPPLEMENTAL DESIGN ASSISTANCE
- Page 255 and 256:
SP-38SUPPLEMENTAL DESIGN ASSISTANCE
- Page 257 and 258:
SUPPLEMENTWood StructuralPanel Shea
- Page 259 and 260:
ASD WOOD STRUCTURAL WOOD PANEL FRAM
- Page 261 and 262:
ASD WOOD STRUCTURAL WOOD PANEL FRAM
- Page 263 and 264:
ASD WOOD STRUCTURAL PANEL SHEAR WAL
- Page 265 and 266:
ASD WOOD STRUCTURAL PANEL SHEAR WAL
- Page 267 and 268:
ASD WOOD STRUCTURAL PANEL SHEAR WAL
- Page 269 and 270:
ASD WOOD STRUCTURAL PANEL SHEAR WAL
- Page 271 and 272:
ASD WOOD STRUCTURAL PANEL SHEAR WAL
- Page 273 and 274:
ASD WOOD STRUCTURAL PANEL SHEAR WAL
- Page 275 and 276:
ASD WOOD STRUCTURAL PANEL SHEAR WAL
- Page 277 and 278:
ASD WOOD STRUCTURAL PANEL SHEAR WAL
- Page 279 and 280:
ASD WOOD STRUCTURAL PANEL SHEAR WAL
- Page 281 and 282:
ASD WOOD STRUCTURAL PANEL SHEAR WAL
- Page 283 and 284:
ASD WOOD STRUCTURAL PANEL SHEAR WAL
- Page 285 and 286:
ASD WOOD STRUCTURAL PANEL SHEAR WAL
- Page 287 and 288:
ASD WOOD STRUCTURAL PANEL SHEAR WAL
- Page 289 and 290:
ASD WOOD STRUCTURAL PANEL SHEAR WAL
- Page 291 and 292:
ASD WOOD STRUCTURAL PANEL SHEAR WAL
- Page 293 and 294:
ASD WOOD STRUCTURAL PANEL SHEAR WAL
- Page 295 and 296:
ASD WOOD STRUCTURAL PANEL SHEAR WAL
- Page 297 and 298:
ASD WOOD STRUCTURAL PANEL SHEAR WAL
- Page 299 and 300:
ASD WOOD STRUCTURAL PANEL SHEAR WAL