13.07.2015 Views

Displacement Sensors from the OD Series

Displacement Sensors from the OD Series

Displacement Sensors from the OD Series

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Displacement</strong> <strong>Sensors</strong> <strong>from</strong> <strong>the</strong> <strong>OD</strong> <strong>Series</strong>Measuring ranges 30± 4100± 35/130± 50250± 150mm<strong>Displacement</strong> SensorDimension illustration<strong>OD</strong> 30 <strong>OD</strong> 100 <strong>OD</strong> 130 <strong>OD</strong> 25020.45042.4 3.84.3822.26043.251.4ø 4.5891Setting options<strong>OD</strong> 30-04P142<strong>OD</strong> 30-04P840<strong>OD</strong> 30-04N142<strong>OD</strong> 30-04N840<strong>OD</strong> 100-35P142<strong>OD</strong> 100-35P840<strong>OD</strong> 100-35N142<strong>OD</strong> 100-35N840DISTANCEOUT STAB.TEACH34<strong>OD</strong> 130-50P142<strong>OD</strong> 130-50P840<strong>OD</strong> 130-50N142<strong>OD</strong> 130-50N840<strong>OD</strong> 250-150P142<strong>OD</strong> 250-150P840<strong>OD</strong> 250-150N142<strong>OD</strong> 250-150N840123456789Teach-in indicator/output indicatorResponse time selectorDistance indicatorStable indicatorTeach-in buttonMode selectorSensitivity selectorMounting hole, ø 4.5 mmConnecting cable 2 m (optional 5 m)or M 12 plug; 90° rotatable52TEACHRUNOFF D.10 ms1 msSET100 msFIXSETOFFSETRUNAUTO67RESPONSE SENS.Connection type<strong>OD</strong> 30-04P142<strong>OD</strong> 30-04N142<strong>OD</strong> 100-35P142<strong>OD</strong> 100-35N142<strong>OD</strong> 130-50P142<strong>OD</strong> 130-50N142<strong>OD</strong> 250-150P142<strong>OD</strong> 250-150N142<strong>OD</strong> 30-04P840<strong>OD</strong> 30-04N840<strong>OD</strong> 100-35P840<strong>OD</strong> 100-35N840<strong>OD</strong> 130-50P840<strong>OD</strong> 130-50N840<strong>OD</strong> 250-150P840<strong>OD</strong> 250-150N840Accessories<strong>OD</strong>C evaluation unitCable receptacle with cable8 SENSICK6 x 0.2 mm 2brngrawhtblkpnkblu(shield)12–24 V DC/L+SHQ AQTI0 V/M8-pin, M 12brn 1 12–24 V DC/L+whtblublkgrapnk23456Q A0 V/MQSHTIvio 7N.C.ora 8N.C.(shield)


<strong>OD</strong>Technical data<strong>OD</strong>30-04P142 1)P840 2) 30-04N142 1)N840 2) 100-35P142 1)P840 2) 100-35N142 1)N840 2) 130-50P142 1)P840 2) 130-50N142 1)N840 2) 250-150 250-150P142 1) N142 1)P840 2) N840 2)Measuring range30 mm ± 4 mm100 mm ± 35 mm130 mm ± 50 mm250 mm ± 150 mmLight source Laser Klasse 2 IEC 60825: 1998Analog outputControl output 3)4–20 mA , 0–300 ΩPNP; 30 V/100 mA Open collectorNPN; 30 V/100 mA Open collectorAccuracy ± 2 % FS 4) /90% – 6%±3% FS 4) /90 % – 18 %Linearity ± 0,5 % FS 4) /90% – 6%±1,5% FS 4) /90% – 6%±3% FS 4) /90 % – 18 %Drift ± 0,02 %/°C FS 4)Resolution of analog output 5)10/3/1 µm, 1/10/100 ms150/50/15 µm, 1/10/100 ms200/70/20 µm, 1/10/100 ms1500/500/150 µm, 1/10/100 msAnalog output freq. response – 3 dB 100 ms – 5/s, 10 ms – 42/s, 1 ms – 720/sTeach-in input (TI)Hold input (SH)TimerVDE protection classSensitivity to ambient lightNPN LOW = active, PNP HIGH = activeNPN LOW = active, PNP HIGH = active40 ms off delayIII10000 lx (sun), 3000 lx (artificial light)Supply voltage V S12–24 V DC, –5 %/+10 %Power consumption 6) 75 mA (at 24 V)Warmup time 7)10 min. maximumEMC EN 50081-2, EN 50082-2Enclosure rating IP 67Circuit protection 8)A, B, DAmbient temperature T A9)Operation: –10 ... +40 °CHousing1)Connection: cable 2 m2)Connection: Plug 2 m pre-fabricatedcable, Order no. 6 020 663,3)Minimum teachable distance window is4 ... 10 times resolution of analog outputStorage: –20 ... +60 °CPBT (housing), Glass (window)4)FS = Full Scale = 8 mm/<strong>OD</strong> 30,80 mm/<strong>OD</strong> 100, 100 mm/<strong>OD</strong> 130,300 mm/<strong>OD</strong> 2505)90 % remission6)Without load7)For applications with <strong>the</strong> highestresolution and preciseness8)A = inputs and outputs reverse-polarityprotectedB = outputs protected against shortcircuitsD = pulse interference suppression9)Do not bend cable at temperatureslower than 0 °C<strong>OD</strong> 30-04: Deviation/lightspot diameterDeviation [%]322 18 %116 %0-13 90 %-2-326 28 30 32 34Distance [mm]SensorØ 0.1 mmØ 0.15 mm Ø 0.15 mm26 30Distance [mm]1 Deviation on black 2 Deviation on grey 3 Deviation on white<strong>OD</strong> 130-50: Deviation/lightspot diameterDeviation [%]32103 90 %-1-2-380 105 130Distance [mm]121556 %18 %180Sensor80 130Distance [mm]340.5 x 1.5 mm0.5 x 2 mm 0.5 x 1.5 mm180<strong>OD</strong> 100-35: Deviation/lightspot diameterDeviation [%]3213 90 %0-12-218 %-365 82,5 100Distance [mm]16 %117,5135Sensor0.5 x 1.2 mm0.5 x 2 mm 0.5 x 1 mm65 100Distance [mm]1351 Deviation on black 2 Deviation on grey 3 Deviation on white<strong>OD</strong> 250-150: Deviation/lightspot diameterDeviation [%]6422 18 %0-2-43 90 %-6150 200 250Distance [mm]16 %300400Sensor0.5 x 2 mm0.5 x 2.5 mm 1 x 3 mm150 250Distance [mm]400Ordering informationTypeOrder no.<strong>OD</strong> 30-04P142 6 021 839<strong>OD</strong> 30-04P840 6 021 841<strong>OD</strong> 30-04N142 6 021 840<strong>OD</strong> 30-04N840 6 021 842<strong>OD</strong> 100-35P142 6 022 476<strong>OD</strong> 100-35P840 6 022 478<strong>OD</strong> 100-35N142 6 022 477<strong>OD</strong> 100-35N840 6 022 479<strong>OD</strong> 130-50P142 6 021 847<strong>OD</strong> 130-50P840 6 021 849<strong>OD</strong> 130-50N142 6 021 848<strong>OD</strong> 130-50N840 6 021 850<strong>OD</strong> 250-150P142 6 021 851<strong>OD</strong> 250-150P840 6 021 853<strong>OD</strong> 250-150N142 6 021 852<strong>OD</strong> 250-150N840 6 021 8541 Deviation on black 2 Deviation on grey 3 Deviation on white 1 Deviation on black 2 Deviation on grey 3 Deviation on white9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!