13.07.2015 Views

Proposed Permit to Operate - Air Pollution Control District

Proposed Permit to Operate - Air Pollution Control District

Proposed Permit to Operate - Air Pollution Control District

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

COUNTY OF SAN DIEGO, AIR POLLUTION CONTROL DISTRICT10124 OLD GROVE RD, SAN DIEGO, CA 92131(858) 586-2600 FAX (858) 586-2601 PERMIT NO.961424EXPIRESJune 15, 2016PERMIT TO OPERATETHE FOLLOWING IS HEREBY GRANTED A PERMIT TO OPERATE THE ARTICLE, MACHINE, EQUIPMENT OR CONTRIVANCE DESCRIBED BELOW. THISPERMIT IS NOT TRANSFERABLE TO A NEW OWNER NOR IS IT VALID FOR OPERATION OF THE EQUIPMENT AT ANOTHER LOCATION, EXCEPT FORPORTABLE EQUIPMENT. RULE 10C REQUIRES THIS PERMIT TO OPERATE OR COPY BE POSTED ON OR WITHIN 25 FEET OF THE EQUIPMENT, ORMAINTAINED READILY AVAILABLE AT ALL TIMES ON THE OPERATING PREMISES.PERMITTEEEQUIPMENT ADDRESSNATIONAL STEEL & SHIPBUILDINGPO BOX 85278 MS 20 J28TH ST & HARBOR DRSAN DIEGO, CA 92186-5278 SAN DIEGO, CA 92113EQUIPMENT DESCRIPTIONCRANE #9: CUMMINS, MODEL QSX15-G9 NR2, 680 BHP, DIESEL FIRED, TURBOCHARGED, AFTERCOOLED,S/N 79093287, ENGINE FAMILY NO. 5CEXL015.AAB, VENTED TO A DIESEL PARTICULATE FILTEREVERY PERSON WHO OWNS OR OPERATES THIS EQUIPMENT IS REQUIRED TO COMPLY WITH THE CONDITIONSLISTED BELOW AND ALL APPLICABLE REQUIREMENTS AND DISTRICT RULES, INCLUDING BUT NOT LIMITED TORULE(S) 50, 53, 62, AND 69.4.1.FAILURE TO OPERATE IN COMPLIANCE IS A MISDEMEANOR AND IS SUBJECT TO CIVIL AND CRIMINAL PENALTIES.A. FEDERALLY-ENFORCEABLE AND DISTRICT-ENFORCEABLE CONDITIONS1. THE PERMITTEE SHALL COMPLY WITH THE FOLLOWING APPLICABLE REQUIREMENTS: RULE 53 ANDRULE 62.[RULE 1421]2. THIS EQUIPMENT SHALL BE PROPERLY MAINTAINED AND KEPT IN GOOD OPERATING CONDITION AT ALLTIMES IN ACCORDANCE WITH MANUFACTURER’S INSTRUCTIONS. THES INSTRUCTIONS SHALL BE KEPTONSITE.[RULE 69.4.1]3. AN ENGINE IDENTICAL TO THE ONE DESCRIBED ABOVE WITH SERIAL NO. 79221158 MAY BE USEDDURING TIMES WHEN THE ENGINE DESCRIBED ABOVE IS UNDERGOING MAINTENANCE. AT NO TIMESHALL THE ENGINE WITH SERIAL NO. 79221158 BE OPERATED WHEN ALL FOUR ENGINES DESCRIBEDIN PERMIT TO OPERATE NOS. 961424, 961425, 950705 AND 950704 ARE IN OPERATION.[NSR]4. THIS EQUIPMENT SHALL BE FIRED ON CALIFORNIA DIESEL FUEL ONLY.[RULE 69.4.1]5. THE PERMITTEE SHALL MAINTAIN CALIFORNIA DIESEL FUEL CERTIFICATION TO SUBSTANTIATE THEUSE OF THIS FUEL. THESE RECORDS SHALL BE MAINTAINED ONSITE FOR TWO YEARS AND MADEAVAILABLE TO THE DISTRICT UPON REQUEST.[RULE 69.4.1]6. THE DIESEL PARTICULATE FILTER SHALL BE MAINTAINED IN GOOD CONDITION AND IN FULLOPERATION AT ALL TIMES WHEN THE ENGINE IS IN OPERATION.[DIESEL ATCM]7. DIESEL PARTICULATE FILTER BACKPRESSURE SHALL NOT EXCEED THE HIGH BACKPRESSURE LIMITOF 32.4 INCHES OF WATER (81.1 MILLIBARS). THE RED WARNING LIGHT SHALL BE SET AT A MAXIMUMOF 32.4 INCHES OF WATER COLUMN. DOCUMENTATION OF THE SETTINGS FOR EACH WARNING LIGHTSHALL BE MAINTAINED WITH THE EQUIPMENT.[DIESEL ATCM]8. THE ENGINE MUST BE IMMEDIATELY SHUTDOWN AND CORRECTIVE ACTION SHALL BE TAKEN WHENTHE HIGH BACKPRESSURE LIMIT IS REACHED.[DIESEL ATCM]9. THE ENGINE SHALL BE EQUIPPED WITH A DEVICE THAT ALERTS THE OWNER OR OPERATOR PRIORTO THE HIGH BACKPRESSURE LIMIT BEING REACHED.[DIESEL ATCM]10. A DAILY LOG INDICATION OF FUEL CONSUMPTION OF THE ENGINE SHALL BE MAINTAINED ON THEPREMISES.[NSR]11. PERMITTEE SHALL MONITOR ALL OPERATING PARAMETERS RECOMMENDED BY THE ENGINEMANUFACTURER.[RULE 69.4.1, DIESEL ATCM]12. A NON-RESETTABLE FUEL METER SHALL BE INSTALLED AND MAINTAINED IN GOOD WORKING ORDERAND USED FOR RECORDING TOTAL FUEL USAGE OF ANY ENGINE USED IN THIS CRANE. THE<strong>Permit</strong> Conditions Continued...Page 1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!