13.07.2015 Views

Proposed Permit to Operate - Air Pollution Control District

Proposed Permit to Operate - Air Pollution Control District

Proposed Permit to Operate - Air Pollution Control District

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

COUNTY OF SAN DIEGO, AIR POLLUTION CONTROL DISTRICT10124 OLD GROVE RD, SAN DIEGO, CA 92131(858) 586-2600 FAX (858) 586-2601 PERMIT NO.961422EXPIRESJune 15, 2016PERMIT TO OPERATETHE FOLLOWING IS HEREBY GRANTED A PERMIT TO OPERATE THE ARTICLE, MACHINE, EQUIPMENT OR CONTRIVANCE DESCRIBED BELOW. THISPERMIT IS NOT TRANSFERABLE TO A NEW OWNER NOR IS IT VALID FOR OPERATION OF THE EQUIPMENT AT ANOTHER LOCATION, EXCEPT FORPORTABLE EQUIPMENT. RULE 10C REQUIRES THIS PERMIT TO OPERATE OR COPY BE POSTED ON OR WITHIN 25 FEET OF THE EQUIPMENT, ORMAINTAINED READILY AVAILABLE AT ALL TIMES ON THE OPERATING PREMISES.PERMITTEEEQUIPMENT ADDRESSNATIONAL STEEL & SHIPBUILDING2798 HARBOR DRIVE MS 22-A 2798 HARBOR DRIVESAN DIEGO, CA 92113-0000 SAN DIEGO, CA 92113EQUIPMENT DESCRIPTIONCRANE #8: CATERPILLAR, MODEL C-15, 563 BHP, DIESEL FIRED, TURBOCHARGED, AFTERCOOLED, S/N TBD,ENGINE FAMILY NO. 8CPXL08.8ESK, VENTED TO A JOHNSON MATTHEY CRT DIESEL PARTICULATE FILTEREVERY PERSON WHO OWNS OR OPERATES THIS EQUIPMENT IS REQUIRED TO COMPLY WITH THE CONDITIONSLISTED BELOW AND ALL APPLICABLE REQUIREMENTS AND DISTRICT RULES, INCLUDING BUT NOT LIMITED TORULE(S) 50, 53, 62, AND 69.4.1.FAILURE TO OPERATE IN COMPLIANCE IS A MISDEMEANOR AND IS SUBJECT TO CIVIL AND CRIMINAL PENALTIES.A. FEDERALLY-ENFORCEABLE AND DISTRICT-ENFORCEABLE CONDITIONS1. THE PERMITTEE SHALL COMPLY WITH THE FOLLOWING APPLICABLE REQUIREMENTS: RULE 53 ANDRULE 62.[RULE 1421]2. THIS EQUIPMENT SHALL BE PROPERLY MAINTAINED AND KEPT IN GOOD OPERATING CONDITION AT ALLTIMES IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. THESE INSTRUCTIONS SHALL BE KEPTONSITE.[RULE 69.4.1]3. THIS EQUIPMENT SHALL BE FIRED ON CALIFORNIA DIESEL FUEL ONLY.[RULE 69.4.1]4. THE PERMITTEE SHALL MAINTAIN CALIFORNIA DIESEL FUEL CERTIFICATION TO SUBSTANTIATE THEUSE OF THIS FUEL. THESE RECORDS SHALL BE MAINTAINED ONSITE FOR FIVE YEARS AND MADEAVAILABLE TO THE DISTRICT UPON REQUEST.[RULE 69.4.1]5. A NON-RESETTABLE ENGINE HOUR METER SHALL BE INSTALLED ON THIS ENGINE, MAINTAINED INGOOD WORKING ORDER, AND USED FOR RECORDING ENGINE OPERATING HOURS. IF A METER ISREPLACED, THE AIR POLLUTION CONTROL DISTRICT’S COMPLIANCE DIVISION SHALL BE NOTIFIEDWITHIN 10 CALENDAR DAYS. THE WRITTEN NOTIFICATION SHALL INCLUDE THE FOLLOWINGINFORMATION:A. OLD METER’S HOUR READING;B. REPLACEMENT METER’S MANUFACTURER NAME, MODEL AND SERIAL NUMBER, IF AVAILABLE, ANDCURRENT HOUR READING ON REPLACEMENT METER; ANDC. COPY OF RECEIPT OF RECEIPT OF NEW METER OR OF INSTALLATION WORK ORDER. A COPY OFTHE METER REPLACEMENT NOTIFICATION SHALL BE MAINTAINED ONSITE AND MADE AVAILABLE TOTHE AIR POLLUTION CONTROL DISTRICT UPON REQUEST.[RULE 69.4.1]6. ENGINE OPERATION SHALL NOT EXCEED 6363 HOURS PER CALENDAR YEAR. THE OWNER OROPERATOR OF THIS ENGINE SHALL MAINTAIN A MONTHLY OPERATING LOG CONTAINING, AT AMINIMUM, DATES AND TIMES OF ENGINE OPERATION.[NSR]7. THE DIESEL PARTICULATE FILTER SHALL BE MAINTAINED IN GOOD CONDITION AND IN FULLOPERATION AT ALL TIMES WHEN THE ENGINE IS IN OPERATION.[STATIONARY DIESEL ENGINE ATCM]8. DIESEL PARTICULATE FILTER BACKPRESSURE SHALL NOT EXCEED THE HIGH BACKPRESSURE LIMITOF 32.4 INCHES OF WATER. THE RED WARNING LIGHT SHALL BE SET AT A MAXIMUM OF 32.4 INCHESOF WATER COLUMN. DOCUMENTATION OF THE SETTINGS FOR EACH WARNING LIGHT SHALL BEMAINTAINED WITH THE EQUIPMENT.[STATIONARY DIESEL ENGINE ATCM]9. THE ENGINE MUST BE IMMEDIATELY SHUTDOWN AND CORRECTIVE ACTION SHALL BE TAKEN WHENTHE HIGH BACKPRESSURE LIMIT IS REACHED.[STATIONARY DIESEL ENGINE ATCM]<strong>Permit</strong> Conditions Continued...Page 1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!