Displacement Sensors from the OD Series
Displacement Sensors from the OD Series
Displacement Sensors from the OD Series
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>OD</strong>Technical data<strong>OD</strong>30-04P142 1)P840 2) 30-04N142 1)N840 2) 100-35P142 1)P840 2) 100-35N142 1)N840 2) 130-50P142 1)P840 2) 130-50N142 1)N840 2) 250-150 250-150P142 1) N142 1)P840 2) N840 2)Measuring range30 mm ± 4 mm100 mm ± 35 mm130 mm ± 50 mm250 mm ± 150 mmLight source Laser Klasse 2 IEC 60825: 1998Analog outputControl output 3)4–20 mA , 0–300 ΩPNP; 30 V/100 mA Open collectorNPN; 30 V/100 mA Open collectorAccuracy ± 2 % FS 4) /90% – 6%±3% FS 4) /90 % – 18 %Linearity ± 0,5 % FS 4) /90% – 6%±1,5% FS 4) /90% – 6%±3% FS 4) /90 % – 18 %Drift ± 0,02 %/°C FS 4)Resolution of analog output 5)10/3/1 µm, 1/10/100 ms150/50/15 µm, 1/10/100 ms200/70/20 µm, 1/10/100 ms1500/500/150 µm, 1/10/100 msAnalog output freq. response – 3 dB 100 ms – 5/s, 10 ms – 42/s, 1 ms – 720/sTeach-in input (TI)Hold input (SH)TimerVDE protection classSensitivity to ambient lightNPN LOW = active, PNP HIGH = activeNPN LOW = active, PNP HIGH = active40 ms off delayIII10000 lx (sun), 3000 lx (artificial light)Supply voltage V S12–24 V DC, –5 %/+10 %Power consumption 6) 75 mA (at 24 V)Warmup time 7)10 min. maximumEMC EN 50081-2, EN 50082-2Enclosure rating IP 67Circuit protection 8)A, B, DAmbient temperature T A9)Operation: –10 ... +40 °CHousing1)Connection: cable 2 m2)Connection: Plug 2 m pre-fabricatedcable, Order no. 6 020 663,3)Minimum teachable distance window is4 ... 10 times resolution of analog outputStorage: –20 ... +60 °CPBT (housing), Glass (window)4)FS = Full Scale = 8 mm/<strong>OD</strong> 30,80 mm/<strong>OD</strong> 100, 100 mm/<strong>OD</strong> 130,300 mm/<strong>OD</strong> 2505)90 % remission6)Without load7)For applications with <strong>the</strong> highestresolution and preciseness8)A = inputs and outputs reverse-polarityprotectedB = outputs protected against shortcircuitsD = pulse interference suppression9)Do not bend cable at temperatureslower than 0 °C<strong>OD</strong> 30-04: Deviation/lightspot diameterDeviation [%]322 18 %116 %0-13 90 %-2-326 28 30 32 34Distance [mm]SensorØ 0.1 mmØ 0.15 mm Ø 0.15 mm26 30Distance [mm]1 Deviation on black 2 Deviation on grey 3 Deviation on white<strong>OD</strong> 130-50: Deviation/lightspot diameterDeviation [%]32103 90 %-1-2-380 105 130Distance [mm]121556 %18 %180Sensor80 130Distance [mm]340.5 x 1.5 mm0.5 x 2 mm 0.5 x 1.5 mm180<strong>OD</strong> 100-35: Deviation/lightspot diameterDeviation [%]3213 90 %0-12-218 %-365 82,5 100Distance [mm]16 %117,5135Sensor0.5 x 1.2 mm0.5 x 2 mm 0.5 x 1 mm65 100Distance [mm]1351 Deviation on black 2 Deviation on grey 3 Deviation on white<strong>OD</strong> 250-150: Deviation/lightspot diameterDeviation [%]6422 18 %0-2-43 90 %-6150 200 250Distance [mm]16 %300400Sensor0.5 x 2 mm0.5 x 2.5 mm 1 x 3 mm150 250Distance [mm]400Ordering informationTypeOrder no.<strong>OD</strong> 30-04P142 6 021 839<strong>OD</strong> 30-04P840 6 021 841<strong>OD</strong> 30-04N142 6 021 840<strong>OD</strong> 30-04N840 6 021 842<strong>OD</strong> 100-35P142 6 022 476<strong>OD</strong> 100-35P840 6 022 478<strong>OD</strong> 100-35N142 6 022 477<strong>OD</strong> 100-35N840 6 022 479<strong>OD</strong> 130-50P142 6 021 847<strong>OD</strong> 130-50P840 6 021 849<strong>OD</strong> 130-50N142 6 021 848<strong>OD</strong> 130-50N840 6 021 850<strong>OD</strong> 250-150P142 6 021 851<strong>OD</strong> 250-150P840 6 021 853<strong>OD</strong> 250-150N142 6 021 852<strong>OD</strong> 250-150N840 6 021 8541 Deviation on black 2 Deviation on grey 3 Deviation on white 1 Deviation on black 2 Deviation on grey 3 Deviation on white9